Gebruiksaanwijzing /service van het product D1EE 048 van de fabrikant York
Ga naar pagina of 16
GENERAL YORK Model DEE units are single package air conditioners designed for outdoor installation on a rooftop or a slab. Electric heaters are available as field-installed accessories. The units are completely assembled on rigid, permanently attached base rails.
035-12046-003-A-0204 2 Unitary Products Group General ................................................................................ 1 Inspection ............................................................................ 1 Reference ..............
LIMIT ATIONS These units must be installed in accordance with the current edition of the following national and local safety codes: In USA: 1. National Electrical Code ANSI/NFP A No. 70. 2. Local electric utility requirements. In Canada: 1. Canadian Electrical Code C22.
kept clean or replaced with same size and type. Dirty filters will reduce the capacity of the unit and will result in frosted coils or safety shutdown. Minimum filter area and required sizes are shown in T able 2. CONDENSA TE DRAIN Plumbing must conform to local codes.
All direct-drive units with 460 and 575 voltage are shipped with the wire labeled #1 16 connected to the “HIGH” speed tap on the blower motor . If the medium speed is required, connect wire #1 16 to the “MED” speed tap and the blue motor lead to the “HIGH” speed tap.
10. T o check that the damper blades move smoothly without binding, carefully turn the minimum position adjusting screw fully clockwise and then energize and de-energize terminals “R” to “G”. With terminals “R” to “G” energized, turn the minimum position screw counterclockwise until the desired minimum position has been attained.
035-12046-003-A-0204 Unitary Products Group 7 FIG. 5 - DIMENSIONS & CLEARANCES - 3 - 5 TONS DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers.
Install the bracket on the left hand side of the unit as shown in Figure 5. Several existing screws at the top of the unit and one screw approximately midway down from the top will be used for mounting the bracket. Screws should be loosened only - NOT REMOVED.
035-12046-003-A-0204 Unitary Products Group 9 T ABLE 4 - SUPPL Y AIR PERFORMANCE - 3 & 4 TON w/Belt-Drive Blower UNIT SIZE (MBH) AIR FLOW CFM Available External Static Pressure - IWG* 0.
035-12046-003-A-0204 10 Unitary Products Group T ABLE 5 - SUPPL Y AIR PERFORMANCE - 5 TON w/Belt-Drive Blower UNIT SIZE (MBH) AIR FLOW CFM Available External Static Pressure - IWG* 0.
035-12046-003-A-0204 Unitary Products Group 11 EXTERNAL ST A TIC PRESSURE DROP DESCRIPTION RESIST ANCE, IWG CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Economizer 1, 3 0.07 0.08 0.09 0.1 1 0.13 0.15 0.17 0.20 0.23 0.26 0.30 Electric Heaters 1 5 - 15 KW 0.
The heaters are wired for a single point power supply . Power supply need only be brought into the single point terminal block and thermostat wiring to the low voltage terminal strip located in the upper portion of the unit control box. Fuses are supplied, where required, by the factory .
HEA T ANTICIP ATOR SETPOINTS It is important that the anticipator setpoint be correct. T oo high of a setting will result in longer heat cycles and a greater temperature swing in the conditioned space.
035-12046-003-A-0204 14 Unitary Products Group SECURE OWNER'S APPROV AL : When the system is functioning properly , secure the owner's approval. Show him the location of all disconnect switches and the thermostat. T each him how to start and stop the unit and how to adjust tem - perature settings within the limitations of the system.
035-12046-003-A-0204 Unitary Products Group 15.
Unitary Products Group 5005 York Drive, Norman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A 035-12046-003-A-0204 Copyright © 2004 by Unitary Products Group.
Een belangrijk punt na aankoop van elk apparaat York D1EE 048 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen York D1EE 048 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens York D1EE 048 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding York D1EE 048 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over York D1EE 048 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van York D1EE 048 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de York D1EE 048 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met York D1EE 048 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.