Gebruiksaanwijzing /service van het product 400 PLUS van de fabrikant Xantrex Technology
Ga naar pagina of 52
Owner’s Guide XPower Inverter 175 PLUS 400 PLUS 700 PLUS t 1-800-670-0707 (toll free) t 604-422-2777 f 604-420-2145 e customerservice@xantrex.com www .
XP ower Inverter 175 Plus , 400 Plus , 700 Plus Owner’ s Manual.
ii About Xantrex Xantrex T echno logy Inc. is a world-leading sup plier of advanced p ower electronics and controls with products fr om 50 watt mobile units to 1 MW utility- scale systems for wind, solar , batteries , fuel ce lls, microturbines and backup power applications in both grid- connec ted and st andalone systems.
iii Disclaimer WITHOUT LIMITING THE GENERALITY OF THE FOREGOING , UNLESS SPECIFICALL Y AGREED TO BY IT IN WRITING , XANTREX a) MAKES NO W ARRANTY AS TO THE ACCURACY , SUFFICIENCY OR SUIT ABILITY OF AN.
iv.
v T able of Content s 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 About the XPower Plus Inverters . . . . . . . . . . . . . . . . 7 About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2. Important Safety Information .
vi 5. Operating the XPower Inverter . . . . . . . . . . . . . . . . 28 Operating Conditions and Guidelines . . . . . . . . . . . . 28 6. Maintaining Battery Condition . . . . . . . . . . . . . . . . 32 7. Troubleshooting . . . . . . . . . . . . . . . .
7 1 Introduction Thank you for purchasing an XPow er Plus Inverter. The XPower 175 Plus, XPower 400 Plus, and XP ower 700 Plus are part of a family of ultra compact and highly portable power inverters from Xantrex T echnology Inc., the leader in high-frequency inverter design.
8 • Low battery alarm • Low voltage sh utdown • High voltage shutdown • Overload shutdown • Over temperature shutdow n • Short circuit protection About This Guide T o get the best performa.
9 2 Import ant Safet y Information Misusing or incorrectly connecting the XPower may damage the equipment or create hazardous conditions for users. Read the following safety instruction s and pay special attention to all Caution and Wa r n i n g statements in the guide.
10 Wa r n i n g ! Heated Surface The XPower housi ng may become uncomfor tably warm, reaching 140° F (60° C) under extended high power operation. Ensure that at least 2 inches (5 cm) of air surround the inverter . During operation, keep it away from materials that may be af fected by high temperatures.
11 Caution! Some chargers for small nickel-cadmium batteries can be damaged if connected to the XPower. Do not use the inverter with the following appliances: • Small battery-operated appliances like rechargeable flashlights , some rechargeable shavers, and night lights that are plugged directly into an AC receptacle to rechar ge.
12 Additional Safety Guidelines • Do not insert foreig n objects in the XPower outlet s. • Never connect the inverter to pow er utility AC distribution wiring. • Do not use the XPower in temperatures over 104° F (40° C). • Do not expose the XP ower to water , rain, snow , or spray .
13 3 XPower Features This section describes the main f eatures of the XPower inverters. AC (Front) Panel Figure 1 shows the AC panel of the XPower 175 Plus invert er .
14 Figure 2 shows the AC panel of the XPower 400 Plus and XPower 700 Plus inverters. Figure 2 AC Panel of XPower 4 00 Plus and XPower 7 00 Plus AC Outlets XPower 175 Plus An AC receptacle is lo cated on one end of the XPower 175 Plus.
15 XPower 400 Plus T wo AC receptacles are located on one end of the XPower 400 Plus. Y ou can plug in any 120-volt appliances with a combined total power co nsumption of 320 watts or less when the inverter is turned on. XPower 700 Plus T wo AC receptacles are located on one end of the XPower 700 Plus.
16 V entilation Openings T o prevent overheating, ensure that the ventilation openings on the front and back panel s are kept clear . DC (Back) Panel Figure 3 shows the DC panel of the XPower 175 Plus invert er .
17 Figure 4 shows the DC panel of the XPower 400 Plus and XPower 700 Plus inverters. Figure 4 DC Panel of XPower 4 00 Plus and XPower 700 Plus Fan and V entilation Openings: The cooling fan on the XPower 400 Plus and XPower 700 Plus units are designed to operate only when output power is greater than approximately 100 watts.
