036-21031 -004 Rev. A (0603) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE ® TECHNIC AL GUIDE STELLAR PLUS TM 12 SEER SPLIT -SYSTEM HEA T P UMPS MOD ELS: E*FH018 Thru E*FH06 0 (1.5 THRU 5 NOMINAL TONS) Due to cont inuous produc t improvem ent, specifi cations are subje ct to change w ithout notice.
036-2103 1-004 Re v. A (0603 ) 2 Unitary Produ cts Grou p All dim ensions are in inches. They are subje ct to ch ange withou t notice. Certif ied dimens ions will be provide d upon request. PHYSICAL AND ELECTRICAL DA T A MODEL E4FH018 E4FH024 E4FH030 E4F H036 E4FH045 E5FH048 E4FH060 Unit Supply V olt age 208/230-1-60 Normal V olt age Range 1 1.
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 3 PROCEDURES: 1. Unit factory charge list ed on the unit nameplate includes refigerant for the condenser , the smallest evaporator and for 15 f eet of intercon- necting line tubing.
036-2103 1-004 Re v. A (0603 ) 4 Unitary Produ cts Grou p - = No t appl icab le COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 1. G2 FD co ils av ailab le wi th a f acto ry in sta lle d hori zont al drain pan. See p rice pag es for spec ific m ode l number .
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 5 * Require s a 2F D Blower T ime De lay unl ess a standa rd furn ace is e quipped with one . ** Refer to Qu ick Selection Chart for specific fu rnace m atch-u p.
036-2103 1-004 Re v. A (0603 ) 6 Unitary Produ cts Grou p HEA TING PERFORMANCE - Air Handler and Mu lti-position Coils UNIT MODE L COIL 1 MODE L ARI HEA TING 2 OUTD O O R TE M P 3 47 ° F 17 ° FH S P F- 3 ° F 7 ° F1 7 ° F 27 ° F 37 ° F 47 ° F5 7 ° F MBH COP MBH COP STD.
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 7 COP equa ls MBH output divided b y (total KW inp ut x 3.4 12). HSPF ( Heating Seasonal Perfo rmanc e Factor) is the to tal heati ng outpu t duri ng a nor mal ann ual usa ge per iod for heating divided by t he total ele ctric power input du ring th e same period .
036-2103 1-004 Re v. A (0603 ) 8 Unitary Produ cts Grou p ACCESSORIES Refer to Price Ma nual for sp ecific mod el numbe rs. St art Ass ist Kit (2SA067*) Blow er Ti me Del ay - Avail able to in crease ef fic iency whe n inst alled.
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 9 TYPICAL INST ALLA TION TYPICAL FIELD WIRING - (AIR HANDLER / ELECTRICAL HEA T ) THERMOST A T TO INDOOR BLOWER TO COIL NEC CLASS 2 WIRING NEC CLAS.
036-2103 1-004 Re v. A (0603 ) 10 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d.
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 11 Multipliers for determining the performance with oth er indoor sections. NOTE: For dry b ulb tem peratu res differe nt than tho se list ed (be t.
036-2103 1-004 Re v. A (0603 ) 12 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d.
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 13 Multipliers for determining the performance with oth er indoor sections. NOTE: For dry b ulb tem peratu res differe nt than tho se list ed (be t.
036-2103 1-004 Re v. A (0603 ) 14 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d.
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 15 Multipliers for determining the performance with oth er indoor sections. NOTE: For dry b ulb tem peratu res differe nt than tho se list ed (be t.
036-2103 1-004 Re v. A (0603 ) 16 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d.
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 17 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO. E4FH018S06 EV APORA TOR COIL MODEL NO. F 2RP/F2FP024 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
036-2103 1-004 Re v. A (0603 ) 18 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO. E4FH024S06 EV APORA TOR COIL MODEL NO. F 2RP/F2FP030 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 19 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E4FH30S06 EV APORA TOR COIL MODEL NO G2FD030(S,H)17 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
036-2103 1-004 Re v. A (0603 ) 20 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO. E4FH036S06 EV APORA TOR COIL MODEL NO. F 2RP/F2FP036 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 21 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E4FH042S06 EV APORA TOR COIL MODEL NO F2RP/F2FP042 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
036-2103 1-004 Re v. A (0603 ) 22 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E5FH048S06 EV APORA TOR COIL MODEL NO F2FP048 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 23 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E4FH060S06 EV APORA TOR COIL MODEL NO G2FD060(S,H)24 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
Subject to change without notice. Printed in U.S.A. 036-21031-004 Rev. A (0603) Copyright © by Y ork International Corp. 2003. All rights reserved. Supersedes: 036-21031-003 Rev .
Een belangrijk punt na aankoop van elk apparaat York E*FH018 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen York E*FH018 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens York E*FH018 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding York E*FH018 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over York E*FH018 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van York E*FH018 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de York E*FH018 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met York E*FH018 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.