036-21366-007-A-12 05 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TECHNICAL GUIDE AFFINITY™ SERIES SINGLE P ACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TO.
036-21366-007-A-12 05 2 Unitary Products Group T ABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STANDARD FEATURES/BENEFITS . . . . . . . . . . . . 3 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . 4 TYPICAL WIRING DI AGRAM NOTES .
036-21366-007-A-1205 Unitary Products Group 3 ST ANDARD FEA TURES/BENEFITS OPERATING EFFICIENCY - All units provide high operating efficiencies and have a mi nimum AFUE of 80% and SEER of 13.0. All efficiencies exceed legislated minimum levels. ON SITE FLEXIBILITY - All model sizes share a common, compact design cabinet in a sin gle footprint.
036-21366-007-A-12 05 4 Unitary Products Group FAN SYSTEM - All 2-1/2, 3, 3- 1/2 and 4 ton models operate over a wide range of design conditio ns with a consta nt CFM, electrically commutated (ECM) fa n motor. These units easily match all types of applications and pro vi de grea ter on site flexibility to match comfort requirement.
036-21366-007-A-1205 Unitary Products Group 5 enthalpy to determine the most econ omical mix. Single Enthalpy sensor also requ ired. PRESSURE SWITCH UPGRADE KIT - Con ta ins scre w in type High pressure, Low Pressure/Loss of Ch arge switch, freeze protection switch and lockout relay.
036-21366-007-A-12 05 6 Unitary Products Group FIGURE 2 - UNIT COMPONENT LOCA TION DIRECT DRIVE CONDENSER FAN MOTOR HIGHLY EFFICIENT E N HANCE COPPER TUBE/ALUMINUM FIN EVAPORATOR COIL HIGHLY EFFICIENT.
036-21366-007-A-1205 Unitary Products Group 7 T ABLE 2: R A TI NGS COOLING/GAS HEA TING MODEL DNP NET COOLING CAP ACITY 1 SOUND RA TING (dbels) 2 GAS HEA T CAP ACITY / EFFICIENCIES MBH SEER 3 EER 4 INPUT (MBH) OUTPUT (MBH) AFUE 5 (%) NUMBER OF BURNERS TEMP .
036-21366-007-A-12 05 8 Unitary Products Group T ABLE 3: DNP024 COOLING CAPACITIES - 2 TON AIR ON EV APORA TOR COIL TEMPERA TURE OF AIR ON CONDENSER COIL TEMPERA TURE OF AIR ON CONDENSER COIL 85°F 95°F NET CAP . MBH POWER INPUT KW SENSIBLE CAP ACITY 1 NET CAP .
036-21366-007-A-1205 Unitary Products Group 9 T ABLE 3: D NP024 COOLING CAP ACITIES - 2 TON (CON T’D) AIR ON EV APORA TOR COIL TEMPERA TURE OF AIR ON CONDENSER COIL 125°F NET CAP . MBH POWER INPUT KW SENSIBLE CAP ACITY 1 ENTERING DRY BULB, °F CFM WB °F 86 83 80 77 74 71 68 600 72 18.
036-21366-007-A-12 05 10 Unitary Products Group T ABL E 4: DNP030 COO LING CAP ACITIES - 2-1/2 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 1,000 CFM 1,250 CFM WB °F WB °F 72 67 62 57 72 67 62 57 85 °F NET CA P .MBH 33.6 31.6 30.
036-21366-007-A-1205 Unitary Products Group 11 T ABLE 5: DNP036 COOLING CAP ACITIES - 3 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 1,200 CFM 1,350 CFM WB °F WB °F 72 67 62 57 72 67 62 57 85 °F NET CAP . MBH 43.3 39.9 37.4 3 6.
036-21366-007-A-12 05 12 Unitary Products Group T ABL E 6: DNP042 COO LING CAP ACITIES - 3-1/2 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 1,350 CFM 1,500 CFM WB °F WB °F 72 67 62 57 72 67 62 57 85 °F NET CA P . 48.4 44.5 40.
036-21366-007-A-1205 Unitary Products Group 13 T ABLE 7: DNP048 COOLING CAP ACITIES - 4 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 1,400 CFM 1,600 CFM WB °F WB °F 72 67 62 57 72 6 7 62 57 85 °F NET CAP . MBH 54.0 49.2 45.6 45 .
036-21366-007-A-12 05 14 Unitary Products Group T ABLE 8: DNP060 COOLING CAP ACITIES - 5 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 1,500 CFM 1,800 CFM WB °F WB °F 72 67 62 57 72 67 62 57 85 °F NET CAP . MBH 63.5 57.6 52.7 53 .
036-21366-007-A-1205 Unitary Products Group 15 T ABLE 9: TWO TON AIR PERFORMANCE 1 MODEL # DNP (Cooling/ Heating) MTR SPD EXTERNAL ST AIC PRESSURE - IWG .
036-21366-007-A-12 05 16 Unitary Products Group T ABLE 10: SID E SUPPL Y AIR BLOW ER PERFORMANCE - 208/230 VOL TS 1 MODEL # DNP MODE (COOLING / HE A TING) CFM EXTERNAL ST A TIC PRESSURE - IWG .
036-21366-007-A-1205 Unitary Products Group 17 T ABLE 1 1: BOTTOM SUPPL Y AIR BLOWER PERFORMANCE - 208/230 V OL TS 1 MODEL # DNP MODE (COOLING / HEA T ING ) CFM EXTERNAL ST A TIC PRESSURE - IWG .