18 Positive and Negative Cabling T erminals: For XPower 400 Plus and XPower 700 Plus, y ou connect the ring terminals on the power cables to these terminal s. T o ensure correct polarity , red must be connected to red and black must be connected to black.
19 Figure 6 Cable for Direct Conne ction to 12 V olt Battery Caution! The XPower 175 Plus can not power loads over 150 watts, so it is not equipped with cabling term inals and can not be run from a 12 volt b attery .
20 Types of Connections Product Lighter Plug Connectio n Cable Clamps/Battery Connection XPower 175 Plus A vailable - A cable is permanently atta ched to the inverter . Figur e 5 . Not A vailab le XPower 400 Plus A vailable - Y ou must connect a separate lighter plug cable (included).
21 4 Connecting the XPower Plus Inverters Choosing a Location For the best performance, place th e inverter on a flat surface in a location that is: Caution! The XPower must o nly be co nnected to a battery that has a nominal output of 12 volts.
22 Dry Do not allow water o r other liquids to splash on the inverter . Cool Ambient temperatures should be between 32° F and 104° F (0° C and 40° C) - the cooler the better within this ra nge.
23 Connecting the XPower 175 Plus and XPower 400 Plus for Loads Under 150 W att s Follow these steps to connect th e XPower 175 Plus or XPower 400 Plus inverter: 1. Place the inverter on a flat surface like the floor of your vehicle. 2. Make sure the On/O ff switch on the front panel is off.
24 4. Place the inverter ’ s lighter plug in the vehicle’ s cigarette lighter socket or a 12 volt outlet. 5. T urn on the front panel On/Off switch. The green POWER light indicates th at the XPower is operating normally and that AC power is available at the outlet.
25 Follow these steps to make a direct battery connection: 1. Place the inverter on a flat surface. 2. Make sure the On/O ff switch on the front panel is off. Wa r n i n g ! Batteries contain corrosive materials and present an electrical shock hazard.
26 3. T ake the cables equipped wi th battery clips on one end ( Figure 6 ) and place the ring terminals over the two cabling terminals on the back of the in verter .
27 4. Fasten the positive (red) clip to the positive battery post, and then fasten the negative (black) clip to the negat ive battery post. 5. T urn on the front panel On/Off switch. The green POWER light indicates that AC power is available at the outlets and that the in verter is operating normally .
28 5 Operating the XPower Inverter This section explains how to operate the XPower 175 Plus, XPower 400 Plus and XPower 700 Plus most efficiently. Operating Conditions and Guidelines This section describes normal operation as well as conditions th at trigger an alarm or automati cally shut down the XPower.
29 Overload Shutdown If you connect an AC load that is rated too high (see T able 1 on page 30) or a load that draws excessive surge power , the XPower shuts down. The red FA U LT light comes on. Over T emperature Shutdown The XPower shuts down automatically if it exceeds its safe ope rating temperature.
30 T able 1 Power and Surge Ratings The inverter ’ s AC (“modified-sine wave”) out put waveform, is designed to function similarly to the sine wave shape of ut ility power . Most AC products correctly rated for the power rating maximums listed above or less w ill operate norm ally with the XPower inverter .
31 Operating Loads With High Surge Requirements The power , or wat tage, rating of AC loads is the average amount of power they use. Some applia nces consume more power than their power rating when they are first turned on . TVs, monito rs, and electric motors are some products that have high surge requirements at start up.
32 6 Maint aining Battery Condition The battery operating ti me of th e XPower depends on the charge level of the battery , battery capacity , and the amount of power drawn by the AC loads you are op erating.
33 battery wil l shorten its li fe. Th erefore, when you are using a vehicle battery as a power so urce, start the vehicle every hour or two to recharge the battery . • The XPower will operate while the engine is ru nning, but the voltage drop that occu rs when th e engine starts may trigger a low voltage shutdown.
34 7 T roubleshooting This section will help you identify the so urce of most problems that can occur with the XPower inverter . If you have a problem with the inverter , please review this section before contacting Xantrex Customer Service.
