Z-Plex 10 User ’s G uide Model Number: Z-PLEX-10-24-DOC-SC June 2000 Zhone Technolog ies.
Model No. Running Head Trade mark s: SECHTOR 300 and Z-Plex are registered trademar ks of Zhone Tech nologies Zhone and th e Zhone logo are regis tered trademarks of Zhone Technolog ies All other trademarks and registered trademar ks are the property of their respective holders.
REGULATORY INFORMATION Federa l Comm un ic at i on s Comm is s io n (F CC) Part 15 Regula tion For T elephon e Equipme nt The produc t described herein h as been test ed and found to comply wi th the limi ts fo r a Class “A” D igita l Devi ce, pursu ant to Part 15 of th e FCC R ules.
Model No. Running Head If this equipment (Z-Plex 10) cause s harm to the t elephone n etwork, the telephone compa ny will not ify you in advance th at tempora ry discontin uance of s ervice may b e require d. But if advance no tice isn ’ t p ractical, t he tele phone company will notify th e customer as soon as possibl e.
Repairs t o certifi ed equipment sh ould be made b y an author ized Canadi an maintenance facili ty design ated by th e supplier . Any repairs or alter ations made by the user t o this equipme nt, or equi pment malfunct ions, may giv e the tel ecommunicati ons company c ause to request the user to disconn ect the eq uipment.
Model No. Running Head.
Zhone Technol ogies / vii Contents Contents Chapter 1 Introdu ction 1.1 Product overv iew ..................... ........................... .................. .......................... 1-1 1.2 Features ........ ........................... ...........
viii Zhone Technologies Model No. Running Head Contents 3.4 Alarm ................ ........................... ........................... ........................... ............ 3-5 3.5 Grounding requi rements ....................... ..............
Zhone Techno logies / ix Contents Appendi x A Alphab etical Refer ence A.1 Parameter re ference ................................... ........................... ......................... A-1 A.1.1 Configurat ion groups .................... ............
x Zhone Technologies Model No. Running Head Contents.
Zhone Technologi es / 1-1 Introduction Product overvi ew Chapter 1 Introduction This chapt er intr oduces you t o the featur es and bene fits of the inte grated acces s soluti on that pe rmits voice and data inte gration in a single u nit.
1-2 Zhone Technologies Model No. Running Head Features Introducti on 1.2 Featur es • V oice and data ch annel bank wi th integ ral CSU/DSX interfa ce • Sleek, l ow profile, one rack unit (1 RU) chassi s • From 12 to 1 6 FXS analog vo ice ports • Up to 8 FXO por ts • One high sp eed V .
Zhone Technologi es / 1-3 Introduction Managing the Z-Plex When a T1 p ort is co nfigured for TR-08 format , the voic e channels assigned to this port are identif ied by channel number (ac cording to t he TR-TSY -000008 doc ument), whic h may be dif ferent fr om the T1 time slot number .
1-4 Zhone Technologies Model No. Running Head Product spe cifications Introduction • T1 config uration, performance st atisti cs, alarm c onditions, an d diagnost ics. • FXS/FXO confi guration, status, and d iagnostics. • Data port configur ation, st atus, and diagnostics .
Zhone Technologi es / 1-5 Introduction Product specifications T1 int erface Physical Fram e f ormat Line c ode Line e qualizat ion CSU li ne bu ild O ut ( L BO) DSX line length Cloc king FDL Input leve l TR08 supp ort Diagno stics T wo RJ48 D4, ESF , SLC9 6 (TR -08) AMI, B8ZS 0 to 133 ft.
1-6 Zhone Technologies Model No. Running Head Product spe cifications Introduction.
Zhone Technologi es / 2-1 Installing the Z-Plex Product descr iption Chapter 2 Installing the Z-Plex This chapt er gives you quick, simple i nstruction s to get yo u up and runn ing.
2-2 Zhone Technologies Model No. Running Head Unpacking the produ ct Install ing the Z-Plex 2.1.2 Fr ont panel The Z-Plex front pan el provid es LEDs for moni toring the status of the unit . 2.2 Un pac ki ng the pr oduct This prod uct is shipped as a complete pac kage that incl udes this user ’ s guide.
