Gebruiksaanwijzing /service van het product 2272 van de fabrikant Bloomfield
Ga naar pagina of 26
BLOO MFIEL D IND USTRI ES 2 ERIK CIRCLE, P .O .Box 280 V erd i, NV 89439 U.S.A. Custom er Service (775) 345- 0444 Ex t.502 fax ( 775) 34 5-0569 ww w .w el ls bl oom fi el d. co m OWNERS MANU AL LX DECANTER BREWER MODELS 2212 2216 2216EX 2272 2274EX Includes INSTALLAT ION OPERAT ION USE & CARE SERVICE p/n 74733 Rev.
All electrical equipment ma nufactured by BLOOMFIELD INDUSTRI ES is w arranted against d efects in m aterials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefi t of the original purchaser, except that: a.
ELECTRICAL SPECIFIC A TIONS* MODEL WAT TS VOLTS 1ø Hz CIRCUIT REQUIRED WIRE 2212 1800 120 50/60 15 AMP ( NEMA 5-15R ) 2 + ground 2216 3500 120/240 50/60 HARD WIRE TO CIRCUIT BREAKER 3 + ground 2272 1.
FEATURES & OPERATING CONTROLS 1. Brew Indicator Glows during brew cycle, flas hes in “Brew W ait” 2. Heat Indicator Glows when heating elem ents are energized 3. Power Indicator Glows when power is on 4. Warmer Indicators Glow when individual warmers are turned on 5.
PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels w hich require the use of tools. Failure to heed this w arning c an resu lt in electrical shock .
INSTALLATION INSTRUCTIONS RE A D THIS C A R EFULL Y BEFORE ST ARTING THE INST A LL A TION REFER TO EXPLODED VIEWS PAGES 16 thru 19 FOR COMPONENT NAMES/NUMBERS 1. Unpack the unit. Inspec t a ll components for comp leteness and condition. Ensure that all packing materials have been removed from the unit.
INSTALLATION INSTRUCTIONS (contin ued) NOTE: This equipment must be installed to comply with applica- ble f ederal, state and local codes and ordin a nc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard.
OPERATION To over-ride th e Br ew Wait mode , press and hold the BR E W key for 3 second s when the brewer is in Brew Wait mode (i.e. when brew light is flashing).
OPERATION (continued) WA R NI NG : Burn H azard. This applianc e dispenses very hot liquid. Serious bodily injury from scalding can occ ur from contact wi th dispensed liquids. CAUTION: Burn Hazard To avoid splashing or overflowing hot liqu ids, ALWAYS use an empty decanter before starting the brew cycle .
CLEANING INSTRUCTIONS CA UTI ON: Burn Hazard Brewing an d serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CA UTIO N: Electric Shoc k Hazard Do not submerge or i mmerse brewer in wat er. Do not pour or splash water into o r over air vents, control panel or warmer plates.
A. Adjust Brew Time B. Adjust Brew Temperature C. Adjust Quality Timer D. Adjust Dripout Timer E. Adjust After Hours Timer AB CD E UNDE R TOP COVER (IN SECO NDS) BREW TIME R (IN °F) BREW TEMP (I N 5 .
SERVICING INSTRUCTIONS — ELECTRICAL OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS 1. Pressing the PO W ER key energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is acco mplished via a FILL SOLENOID (32) and a W ATER LEVEL PROBE (7).
27 28 WARM ER MOUN TI NG 3 5 4 20 32 18 7 8 15 17 4 E-MA XLX ELECT RICAL COMPONENT 12 0V UNITS 12 0/2 40V UNITS SERVICING INSTRUCTIONS — ELECTRICAL 3 PROBE, TEMPERATURE (THERMISTOR) 4 THERMOSTAT,.
OPERATION SEE PAGE 13 FOR COMPONENT NAMES/NUMBERS 1. W ater enters at the inlet fi tting of the fill solenoid (32). The solenoid adm its water via a command from the controller. N OTE: The soleno id has an inter nal strainer. To clean the strainer: Shut off water supply.
SERVICING INSTRUCTIONS — PLUMBING 13 ITEM DESCRI PTION P ART N0. U SED ON 1 2 ASS E MBL Y , W A TER T ANK (120 V) 83500 2212, 22 72 6 GA SKE T , T AN K L ID 83 499 AL L 9 T ANK L ID 83 504 ALL 10 RET AINING CLIP , T ANK LID 83506 ALL 1 1 HOS E, OV ERFL O W (2 pc SILIC O NE 4.
SERVICING INST RUCTIONS — DE-LIMING HEA TER TANK 1. Disconnect br ewer form the electrical sup pl y. Turn off the water suppl y and disc onnect water suppl y from the brewer inlet fitting. 2. Remove the top panel or top wa rmer section to gain access to internal components.
SERVICING INSTRUCTIO NS — DIAGNOSTICS & TROUBLESHOOTIN G) If the E-Max™ LX goes into an error mode as outlined below , it will probably be necessary to reset the bre w er in order to test individual components.
EXPLODED VIEW — IN-LINE MODELS 16.
PARTS LIST — IN-LIN E MODELS 17.
EXPLODED VIEW — STEP-UP MODELS 18.
PA RTS LIST — STEP -UP M ODE L S 19.
WIRING DIAGRAM — IN-LINE MOD ELS 20.
WIRING DIAGRAM — I N-LINE EXPORT MODEL 21.
CONTROL BOARD 1 WP3 2 WP2 3 WP1 1 Heat er ( Line ) 2 Inlet ( Line) 3 Dump Line 4 Power (Line) 5 6 Dump (Neut) 7 Power (Neut) 8 Heater (Neut) Lin e Load Ga te Fr ont Wa rm er P late #2 120V 100 Watt Ma.
WIRING DIAGRAM — STEP-UP EXPORT MODEL 23.
Blo omfi eld Ind ustries , In c. Divis ion of Carri er Refrige r atio n In U S In C an ada PO Box 28 0, V e rdi, NV 89439 T el ephone: 775- 345-0444 Servi ce: 88 8-492-2782 Fax: 888-792-278 3 websit e: www . wellsbl oomfi eld.com T el ephone: 877- 507-1700 Servi ce: 90 5-507-1700 Fax: 905-507-1777 website: www .
Een belangrijk punt na aankoop van elk apparaat Bloomfield 2272 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bloomfield 2272 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bloomfield 2272 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bloomfield 2272 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bloomfield 2272 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bloomfield 2272 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bloomfield 2272 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bloomfield 2272 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.