Gebruiksaanwijzing /service van het product CZB018 THRU 060 van de fabrikant York
Ga naar pagina of 20
TECHNICAL GUIDE AFFINITY SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R-410A MODELS: CZB018 THRU 060 (1.5 THRU 5 NOMINAL TONS ) Due to continuous pr od uct improvement, sp eci fications are subject to change without n otice. Visit us on the web at www .
246723-YTG-J-1006 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
246723-YTG-J-1006 Unitary Products Group 3 Additional R-410A Charge / TXV Size f or V arious Matche d Sy stems Out door Unit CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Uni.
246723-YTG-J-1006 4 Unitary Products Group PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrig erant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing. 2. V erify the TXV and additional char ge required for specific evaporator coil in th e system using the above table.
246723-YTG-J-1006 Unitary Products Group 5 COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL ELECTRIC HEA T KW 2 W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 PH 13 SEER AC WITH MA CZB0181 1 MA08B 2,5,8,10 17 FC/MC18B 600 18.
246723-YTG-J-1006 6 Unitary Products Group 1 PH 13 SEER AC WITH AHP/ SHP / F*FP CZB0181 1 AHP18 2,5,8 17 – 600 18.0 12.1 13.00 1 1.00 AHP24 2,5,8,10 17 – 600 18.0 12.3 13.00 1 1.00 F*FP024 5,8,1 0 17 – 600 18.0 12.1 13.00 1 1.00 CZB0241 1 AHP24 2,5,8,10 17 – 800 23.
246723-YTG-J-1006 Unitary Products Group 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1,2 EER TOT AL SENS. CZB0181 1 450 750 14,17 FC/MC/PC/UC18 600 18.
246723-YTG-J-1006 8 Unitary Products Group COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 13 SEER AC WITH V ARIABLE SPEED FURNACES 2 CZB0181 1 PV8*A12 FC/MC/PC24A 14 600 18.
246723-YTG-J-1006 Unitary Products Group 9 CZB0421 1 PV8*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .
246723-YTG-J-1006 10 Unitary Products Group ACCESSORIES* Hard St art Kit (024-31994-000, 024-319 95-000) - Provides increased starting torque for areas w ith low voltage.
246723-YTG-J-1006 Unitary Products Group 11 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), s.
246723-YTG-J-1006 12 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), s.
246723-YTG-J-1006 Unitary Products Group 13 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), s.
246723-YTG-J-1006 14 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), s.
246723-YTG-J-1006 Unitary Products Group 15 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), s.
246723-YTG-J-1006 16 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), s.
246723-YTG-J-1006 Unitary Products Group 17 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), s.
246723-YTG-J-1006 18 Unitary Products Group NOTES.
246723-YTG-J-1006 Unitary Products Group 19 NOTES.
Subject to change without notice. Printe d in U.S.A. 246723-YTG-J-1006 Copyright © by York International/JCI 2006. All righ ts reserved. Supersedes: 246723-YTG-H-0906 Unitary 5005 Norman Product s Y .
Een belangrijk punt na aankoop van elk apparaat York CZB018 THRU 060 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen York CZB018 THRU 060 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens York CZB018 THRU 060 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding York CZB018 THRU 060 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over York CZB018 THRU 060 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van York CZB018 THRU 060 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de York CZB018 THRU 060 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met York CZB018 THRU 060 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.