Gebruiksaanwijzing /service van het product YHJD18 THRU 60 van de fabrikant York
Ga naar pagina of 30
TECHNICAL GUIDE SPLIT -SYSTEM HEA T PUMPS 13 SEER – R-22 MODELS: Y HJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) Due to continuous produc t impr ovement, specifications are subject to change without notice. V isit us on th e web at www .york.com A dditional rating informa tion can be fo und at w ww .
398612-YTG-B-0608 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to cha nge without notice. Ce rtif ied dimensio ns will be provide d upon request.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 3 Additional R-22 Charge / Orifice Size for V arious Matched Systems Outdoor Unit YHJD18 S21S1 YHJD24 S21S1 YHJD30 S21S1 YHJD36 S21S1 YHJD42 S21S1 .
398612-YTG-B-0608 4 Johnson Controls Unitary Products PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refr igerant for th e condenser , the smallest evaporator and 15 feet of inter- connecting line tubing.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 5 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT A L SENS. 13 SEER HP WITH MA YHJD18S21S1 MA08B 17 FC/MC18B 600 18.0 12.
398612-YTG-B-0608 6 Johnson Controls Unitary Products — = Not applicable. 13 SEER HP WITH A V / SV / F*FV - V ARIABLE SPEED YHJD18S21S1 A V24 17 – 565 18.0 13.4 14.00 12.00 YHJD24S21S1 A V24 17 – 770 23.0 17.5 14.00 12.00 YHJD30S21S1 A V36 21 – 1015 29.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EER TOT A L SENS. YHJD18S21S1 450 - 750 14,17 FC/MC/PC/UC18 600 18.
398612-YTG-B-0608 8 Johnson Controls Unitary Products COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT A L SENS. 13 SEER HP WITH V ARIABLE SPEED FURNACES 2 YHJD18S21S1 PV8*A12 FC/MC/PC/UC18A 14 600 18.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 9 YHJD36S21S1 PV8*A12 FC/MC/PC/UC37A 14 1200 35.0 26.0 13 .55 1 1.00 PV9*A12 FC/MC/PC/UC37A 14 1200 35.0 25.8 13 .25 1 1.00 PV8*B16 FC/MC/PC/UC43B 17 1200 35.0 26.2 14 .00 12.00 PV8*C16 FC/MC/PC/UC43C 21 1200 35.
398612-YTG-B-0608 10 Johnson Controls Unitary Products HEA TING PERFORMANCE - With Air Handler UNIT MODEL* AIR HANDLER COIL 1 MODEL ARI HEA TING 2 47 ° F1 7 ° FH S P F MBH COP KW MBH COP KW STD 13 SEER HP WITH MA YHJD18S21S1 MA08B FC/MC18B 17.0 3.26 1.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 11 CP equals MBH output divided by (t otal KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating ou tput during a normal annual usage period for heating divided by the total electric power input during the same period.
398612-YTG-B-0608 12 Johnson Controls Unitary Products CP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heat ing output during a normal annual usage period for heating divided by the total electric power input during the same period.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 13 HEA TING CAP ACITY - Wit h V ariable S peed Furnac es UNIT MODEL V ARIABLE SPEED FURNACE COIL 1 MODEL ARI HEA TING 2 47 ° F1 7 ° FH S P F MBH COP KW MBH COP KW STD 13 SEER HP WITH V ARIABLE SPEED FURNACES 3 YHJD18S21S1 PV8*A12 FC/MC/PC/UC18A 17.
398612-YTG-B-0608 14 Johnson Controls Unitary Products CP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heat ing output during a normal annual usage period for heating divided by the total electric power input during the same period.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 15 ACCESSORIES Refer to Price Manual for specific model numbers. St art Assist Kit (2SA067*) Blower Time Delay - A vailable to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute a fter cooling thermostat has been satisfied.
398612-YTG-B-0608 16 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 17 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between.
398612-YTG-B-0608 18 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 19 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between.
398612-YTG-B-0608 20 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 21 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between.
398612-YTG-B-0608 22 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween.
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 23 Multipliers for determining the performance with other indoor sections . HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO YHJD18S21S1 EV APORA TOR COIL MODEL NO AHP18 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
398612-YTG-B-0608 24 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO YHJD24S21S1 EV APORA TOR COIL MODEL NO AHP24 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 25 Multipliers for determining the performance with other indoor sections . HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO YHJD30S21S1 EV APORA TOR COIL MODEL NO AHP30 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
398612-YTG-B-0608 26 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO YHJD36S21S1 EV APORA TOR COIL MODEL NO AHP36 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 27 Multipliers for determining the performance with other indoor sections . HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO YHJD42S21S1 EV APORA TOR COIL MODEL NO FC/MC/PC/UC48 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
398612-YTG-B-0608 28 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO YHJD48S21S1 EV APORA TOR COIL MODEL NO AHP/SHP48 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
398612-YTG-B-0608 Johnson Controls Unitary Produ cts 29 Multipliers for determining the performance with other indoor sections . HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO YHJD60S21S1 EV APORA TOR COIL MODEL NO FC/MC62 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP .
Subject to change without notice. Printe d in U.S.A. 398612-YTG-B-0608 Copyright © 2008 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 398612-YTG-A-0408 Johnson Controls Unitary Product .
Een belangrijk punt na aankoop van elk apparaat York YHJD18 THRU 60 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen York YHJD18 THRU 60 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens York YHJD18 THRU 60 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding York YHJD18 THRU 60 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over York YHJD18 THRU 60 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van York YHJD18 THRU 60 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de York YHJD18 THRU 60 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met York YHJD18 THRU 60 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.