C OOKER HOOD ZHC 950 INSTRUCTION BOOKLET.
.
Customer Care Department Zanussi 55 - 77 High S treet Slough Berkshire SL1 1DZ T el: 08705 727 727 T o register ownership, please ensure you complete and return the guarantee card supplied with the appliance.
These warnings are provided in the interests of safety . Ensure that you underst an d them all before installing or using this appliance. Y our safety is of paramount impor- tance. If you are unsure about any of the meanings of these warnings contact the Customer Care Department.
3 YOUR APPLIANCE OPERA TING INSTRUCTIONS This cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. Cooker Hood Controls The cooker hood functions are controlled by four push button switches located centrally in the control fascia.
T o Operate Select the required fan speed and light if required. The appliance can be installed to recirculate or extract contaminated air . The cooker hood is more effective when used in the extraction mode. Recirculation The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter fitted.
Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply . The cooker hood must be kept clean, as a build up of grease or fat can be a fire hazard. External Cleaning Wipe the cooker hood frequently with warm soapy water using a mild detergent.
Position the new charcoal filter in the position marked and while holding the filter replace the fixing hooks as illustrated. This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended. Changing the Light Bulb Remove the screw fixing the lighting support.
If, having followed these instructions carefully , your cooker hood fails to work properly please carry out the following checks. SOMETHING NOT WORKING Symptom The cooker hood will not start The cooker hood is not working effectively • Check the hood is connected to the electricity supply .
8 GUARANTEE CONDITIONS We, Zanussi, undertake that if within twenty four months of the date of the purchase this Electrolux built-in product or any part thereof is proved to be defective by reason onl.
INST ALLA TION INSTRUCTIONS It is dangerous to alter the specifications or attempt to modify this product in any way . T echnical information DIMENSIONS HEIGHT OF CANOPY : (incl glass visor) 52mm HEIG.
INST ALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the event of a breakdown. All installations must comply with the local authorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this cooker hood.
11 Clearance Heights The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated, providing the maximum output of the appliance beneath does not exceed the maximums quoted in the T echnical Specifications.
Fix the lower bracket item 7.2.1 using two 4.2x44.4 wall fixing screws item 12a . Fix the upper fixing bracket item 7.2.1 and the recirulation outlet support item 7.3 together using two 4.2x44.4mm wall fixing screws item 12a as illustrated. Insert two 4.
Fitting the Hood Body Before starting to fix the hood body , tighten the two screws Vr located on the top of the hood body . Hook the hood body onto the two 4.2x44.4mm screws item 12a . Fully tighten the screws item 12a . Using a screw driver and spirit level, adjust the screws item V r until the hood body is level.
Extraction The charcoal filter is not required in this mode and should be removed. Ducting The ducting used must be Ø150mm (6ins), or Ø125mm (5ins) in diameter . If possible duct through the wall immediately above the hood body . For the best performance use the shortest possible duct run and the minimum number of bends.
15 Fitting the Chimney Stack The chimney consists of two sections. The lower chimney measures 740mm and the upper chimney (with the recirculation grilles on either side) measures 465mm. The overall installed measurement is min. 870 - max 1200mm. UPPER CHIMNEY T o fit the upper chimney section item 2.
.
.
43600 1681 0 1 - 0 30210 © Electrolux plc 2002.
Een belangrijk punt na aankoop van elk apparaat Zanussi ZHC 950 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Zanussi ZHC 950 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Zanussi ZHC 950 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Zanussi ZHC 950 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Zanussi ZHC 950 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Zanussi ZHC 950 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Zanussi ZHC 950 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Zanussi ZHC 950 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.