PRINTED IN UNITED STATES OF A MERIC A p/n 75844 Rev.D ECN-12851 M641 05 0705 cps 641 OWNERS MANUAL for E. B. C.™ Electronic Brew Control ™ DECANTER COFFEE BREWERS MOD EL S 1012 1040 1072 Includes: Installation Use & Care Servicing Instructions E.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFIC ATIONS Thank You for purc hasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FEATURES AND OPER ATING CONTROLS Fig. 1 Fe atures & Op erating Con trols 2 641 75844 Owners Manual E.B.C. Decanter.
PRECAUTIONS A ND GENERAL INFOR M A TION WA RNI NG: Electric S hock Ha zard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST ARTING THE INST ALLA TIO N Unpack the unit. Inspec t all components f or completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket (#33) and Spray Disk (#34) are properl y installed.
INSTALLATION INSTRUCTIONS (continued) NOTE : This equip ment m ust be installed to comply with all applicable f ederal, st ate and local plumbing codes and ordinances. WARNING: ELECTRIC SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard.
OPERATION Fig. 4 Brewer Operation Diagram A. ST ART- UP For initial start-up, or if the br ewer h as not been used f or an extended period of tim e: ♦ Be sure spray disk and brew gasket are properly installed in the brew head. ♦ Be sure the water supply is properly connected and the water supply valve is turned ON .
OPERATION (continued) 7 WATER HEATER W ater temperat ure is sensed by an electronic water temperature probe inserted into the water tank. This tempera ture signal is fed to th e controller.
8 OPERATION (continued) ELECTRONIC FEATURES Energizing the Brewer When electric power is applied to th e unit, all the li ghts will flash four times and four beeps will sound. The unit will be OFF . Press the ON/OFF key. Four beeps will sound and all lights will flash once.
OPERATION (continued) Quality Timer is normally set for 30 minutes. It can be set for 20 minutes by moving a jumper on the controller. See page 17. After Hours™ is an energ y saving f eature. T he brewer will enter After Hours™ mode if it is not used for three hours.
10 BREWING COFFEE CA UTI ON: Burn Hazard Exposed surfaces of the brewer, brew chamber and decanter m ay be HOT to the touch, and can cause serious burns. CA UTI ON: Burn Hazard To avoid splashing or overf l o wing hot liquids , ALWAYS place an empty decanter under th e brew chamber before starting the brew cycle.
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Brewe r PRECAUTIONS: D isconnect bre wer from electric po wer. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush. 1. Disconnect brewer from electric pow er.
TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check po wer supply cord Check / reset circuit breaker Turn on an d set fo r desired temp erature. See page 15 Allow to cool Examin e wiring & connec tors, controller, pow er board and heating element Repair/replace as needed Adjust controller.
CAUTION ELECTRIC SHOCK HA ZARD Live electrical circuits may be exposed while per form ing these procedures. These procedu re s are to be performed by qu alified technical personnel only.
SERVICING INSTRUCTIONS CA UTI ON Electric Shock Hazard Opening acc ess panels o r removing warmer plates on this brew ma y expose unins ulated electrical com ponents . Disconnect brewer from electrical power before removing any pane l or warmer plate.
SERVICING INSTRUCT IONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Remov e button plug from front panel. Pull vent tube out of tank lid an d insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power.
SERVICING IN STRUCTIONS (continued ) IMPORTANT: W ater pressure must be between 20 p.s.i and 90 p.s.i. f lowing pressure. If water pressure exceeds this value, or if water pressure varies gr eatly, a pres sure regulator must be insta l led in the water supply lin e.
SERVICING IN STRUCTIONS (continued ) 17 REPLACE SOLENOID Unplug pow er cord. Turn OFF and disconnect w ater supply from brewer inlet fitting. Remove front panel. Remove two screws h olding acces s door in place. Remove access door and solenoid. Unscrew inlet fitting cap to release solenoid from door.
REPLACE HOT WATER FAUCET COIL (Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.) Remove t ank lid ass embly per above. Remove two hex nuts hot water coil to cover. Pull coil f rom mounting holes. Reassemble in reverse order.
SERVICING IN STRUCTIONS (continued ) 19 Fig. 20 Keypad Ribbon Cable Hook -Up SET CONTROLLER JUMPERS Placing the jumper across Q1 se ts Quality Time at 20 Minutes. Placing the jumper across Q2 se ts Quality Time at 30 Minutes. Removing jumpers from both Q1 or Q2 disables Quality Timer.
CA UTIO N - CH EMICA L BURN HA ZA RD Deliming chem icals are caustic. W ear ap pr op riate prote ctive gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel.
7. Set the tank back into the brewer. Reassem b le the ta nk lid to the water tank. Make sure the gask et is properly in place, then reinstall the hold-do wn strap. 8. Reinstall w iring to heating element a nd thermostat. Reinstall the hi-lim it thermostat (if removed).
EXPLODED VIEW & PARTS LIST CABINET COMPONENTS - IN-LINE BREWERS 22 641 75844 Owners Manual E.B.C. Decanter.
EXPLODED VIEW & PARTS LIST (continued) ITEM PAR T NO. DES CRIPTION USED ON 1 8700-16 W armer Plate Black 1012, 1040 8875-149 W armer Plate Brown (optional) 1012, 1040 33 8543-42 Spray Head Gasket .
EXPLODED VIEW & PARTS LIST (continued) CABINET COMPONENTS - LO-PROFILE BREWERS 24 641 75844 Owners Manual E.B.C. Decanter.
EXPLODED VIEW & PART S LIST (continued) ITEM PART NO. DESCRIPTION USED ON 1 8700-16 W armer Plate Black 1072 8875-149 Warmer Plate Brown (optional) 1072 33 8543-42 Spray Head Gasket 1072 34 82727 .
EXPLODED VIEW & PART S LIST (continued) HOT WA TER TANK A SSEMBLY ITEM PART NO. DESCRIPT ION 13 8043-5 Hold Down Strap 14 8043-5 06 Nut, 8-32 SS Acorn 16 60366 Screw, 1/4-20 X 1-1/4 SS Cap Head 17.
ELECTRICAL COMPONENTS EXPLODED VIEW & PARTS LIST (continued) ITEM PART NO. DESCRIPT ION USED ON 31 1012 -10 Keypad 1012 1040 -10 Keypad 1040 1072 -10 Keypad 1072 35 8572 -18 Element, 120V 100W All.
EXPLODED VIEW & PARTS LIS T (continued) INTERNAL PLUMBING COMPONENTS ITEM PART NO. DESCRIPT ION USED ON 8 8540-3 Faucet Outlet T ube Assembly All 9 8540-4 For med Inlet Tube Assembly All 11 8572-2.
WIRING DIAGRAM 29 641 75844 Owners Manual E.B.C. Decanter.
WIRING DIAGRAM p/n 75373 30 641 75844 Owners Manual E.B.C. Decanter.
WIRING DIAGRAM (continued) 31 641 75844 Owners Manual E.B.C. Decanter p/n 75361.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu stri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T el ep hone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
Een belangrijk punt na aankoop van elk apparaat Bloomfield 1040 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bloomfield 1040 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bloomfield 1040 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bloomfield 1040 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bloomfield 1040 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bloomfield 1040 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bloomfield 1040 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bloomfield 1040 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.