Gebruiksaanwijzing /service van het product R Class Conversion to WES7 van de fabrikant Wyse
Ga naar pagina of 18
Inst allation Guide Wyse ® R Class Conversion to WES7 Wyse ® USB Firmware T ool TM Release 1.10 Issue: 102910 PN: 883887-18L Rev . B.
Copyright Notices © 2010, Wyse T echnology Inc. All right s reserved. This manual and the software and firmware described in it are copyrighted. Y ou may not rep roduce, transmit, transcribe, store i.
Content s 1 Introduction 1 Kit Contents 1 Overview 2 Wyse T echnical Support 2 Related Document ation and Services 2 Wyse Online Community 2 2 Inst alling R90L Thin Client Flash and RAM 3 Requirements.
iv Contents This page intentionally blank..
1 Introduction This guide provides ste p-by-step in structions to c onvert R90L thin clients from XPe to WES7. Caution WES7 firmware requires R class thin clients to h ave a minimum of 4 GB fla sh and 2 GB RAM. Tip After conv erting your thin clie nts, obtain a ny available firmwar e update a t http://www .
2 Chapter 1 The Conversion Sof tware Assembly DVD-ROM conta ins: • A PDF of this Reference Guide • Wyse USB Firmware T ool Release 1.10 • R Class WES7 Conversion Ima ge folder contain ing the following files: · bios.img · cmos.img · commandsXml.
2 Inst alling R90L Thin Client Flash and RAM This chapter cont ains information for users of Wyse R90L thin client s who must install new flash and RAM. If you are inst alling firmware only , you can sk ip this chapte r and proceed to"Installing WES7 Firmware.
4 Chapter 2 Procedures S tep 1: Remove the R90L Thin Client Left Side Cover Caution Follow all precautions listed in the Quick- S tart Guide that came with your thin client for disconne cting and reconnecting the thin client.
Installing R90L Thin Client Flash and RAM 5 S tep 2: Install the R90L Flash Module Wa r n i n g Flash modules may be susceptible to da mage by Electro-S tatic Discharge (ESD).
6 Chapter 2 S tep 3: Install the R90L RAM Module Wa r n i n g RAM modules may be susceptible to damage by Electro-S t atic Discharge (ESD). All industry-st andard cautions should be fo llowed to avoid ESD.
3 Inst alling WES7 Firmware This chapter include s the requirement s and procedures you nee d to install and use Wyse ® USB Firmware T ool TM to update your thin c lient to WE S7 firmware.
8 Chapter 3 S tep 3: Use Wyse USB Firmware T ool to Config ure a Single USB Key to Inst all Firmware 1. Double-click the shortcu t to run the tool an d open the Wyse USB Firmware T o ol wizard (the welcome p age provides the p roduct version and descriptio n, and a link to view the Wyse end user license agreemen t).
Installing WES7 Firmware 9 4. Select the Windows Embedded S t andard 7 OS type o ption. 5. Select the Up date Firmware operation to perform optio n. Tip Although the Preserve dat a p artition check bo.
10 Chapter 3 Figure 12 Prep are USB drive 11 . Select the USB key onto which you want the configurations (you can use Refresh as needed to recogn ize an inserted USB key), and then click Next . The pr ogress bar s show the ov erall prog ress and task pr ogress.
Installing WES7 Firmware 11 S tep 5: V erifying Thin Client Operation After the thin client reboo ts, you can ver ify the Ve r s i o n and that your general client information is cor rect.
12 Chapter 3 S tep 6: Attach a Wyse Conversion Label and Microso ft License Label on Each Converted Thin Client The conversion kit is suppl ied with Wyse Conversion Labels and Microsof t License Labels that must be atta ched to each thin client as shown in Figure 14.
Installing WES7 Firmware 13 T roubleshooting This section contains ge neral troubleshooting information . USB Keys - T roubleshoot ing Boot Issues Due to differ ent manufacturing proce sses on U SB keys (and the variety of them), not all brands have been tested with the Wyse USB Firmware T ool.
Inst allation Guide Wys e ® R Class Conversion to WES7 Issue: 1029 10 Written and publishe d by: Wyse T echnology Inc., October 2010 Created using FrameMake r ® and Acrobat ®.
Een belangrijk punt na aankoop van elk apparaat Wyse R Class Conversion to WES7 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Wyse R Class Conversion to WES7 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Wyse R Class Conversion to WES7 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Wyse R Class Conversion to WES7 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Wyse R Class Conversion to WES7 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Wyse R Class Conversion to WES7 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Wyse R Class Conversion to WES7 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Wyse R Class Conversion to WES7 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.