Zhone Technologi es / 2-3 Installing the Z-Plex Installing the product 2.2.4 Hard ware, cabli ng, and opti onal access ories The product comes packa ged with an AC power cord to p rovide power to the unit . It is also shipped wi th two angl e brackets a nd screws f or rack mounti ng.
2-4 Zhone Technologies Model No. Running Head Installing the product Instal ling the Z-Plex 1. Never ins tall te lephone wir ing during a lightnin g storm. 2. N ever i nst al l thi s prod uct in a wet locat ion . 3. Never inst all telep hone jacks in wet lo cat io ns unl ess the jack is speci ficall y desi gned for this pur pose only .
Zhone Technologi es / 2-5 Installing the Z-Plex Rack mounting 2.4 Rack mounting The product chassis comes with b rackets for rack mounting; and the ch assis is designed to accommodate brackets for front ce nter or r ear mounting. T he instal lation sit e for rac k mounting sh ould provide p roper roo m for venti lation and ca ble routing .
2-6 Zhone Technologies Model No. Running Head Locating the product on a desktop Install ing the Z-Plex 2.5 Locating the pr oduct on a desktop Each unit can be eas ily set o n top of a d esk or table. A stable e nvironment i s necess ary for peak perf ormance of each unit.
Zhone Technologi es / 3-1 Electric al Installati on Connector type Chapter 3 Electrical Installation When you ar e rea dy to go be yond t he basi cs of th e pro duct, u se this chapte r to lear n sp ecifics on groundi ng, cablin g, and the ne cessary p ower requireme nts for op eration.
3-2 Zhone Technologies Model No. Running Head Data port connector pinouts Electrical Ins tallation 3.2 Data port connector pi nou ts T able 3-2 descr ibes the signals and p ins for t he V .35 data port . The pin assi gnments are associa ted with the u se of Zhone c able part nu mber PRM-000-012 61M (F).
Zhone Technologi es / 3-3 Electric al Installati on Data port connect or pinouts Note: For pur poses of conne ction and f unction, the pr oduct should b e consider ed a DCE. 3.2.1 FXO/F XS conn ectors T able 3-3 lis ts the FXS/FXO conn ector pin outs.
3-4 Zhone Technologies Model No. Running Head Power requirements Electrical Ins tallation 3.2.2 RJ48 connec tor T able 3-4 lists the T1 RJ48 co nnector pinou ts. 3.3 Power requir ements The inst allation sit e should ha ve a 90-26 0V AC power r eceptacl e readily a vailable to powe r up the unit .
Zhone Technologi es / 3-5 Electric al Installati on Alarm 3.3.1 Power instal lati on 3.3.1.1 AC power installation This prod uct is equ ipped with an AC r eceptacl e located on t he back of th e unit.
3-6 Zhone Technologies Model No. Running Head Groundi ng requirements Electrical I nstallation Note: Note that the Exte rnal Alarm Plug i s black in co lor , matching the r ecipr ocal blac k r ear panel r eceptacle . Figure 3-2. Alarm closure plug 3.
Zhone Technologi es / 3-7 Electric al Installati on Cabling Figur e 3-3. Groundin g the unit 3.6 Cabling T able 3-5 describ es the cab les reco mmended for use with the Z-Plex unit .
3-8 Zhone Technologies Model No. Running Head Cabling Electrical I nstallation.
Zhone Technologi es / 4-1 Configuring the Z-Plex Using the command line interfac e Chapter 4 Configuring the Z-Plex In this chapter y ou will le arn how to confi gure the Z-Plex uni t using th e CLI.
4-2 Zhone Technologies Model No. Running Head Quick start sys tem co nfiguration Configuring the Z-P lex SET T1CFG:STATE:1:ACTV T o read the cu rrent frame sli ps on the first T1 li n e, en ter the follo wing comm and: GET PMCUR:SLIP:1 Keep in mind the fo llowing i mportant i nformation : • The CLI is case sensit ive .