35 Common Problems Buzz in Audio Systems Some inexpensive stereo systems have inadequate internal power supply filtering and buzz slig htly when powered by the XPower. The best solution is to use an audio system with a goo d quality filter . Wa r n i n g ! Electrical Shock and Burn Hazard Do not dismantle the XPower .
36 Television Interference The XPower is shielded to minimize interference with TV signals. If TV signals are weak , you may see interference in the form of lines scrolling across the screen.
37 The AC load will not operate. No inverter light s are on. Inverter will run some small loads, but not larger ones. Possible Cause Suggested Remedy Battery is defective. Chec k battery and replace if required. The inverter has been connected with reverse DC input polarity .
38 Measured inverter out put is too low . Alarm is sounding. Possible Cause Suggested Remedy A standard “average-reading” AC voltmeter has been used to measure output voltage, resulting in an apparent reading 5-15 volts too low .
39 Battery run time is less than expected. The AC load will not o perate. The F AUL T light is on. Possible Cause Suggested Remedy The AC product power consumption is higher than rated. Use a larger batte ry to make up for the increased power requirement.
40 The AC product(s) connected are rated at less than the inverte r ’ s continuous power rating; high starting surge has caused overload shutdown. The product exceeds the inverter’ s surge capability . Use a product with a starting sur ge power within the XPower’ s capability .
41 8 Specifications Specifications are subject to change without notice. T able 1 XPower Plus S pecifications XPower 175 Plus XPower 400 Plus XPower 700 Plus AC output voltage (nominal) 120 volts AC 1.
42 XPower 175 Plus XPower 400 Plus XPower 700 Plus Efficiency (maximum) 90% 90% 90% Ambient operating temperature range 32° F – 104° F 0° C – 40° C 32° F – 104° F 0° C – 40° C 32° F – 104° F 0° C – 40° C Low battery alarm (nominal) 10.
43 9 Limited W arranty What does this warranty cover and how long does it last? This Limited W arranty is provi ded by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your XPower Plus Inve rter.
44 Period or 90 days from the date of th e return shipment to the customer , whichever is greater . Al l replaced products and all parts removed from repaired products become the property o f Xantrex.
45 Direct returns may be performed according to the Xantrex Return Material Authorization Policy desc ribed in your product manual. For some products, Xantrex maintains a network of reg ional Authorized Service Centers. Ca ll Xantrex or check our webs ite to see if your product can be repaired at one of these facili ties.
46 1. the product if it has been misuse d, neglected, impr operly installed, physically damaged or a ltered, either internally or externally , or damaged from improper use or use in an unsuitable environment; 2.
47 OTHER WISE IN CONNECTION WITH THE P RODUCT , HOWEVER ARISING (WHETHER BY CONTRACT , TOR T , NEGLIGENCE, PRINCIPLES OF MANUF ACTURER’S LIABILITY , OPERA TION OF LA W , CONDUCT , ST A TEMEN T OR OTHER WISE), INCLUDING WITHOUT RESTRICTION ANY IMPLIED W ARRANTY OR CONDITION OF QUALITY , MERCHANT ABILITY OR FITNESS FOR A P AR TICULAR PURPOSE.
48 Exclusions If this product is a consumer produc t, federal law does not allow an exclusion of implied warranties. T o the extent you are entitled to implied warranties under federal law , to the extent permitted by applicable law they are limited to the duration of this Limited W arranty .
49 Return Material Authorization Policy Before returning a product directly to Xantrex you must obtain a Return Material Authorization (RMA) number and the correct factory “Ship T o” address.
50 2. Include the following: • The RMA number supplied by Xant rex T echnology Inc. clearly marked on the ou tside of the box. • A return address where the unit ca n be shipped.
51 Out of Warranty Service If the warranty period for your XPower Plus Inverter has expired, if the inverter was damaged by misuse or incorrect installation, if other conditions of the warranty have no t be en met, or if no dated proof of purchase is available, your inverter may be serv iced or replaced for a flat fee.
Een belangrijk punt na aankoop van elk apparaat Xantrex Technology 400 PLUS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Xantrex Technology 400 PLUS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Xantrex Technology 400 PLUS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Xantrex Technology 400 PLUS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Xantrex Technology 400 PLUS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Xantrex Technology 400 PLUS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Xantrex Technology 400 PLUS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Xantrex Technology 400 PLUS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.