663 OWNERS MANUAL for SA TELL ITE COFFEE BREWER wit h ELECTRO-MECH ANICA L CONTROL and EXTERNALLY HEATED SATELLITE SERVER MODEL : 9102A 9104A Includes: Installation Operation Use & Care Servicing Instructio ns Model 9102A Satellite Brewer with 9105SS Satellite PRINTED IN UNITED STATES OF A MERIC A p/n 76061 Rev.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS Thank You for pu rchasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R O L S 2 Fig 1. SS-1 Satellite Brewing System Features & Operating Controls 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
FEATURES AND OPER ATING CONTROLS (continued) Brewer Adjustable Legs Connector Hot W ater Faucet Name plate Control Panel Start Brew Sw itch Ready to Brew Indicator Stop Brew Swit ch War me r Sw itch T.
This appliance is inten ded for use in commer cial establishmen ts only. This appliance is inten ded to brew hot beverage, specif ically coffee, for human consumption.
5 INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with adjustable legs. Be sure all f our legs are securely screwed into the base of the brewer.
INSTALLATION INSTRUCTIONS (continued) 6 CA UTIO N: Electric Shock Hazard Brewer must be properly grounded to a reliable earth ground to prevent p ossible shock hazard. Do not assume a plumbing line will provide such a ground. Electrical shock may cause serious injury.
7 OPERATING INSTRUCTIONS Fig. 5 Control Panel Fig. 6 Brew Basket IMPORTANT: To avoid overflows, DO NOT start the brew cycle unless an EMPTY satellite is in place under the brew chamber. NOTE: The brew can be cancelled at any time by pressing the STOP sw it ch.
OPERATING INSTRUCTIONS (continued) 8 Fig. 7 W ater Fl ow Diagr am BREW & BY P ASS This brewer is a standard displacement brew er with pour-over optio n.
9 CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Turn POWER SW ITCH OFF. Allo w brewer to cool. FREQUENCY: Dail y TOOLS: Mild Detergent, Clean So ft Cloth or S ponge Bristle Brush 1. Turn POWER SWITCH OFF . Allow brewer to cool.
10 CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite PRECAUTIONS: Drain Satellite before Cleaning FREQUENCY: T wice Weekly TOOLS: Sight Glas s Brush, Sanitizer Soft Clean Cloth, Bucket 1. Remove and drain satellite. 2. Place 1 packe t of Sanitize r into 2-1/ 2 gallons of warm tap water.
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Will not heat or brew (no lights) Brewer not plugg ed in or circuit breaker tripped Reconnect brewer to electric power Reset circuit break er Main power switch off or damag ed Che ck.
12 SERVICING IN STRUCTIONS CA UTION : SHOCK HAZARD Disconnect brewer from electric power before opening any access panel. Note position of any wires or hoses before removing them from a panel. Wrench for Faucet Tubing ACCESS PANELS TOP PANEL is attached with two screws at the rear and a lip at the front.
13 CAUTION: SHOCK HAZARD Live electrical circuits are exposed during this procedure. Use care to avoid uninsulated electrical connectors. Adjustments to be performed by qualified technician only. NOTE: 1/8 turn = approx 10ºF (5.5ºC) TEMPERATURE A DJUSTMENT PRECAUTIONS: Disconnect br e wer from electric power.
SERVICING IN STRUCTIONS (continued ) 14 Adjustm ents to be perform ed by qualified te chnic ian only. NOTE: Brewer is pre-adjusted to deliver 1/2, 1 and/or 1-1/2 gallons of coffee at a wate r pressure of 50 p.s.i. Use this procedure to adjust the delivered volume to suit local conditions.
SERVICING INSTRUCTIONS (continued) 15 CA UTION : SHOCK HAZARD Disconnect brewer from electric power before opening the top panel. The bre wer is shipped f rom th e fact or y pre-set f or 25% bypass. This adjus tment mu st never be made unless the br ewer is installed on a soft w ater li ne, or a change in coffee strength is required.
CA UTIO N: CH EMICA L BURN HA ZA RD Deliming chem icals are caustic. W ear ap pr op riate pr ote ct ive gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th . This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel.
SERVICING INSTRUCTIONS (continued) 17 10. Reinstall tank lid assembl y into hot w ater tank. Make sure th e lid gasket is properly in place, then reinstall the hold- dow n clamp. 11. Remove spray disks and gaskets. Rinse both brew heads w ith clean water.
EXPLODED VIEW 18 PLUMBING COMPONENTS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
EXPLODED VIEW (continued) 19 ELECTRICAL COMPONENTS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
EXPLODED VIEW ((continued) 20 CABINET & RELATED COMP ONENT S 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
EXPLODED VIEW (continued) 21 SATELLITE A SSEMBLY 9105SS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
22 SERVICE KITS 663 76061 Owners Manual for 9102A Single Satellite Bre wer F AUCET REP AIR COMPONENTS 8268 0 Hex L o ck Nu t 85 5 1- 1 00 B 7 /1 6“ Lo ck Washe r 8268 1 Wash er 8255 6 Fauc et A ssem.
23 WIRING DIA GRAMS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
Blo omfi eld In dus trie s, Inc. Divisio n of Carri er Com m erci al Refrigerat i on In US and Canada T elephone: 775 -698- 5700 Fa x: 8 88 -492 -278 3 Fa x: 8 00 -356 -514 2 () website: www .
Een belangrijk punt na aankoop van elk apparaat Bloomfield 9102A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bloomfield 9102A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bloomfield 9102A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bloomfield 9102A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bloomfield 9102A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bloomfield 9102A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bloomfield 9102A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bloomfield 9102A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.