Zhone Technologi es / 4-3 Configuring the Z-Plex Quick star t system configuratio n 3. Change the default user password. For example: user> SET USER:PASSWD:zplex321 The passwor d can be from 7 to 12 charac ters long. The password is used any time you lo g into t he Z-P lex u nit t o mana ge it .
4-4 Zhone Technologies Model No. Running Head Quick start sys tem co nfiguration Configuring the Z-P lex The fir st time you configure an IP address , you must reboot the syst em. 4.2. 1 L ogging in and out o f the syst em Y ou must log in to the syste m to manage it .
Zhone Technologi es / 4-5 Configuring the Z-Plex Quick star t system configuratio n Configuring the loc al management channel The Z-Plex unit pr ovides an out-of -band RS232 seria l (craft) inte rface for ma naging the unit .
4-6 Zhone Technologies Model No. Running Head Configuring SNMP Configuring the Z-Plex The foll owing example configures t he IP over FDL interf ace: user> SET CPUCFG:MASKFDL:1:255.255.255.252 user> SET CPUCFG:IPFDL:1:192.168.8.22 For most ap plications, the defau lt MTU of 1500 i s appropr iate.
Zhone Technologi es / 4-7 Configuring the Z-Plex Configuring T1 interfaces user> SET CPUCFG:IPHOST2:1:192.168.21.24 user> SET CPUCFG:IPHOST3:1:192.
4-8 Zhone Technologies Model No. Running Head Configuring a T 1 drop and insert interfa ce Configuring the Z-Plex user> SET T1CFG:DS0:1:OFF 4.5 Configuring a T1 dr op and insert interface A T1 drop and insert take s some channe ls from an inc oming T1 int erface and dr ops some of them out to a PBX and th e rest to an outgoing dat a path.
Zhone Technologi es / 4-9 Configuring the Z-Plex Configuring FXO ports user> SET FXSCFG:TYPE:1:LSFD 6. Specify whether tr unk condit ioning is being used : user> SET FXSCFG:TRNKC:1:ON 7. Specify whether you want the Z- Plex unit to p rovide ri ngback.
4-10 Zhone Technologies Model No. Running Head Configuring the V.35 data port Configuring the Z-Plex user> SET FX0CFG:TS:2:7-15 5. Specify the FXO type: user> SET FX0CFG:TYPE:2:LS 6. Specify whether you want the Z- Plex unit to p rovide ri ngback.
Zhone Technologies / 4-11 Configuring the Z-Plex Adding and deleti ng routes 3. Specify the T1 int erface the d ata is com ing in on: user> SET DPCFG:WAN:1:2 4. Specify the number of channels : user> SET DPCFG:NCHAN:1:24 5. Specify the star t channel : user> SET DPCFG:SCHAN:1:1 6.
4-12 Zhone Technologies Model No. Running Head Adding and del eting routes Configuring the Z-Plex user> SET ROUTE:DLTNETRT: x:destination:gateway For example , the foll owing command de letes a network rou te (rout e number 2) f rom the 192.168. 0.
Zhone Technologies / 4-13 Configuring the Z-Plex Adding and deleti ng routes Figur e 4-1. Example routing configuration In the ex ample networ k in Figure 4- 1, the Z-Plex u nit A has two IP interfaces : a DS0 management i nterfac e with an addr ess of 128.
4-14 Zhone Technologies Model No. Running Head Adding and del eting routes Configuring the Z-Plex T able 4-1expla ins the i nterfac es in the route table . T able 4-1. Route Display V alues 4.9.4.1 Displaying host r outes T o display inf ormation about all host r outes, enter the ROUTE:HOST ALL:x command.
Zhone Technologies / 4-15 Configuring the Z-Plex System maintenance commands user> GET ROUTE:HOST:1 >The Host Destination is: 192.168.21.32 >The Host Gateway is: 12.12.1.1 4.9.4.2 Displaying network r outes T o dis play inform ation about all host route s, enter the ROUTE:NET ALL:x command.