036-21366-007-A-12 05 18 Unitary Products Group FIGURE 3 - FIELD WIRING DIAGRAM CONTROL WIRIN G T ABLE 12: AD DITIONAL ST A TIC PRESSURE RESIST ANCE - 2, 2-1/2, 3 TON DESCRIPTION RESIST ANCE, IWG CFM 500 600 700 800 900 1,000 1,100 1,200 1 , 300 1,400 1,500 1,600 WET EV APORA TOR COIL .
036-21366-007-A-1205 Unitary Products Group 19 FIGURE 4 - POWER WIRING FIELD DIAGR AM G R O U N D L U G R E F E R T O E L E C T R I C A L D A T A T A B L E S T O S I Z E T H E D I S C O N N E C T F I .
036-21366-007-A-12 05 20 Unitary Products Group FIGURE 5 - UNIT DIMENSIONS - FRONT All dimensions are in inches. They are subject to change with- out notice.
036-21366-007-A-1205 Unitary Products Group 21 FIGURE 6 - UNIT DIMENSIONS - FRONT & B OTTOM FIGURE 7 - UNIT DIMENSIONS - BACK & BOTTOM 1 - 3 / 4 1 5 2 9 - 9 / 1 6 1 5 3 - 1 / 2 1 - 3 / 4 1 - 3.
036-21366-007-A-12 05 22 Unitary Products Group FIGURE 8 - TYPICAL SLAB ON GRO UND INST ALLA TION FIGURE 9 - TYPICAL ROOF CURB INST ALLA TION F I E L D S U P P L I E D D I S C O N N E C T S W I T C H .
036-21366-007-A-1205 Unitary Products Group 23 FIGURE 10 - TYPICAL DUCT APPLI CA TION S FIGURE 1 1 - UNIT CEN TER OF GRA VITY R O O F C U R B I N S T A L L A T I O N R E A R D U C T R O O F C U R B I .
036-21366-007-A-12 05 24 Unitary Products Group FIGURE 12 - ROOF CURB DIMEN SIONS 1 FIGURE 13 - ROOF CURB CR OSS SECTION 1. 8” Roof curb also available O P E N I N G F O R R E T U R N A I R D U C T .
036-21366-007-A-1205 Unitary Products Group 25 FIGURE 14 - TYPICAL WIRING DIAGRAM D*NP 024 (208/230-1-60 POWER SUPPL Y).
036-21366-007-A-12 05 26 Unitary Products Group FIGURE 15 - TYPICAL WIRING DIAGRAM D* NP 030-048 (208/230 -1-60 POWER SUPPL Y) 7 DETAIL "A" T2 L2 M1-2 COOL/BLU HEAT/BK R/RED 224/R 240V/BLK 2.
036-21366-007-A-1205 Unitary Products Group 27 FIGURE 16 - TYPICAL WIRING DIAGRAM D*NP 060 (208/230-1-60 POWER SUPPL Y).
036-21366-007-A-12 05 28 Unitary Products Group FIGURE 17 - TYPICAL WIRING DIAGRAM D* NP 030-048 (208/230 -3-60 POWER SUPPL Y) 17H 15H 3H,5H 10G 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 G/GR.
036-21366-007-A-1205 Unitary Products Group 29 FIGURE 18 - TYPICAL WIRING DIAGRAM D*NP 060 (208/230-3-60 POWER SUPPLY).
036-21366-007-A-12 05 30 Unitary Products Group FIGURE 19 - TYPICAL WIRING DIAGRAM D* NP 030-048 (460/575 -3-60 POWER SUPPL Y).
036-21366-007-A-1205 Unitary Products Group 31 FIGURE 20 - TYPICAL WIRING DIAGRAM D*NP 060 (460/575-3-60 POWER SUPPL Y).
036-21366-007-A-12 05 32 Unitary Products Group TYPICAL WIRING DIAGRAM NOTES 1. All field wiring to be accomplished followin g city , local and/or national codes in effect at time of installation of this unit. 2. Caution: Label all wires prior to disconnection when ser- vicing controls.
036-21366-007-A-1205 Unitary Products Group 33 MECHANICAL SPECIFICA TIONS GENERAL Units shall be manufactured by Y ork Intern ational Unitary Products Group in an ISO 9001 certified facility . YORK’s DNP is a unit that gives you the flexibility and choices yo u need in today’s market.
036-21366-007-A-12 05 34 Unitary Products Group UNIT OPERA TING CHARACTERISTICS Unit shall be capable of starting and running at 125º F out- door temperature, exceeding maximum load criteria ARI S tandard 210/240. The compre ssor , with standard controls, shall be capable of operation down to 45º F outdoor temp era- ture.
036-21366-007-A-1205 Unitary Products Group 35.
Subject to change without notice. Printed in U.S. A. 036-21366-007-A-1205 Copyright © 2005 by Unitary Products Group. All right s reserved. Supersedes: 036-21366-006-A-10 05 Unitary 5005 Norman Produ.
Een belangrijk punt na aankoop van elk apparaat York DNP024 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen York DNP024 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens York DNP024 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding York DNP024 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over York DNP024 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van York DNP024 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de York DNP024 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met York DNP024 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.