4-16 Zhone Technologies Model No. Running Head System maintenance commands Configuring the Z-Plex BANK2 ->Software version : ZPLEX10_1.0.0#6 ->Checksum : 0x50a78d4c Active bank is 1 4.
Zhone Technologies / 4-17 Configuring the Z-Plex System maintenance commands 4.10 .6 Acti vatin g code in ban k 1 T o activate t he code in bank 1, enter t he following c ommand: user> ACTIVEBANK1 4.10 .7 Acti vatin g code in ban k 2 T o activate t he code in bank 2, enter t he following c ommand: user> ACTIVEBANK2 4.
4-18 Zhone Technologies Model No. Running Head System maintenance commands Configuring the Z-Plex.
Zhone Technologi es / 5-1 Diagnostics T1 loopbacks Chapter 5 Diagnostics This chapt er describ es how to per form loopbacks on the Z-Pl ex unit inte rfaces.
5-2 Zhone Technologies Model No. Running Head T1 loopbacks Diagnostics Figur e 5-1. T1 loopbacks T o activate a loopback, e nter the following command: user> SET T1CFG:LOOPBACK: x :(LINEON/LOCALON) where x is the nu mber of the T1 inter face to loopb ack.
Zhone Technologi es / 5-3 Diagnostics BER testing 5.2 BER testing The bit error rate (BER) test sends a data pat tern an d measures the bit error ra te on the selected interf ace. The Z-Plex supports BER t ests on enti re T1 lines or on indiv idual ti me slots.
5-4 Zhone Technologies Model No. Running Head Data port loopbacks Diagnostics user> SET T1CFG:TSBERTOFF: x :(1-24) 5.3 Data port loopbacks The V .35 port sup ports li ne and loca l loopback s: •.
Zhone Technologi es / 5-5 Diagnostics Testing FXO and FXS ports Figure 5-2. Data port loopbacks T o activate a data port lo opback, use t he following command: user> SET DPCFG:LOOPBACK:1:(LINE/LOCAL) T o de-activat e a data p ort loopback, u se the fo llowing comman d: user> SET DPCFG:LOOPBACK:1:OFF 5.
5-6 Zhone Technologies Model No. Running Head Testing FXO and FXS ports Diagnos tics • Loopbacks • Settin g and viewin g the tran smit and re ceive ABCD sig naling bi ts • Settin g the tip a nd ring l eads • Read ing th e tip a nd r ing st atis ti cs 5.
Zhone Technologi es / 5-7 Diagnostics Testing FXO and FXS ports Figur e 5-3. FXO and FXS loopbacks 5.4.1.1 Configuring FXO loopbacks T o activate a n FXO port loopbac k, use the fol lowing command: user> SET FXOCFG:LOOP:1:(DGTL/ANLG) where x i s the number of the port t o loopback .
5-8 Zhone Technologies Model No. Running Head Testing FXO and FXS ports Diagnos tics user> SET FXSCFG:LOOP:1:OFF 5.4.2 Using test mo de on t he FXO a nd F XS port s FXO and FXS port s can be se t .
Zhone Technologi es / 5-9 Diagnos tics LED indicators 5.4.2.2 V iew ing the receive ABCD signalin g bits The RxAB (rec eive ABCD) set ting is a re ad-only para meter that displays th e ABCD pattern for tes ting the receive side of the ci rcuit.
5-10 Zhone Technologies Model No. Running Head LED indicators Diagnostics 5.5.2 Ethern et LED A single g reen LED indica tes the op erationa l status of the Ether net port. If the LED is blinkin g, the Ether net port is connected and trans mitting t raffi c.
Zhone Technologies / A- 1 Alphabetical Refe rence Parameter ref erence Appendix A Alphabetical Reference This chapt er pr ovid es a refe renc e to the Z-Ple x CLI param eters , com mand s, and synta x.
A-2 Zhone Tech nologies Model No. Running Head Parameter reference Alphabeti cal Reference DPCFG 1 Da ta port c onfigurati on, such as activ ati on and clo cki ng. LOOP MODE RNGBK R TLP RxAB ST A TE TEST TRCNTRL TRNKC TRST A T TS TTLP TxAB TYPE W AN F ARPMC UR 1 Curren t far en d stat isti cs for the T1 interf aces.
Zhone Technologies / A- 3 Alphabetical Refe rence Parameter ref erence FXOT S T A s in gle va l ue between 1 and 24, or a ra nge of values. T est mode for FXO port s. RXAB TEST TRCNTRL TRST A T TXAB FXSCFG A single value between 1 and 24, or a ra nge of values.
A-4 Zhone Tech nologies Model No. Running Head Parameter reference Alphabeti cal Reference A.1.2 Alphabetic refer ence This sect ion conta ins an al phabetic reference t o all CLI pa ramete rs. PMTOT A single value between 1 and 24, or a ra nge of values.
Zhone Technologies / A- 5 Alphabetical Refe rence Parameter ref erence ALLCUR Displays ES, BES, UAS, SES, SLIP , and LOFC erro rs for t he current 15 minute inter val. Configurat ion gr oup: PMCUR Syntax: GET PMCUR:ALLCUR:x ALLFARCUR Displays ES, BES, UAS, SES, SLIP , and LOFC erro rs for t he current 15 minute inter val.
A-6 Zhone Tech nologies Model No. Running Head Parameter reference Alphabeti cal Reference Syntax: GET PMTOT:ALLTOT:x BERT Activate s a bit err or rate tes t (BER T) on a T1 l ine. The BER test sends a da ta pattern a nd mea sures the bi t err or rate on t he sel ec ted time slot.
Zhone Technologies / A- 7 Alphabetical Refe rence Parameter ref erence CLKSRC Clocking s ource for T1 line. Possibl e values a re: • W AN1: Clo ck f or the T1 inter fac e deri ved fr om th e lin e rece iv e si gnal. • W AN2 • INTERNAL: Clocki ng received from internal 1.
A-8 Zhone Tech nologies Model No. Running Head Parameter reference Alphabeti cal Reference Specify a value from 0 t o 100ms in mult iples of 10. Configurat ion gr oup: DPCFG Syntax: (GET/SET) DPCFG:CTSD ELAY:1:(0-100) CUR Curr ent T 1 near-en d st at isti cs.
Zhone Technologies / A- 9 Alphabetical Refe rence Parameter ref erence DSR The Data Set Ready (DSR) o ption allows y ou to define wh ether the V .35 port DSR control lead shou ld be held on (high) or of f (low).
A-10 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference • W AN 2 does not support FDL. Configurat ion gr oup: T1CFG Syntax: (GET/SET) T1CFG:FDL: X:(ANSI/ATT/OFF) FDL_IP Specifi es whether the FDL over IP management interf ace is en abled.
Zhone Techn ologies / A-11 Alphabetical Refe rence Parameter ref erence Notes • If you ar e connecting to Premisy s IMACS on DS0 mgmt chan nel (time slot 24), set HDLC to HDR_OFF . • HDR_ON is compat ible with the Cisco impl ementation of HDLC headers.
A-12 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference LINELEN Specifi es the CSU line build out o r the DSX li ne length. For a CSU, possi ble valu es are: • 00 (0dB ) • N75 ( -7.5dB ) • N15 ( -15.0d B ) • N22 (-22.
Zhone Techn ologies / A-13 Alphabetical Refe rence Parameter ref erence • ANLG: during a digi tal l oop back, t he inco ming digi tal DS0 si gnal i s sent back t o the far end witho ut decodin g it. Configurat ion gr oup: FXOCFG Syntax: (GET/SET) FXOCFG:LOO P:n:(OFF, DGTL, ANLG) LOOP (FXS) Loopback fo r the FXS por t.
A-14 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference MASK Syst em ne twor k mas k. Configurat ion gr oup: CPUCFG Syntax: (GET/SET) CFG:MASK:1 :(net mask) MASKFDL Network mask used fo r IP over FDL traff ic.
Zhone Techn ologies / A-15 Alphabetical Refe rence Parameter ref erence MODE (FXS) FXS supervi sion mode. The Mod e setting sh ould be deter mined by the typ e of equip ment to which you are connecting to the port. All opt ions use two- wire balanced co nnections .
A-16 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference NCHAN Spec ifies the nu mbe r of ti me slo ts o nto whi ch da ta fr om th e T1 li ne wi ll be m appe d. No te tha t starti ng time sl ots must also be select ed for each da ta port.
Zhone Techn ologies / A-17 Alphabetical Refe rence Parameter ref erence RLSD The Receive Level Sign al Detect (RLSD) option al lows you to define whe ther the RLS D cont rol lea d is he ld ON (hig h) or O FF (l o w).
A-18 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference RTLP (FXS) The R TLP setting cont rols the amount of gain or loss ad ded to the incoming si gnal after it is decoded t o analog.
Zhone Techn ologies / A-19 Alphabetical Refe rence Parameter ref erence SCHAN Spec ifies the f ir st T 1 t ime s lot tha t da ta fro m the da ta por t will be ma pped .
A-20 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference STATE (T1 drop and ins ert) S tate of T1 dr op and inse rt ports. Pos sible val ues are: • ACTV • STDBY Configurat ion gr oup: T1CFG Syntax: (GET/SET) T1CFG:STAT E:1:(ACTV/STDBY) ST ATE ( FXO ) S tate of FXO port s.
Zhone Techn ologies / A-21 Alphabetical Refe rence Parameter ref erence SYSCONTACT System cont act info rmation. Enter a strin g of up to 25 cha racters . Note that spa ces are no t allowed. Configurat ion gr oup: SYSTEM Syntax: (GET/SET) SYSTEM:SYS CONTACT:(String) SYSDESCR System descr iption informat ion.
A-22 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference • OFF (defau lt) • ON Configurat ion gr oup: FXOCFG Syntax: (GET/SET) FXOTST:TES T:n:(ON/OFF) TEST (FXS) T est sh ows if the po rt is in the test m ode.
Zhone Techn ologies / A-23 Alphabetical Refe rence Parameter ref erence • LOOP: T ip and Ring le ads are tie d together . • OPE N : Ring lea d is no t con ne cte d to ei th er th e T ip or to g round .
A-24 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference • OFF • ON (defaul t) Configurat ion gr oup: FXSCFG Syntax: (GET/SET) FXSCFG:TRN KC:n:(OFF, ON) TRSTAT (FXO) The T ip and Ring S tatus info rmation field describe s what the a ttached device is doing with the T ip and Ri ng leads of the FXO port.
Zhone Techn ologies / A-25 Alphabetical Refe rence Parameter ref erence Figure 5- 4 illustrat es how to determ ine the TS value if you want to use t he first four t ime slots for drop and inser t ( 0000000f ).
A-26 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference Syntax: (GET/SET) FXSCFG:TS: n:(1-24) See also: W AN (FXS) TSBERTOFF De-a ctiva tes a B ER te st on the s p ecif ie d ch a nne l.
Zhone Techn ologies / A-27 Alphabetical Refe rence Parameter ref erence level, s et the TTLP s etting to a positive val ue (the more po sitive t he number , the more th e signal l evel is decreased). Fo r example, a n incoming sign al at -5 d Bm can be incr eased to - 2 dBm by setti ng the TTLP to - 3 dB.
A-28 Zhone Technologies Model No. Running Head Parameter reference Alphabeti cal Reference • LPFD (Loop start-for ward disco nnect): Prov ides disc onnect when FXS is connec ted to voice mes saging sys tem. • GS (Gr oun d star t): Used with two-way PBX trunks.
Zhone Techn ologies / A-29 Alphabetical Refe rence Parameter ref erence TYPE T ype of T1 i n terf ace. Possi ble va lue s a re: • DSX: Z-Plex presents DSX characteri stics.
A-30 Zhone Technologies Model No. Running Head Command reference Alphabetical Referenc e WAN (FXS) The T1 W AN interfa ce used to provide FXS ser vice. The de fault is W AN 1. Configurat ion gr oup: FXSCFG Syntax: (GET/SET) FXSCFG:WAN :n:(1/2) See also: TS (FXS) A.
Zhone Techn ologies / A-31 Alphabetical Refe rence Error messages QUERYHALARM Displays a list of hi story alar ms. REBOOT Rebo ots th e sy s tem. TFTPDLD This command initiates a TFTP download. It prompts for the IP addres s of the se rver , the code bank to down load the im age to, and the filename o f the softwar e image.
A-32 Zhone Technologies Model No. Running Head Error message s Alphabetical Reference Loopback typ e mismatch User tr ied to deact ivate a l ine loopb ack while l ocal loop back is active.
Zhone Techn ologies / A-33 Alphabetical Refe rence CLI referenc e A . 4 C L I re f e re n c e The basic CLI commands ar e divided int o the followi ng categori es: • Basi c co nt rol comma nds • M.
A-34 Zhone Technologies Model No. Running Head CLI reference Alphabetical Referenc e A.4.2 Movemen t and sear ch commands T able A-5 descr ibes the movement and sear ch commands. T able A-5. Movement and search commands Command Descript ion n G Go to command n .
Zhone Techn ologies / A-35 Alphabetical Refe rence CLI referenc e A.4. 3 Inse rt and ch ange co mmands T able A-6 descr ibes the ins ert and ch ange commands. 0 Move curso r to the b eginning of t he line. ^ Move curso r to the fi rst non-bl ank charact er .
A-36 Zhone Technologies Model No. Running Head CLI reference Alphabetical Referenc e A.4.4 Delete c ommands T able A-7 descr ibes the del ete commands. A.4.5 Put and undo comman ds T able A-7 descr ibes the put and undo commands . n r c R eplace following n charact ers with c.
Zhone Techn ologies / A-37 Alphabetical Refe rence CLI referenc e u Undo last command. T able A-8. Put and undo commands (Continued) Command Descript ion.
A-38 Zhone Technologies Model No. Running Head CLI reference Alphabetical Referenc e.
Zhone Technologi es / Index -1 Index A AC po w er, i nsta l lati on 3-5 access ing th e serial por t 4-5 acces sor ie s, de scri b ed 2-3 ACTIVEBANK1 command A-30 ACTIVEBANK2 command A-30 admi nist ra.
Index- 2 / Zhone Technolog ies D data por t defini ng drop and ins ert chann els A-24 data p ort l o opb a ck 5-4 activa ting 5-5 diagnos ing 5-4 DATE command A-30 DC po w er, i nsta l lati on 3-5 def.
Zhone Technologi es / Index -3 L latchi ng loo pbac k detec tion 5-1 LED Eth ernet 5-10 LED indica tors 5-9 Eth ernet 5-10 T1 5-10 WAN 5-3 LED s des crib ed 5- 9 Eth ernet 5-10 Powe r 5- 10 line l oop.
Index- 4 / Zhone Technolog ies read co mmunity st rings 4-6 SNMP tr ap re c ipien ts specif ying 4-6 SNM P trap s alar ms 4-6 enabl ing 4-6 spec ificat ions cabli ng 3-7 powe r 1-4, 3-4 temp eratu re .
Zhone Technologi es / Index -5 WAN LED green bli nking 5-3 WAN parame ter A-29 Y yell o w alar ms 4-6 Z Z Pl ex bene fits 1-2 featu res 1-2 management of 1-3 ove rview 1-1 power re quirements 3-4 spec.
Een belangrijk punt na aankoop van elk apparaat Zhone Technologies Z-PLEX-10-24-DOC-SC (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Zhone Technologies Z-PLEX-10-24-DOC-SC heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Zhone Technologies Z-PLEX-10-24-DOC-SC vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Zhone Technologies Z-PLEX-10-24-DOC-SC leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Zhone Technologies Z-PLEX-10-24-DOC-SC krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Zhone Technologies Z-PLEX-10-24-DOC-SC bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Zhone Technologies Z-PLEX-10-24-DOC-SC kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Zhone Technologies Z-PLEX-10-24-DOC-SC . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.