BLOOMFIELD INDUST RIES 2 ERIK CIRCLE , P . O. Box 280 V erdi , NV 8943 9 Cust omer Servi ce ( 775) 345 -0444 Ext .502 fax: (775) 345-0569 www .well sbl oomfi eld.
NOTE: For your protection, please note that equipmen t in this shipment was carefully inspected and packaged by skilled personnel befor e leaving the factory. Upon accep- tance of this shipment, the transp ortation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS Thank You for purcha sing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT UR ES AN D OP ER AT IN G CO N TR O LS 2 Fig 1. SS-2 Satellite Brewing System Features & Operating Controls.
FEATURES AND OPER A TING CONTRO LS (continued) Brewer Adjustable Legs Brewing Controls Digital Readout Bypass Nozzle Hot W ater Faucet Name plate Power Key System S w itch (not shown) Satellite Locato.
This appliance is inten ded for use in co mmercial e stablishments only. This appliance is inten ded to brew hot beverage, specif ically coffee, for human consumption.
5 INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with 4" adjustable legs and rubber feet. Be sure the legs are securel y screwed into th e base o f the br ew er, and that the rubber feet are properly installed. LEVEL THE UNIT The adjustable legs allow the brewer to be le veled.
INSTALLATION INSTRUCTIONS (continued) 6 IMPORTANT: Initial set-up must be performed by a qualified installer or qualified service technician. Improper set-up will damage the brewer an d void the warranty. DO NOT CONNECT POWER TO BREWER WITH SATELLITES IN PLACE.
7 NOTE: If water is not sensed at the water level sensor within 20 min ute s: Heater will be disabled Error message NO WATER SENSED will be displayed Call the PHONE NUMBER displayed for servic e. GETTING S TARTED Check the brewer and satellites: Check that the brewer is clean and the drip tray (if used) is em pty .
OPERATING INSTRUCTIONS (continued) Fig. 4 Operating Controls Fig. 5 Brew Basket CA UTIO N: Burn Hazard Basket and contents are hot to the touch and may cause burns on contact. BREWING CO FFEE Prepare the Brew Baskets: Make s ure the w ire rack is properly insta lled in eac h brew chamber.
9 OPERATING INSTRUC TIONS (continued) WAT ER FLOW Fig. 6 Wa ter Flow Diagram INLET The INLET VALVE is controlled by a signal from the CONTRO L BOARD. If the W ATER LEVEL PROBE does not detect water, the inlet solenoid is opened until w ater is again sensed.
CLEANING INSTRUCTIONS 10 CLEANING I NSTRUCTIONS CAUTION: Burn Hazard Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. WARNING: Electric Shock Hazard DO NOT immerse or submerge satell ites. Fluid may saturate the insulation and short-circuit the receptacle connectors.
11 CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite PRECAUTIONS: Drain Satellite bef ore Cleaning FREQUENCY: T w ice W eekly TOOLS: Sight Glass Brush, Saniti zer Sof t Clean Cloth, Bucket 1. Remove and drain sa tellites. Rem ove lids. 2. Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap water.
PROGRAMMING INSTRUCTIONS Fig. 7 Function Keys NEW MENU SETTINGS Menu Program: Press POWER key to enter OFF m ode. Press and hold 3rd & 6th keys for 3 seconds Advance thru m enus by pressing the 1s.
PROGRAMMING INSTRUCTIONS (continued) 13 PRECISE BREWING TEMPERATURE™: The brew cycle will not start until the water in the tank is at the proper t emperat ure. If START BREW key is pressed and held for 3 seconds du ring “ Brew Wait ” th e brew w ill proceed immediately .
ON/OFF – Normal Operation (Non A utomatic Ti mer): To turn the brewer OFF, press the POWER key: 2 beeps w ill be heard and the brewer will be turned OFF, indicated by all lights being off. To turn the brewer ON, press the POWER key: 2 beeps will sound, all lights will flash once, then the PO W ER LED will glow.
PROGRAMMING (continu ed) 15 Brew Volume The 1st key is the Standard Brew Volume. When a brew volume other than standar d brew volum e is selected, the Brewer will complete that brew then return to the standard brew volum e automatically.
PROGRAMMING (continued) The factory programming has the After Hours™ mode turne d OFF. W h ile in the After Hours mode, the POWER LED will flash continuously. Keypadlock™ deters unauthorized operation of the brew er. This feature is OFF in the standard factory settings.
17 TROUBLESHOOTING SUGGESTIONS DESCRIPTION OF PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY No lights or heat Unit not plugg ed in or circuit breaker tripped Reset circ uit break er Plug brewer into elec tr.
SERVICING IN STRUCTIONS 18 CA UTIO N - CH EMICA L BURN HA Z A RD Deliming chem icals are caustic. W ear appropriate pr otective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rmed by qualified and ex- perienced service personnel.
SERVICING INSTRUCTIONS (continued) 19 10. Reinstall tank lid asse mbly into hot w ater tank. Ma ke sure the lid gasket is properly in place, then reinstall the hold- down clamps. 11. Rem ove spray disks and gaskets. Rinse both brew heads with clean water.
EXPLODED VIEW C ABINET AND EXTERIOR COMPONENTS 20.
21.
EXPLODED VIEW I NTERIOR COMPONENTS 22 26 32 38 39 36 33 3 41 1 14 30 29 21 19 16 17 47 18 5 8 6 7 37 42 43 45 31 3 9 15 40 48 49 30 34 46 10 34 50 13 4 27 3 28 24 22 44 12 25 27 20 35 11 2 23 29.
23 ITEM SERVICE # DESCRIPTION QTY 1 84427 VALVE ASSEMBLY 1 2 83778 RETAINING CLIP TANK LID 4 3 NUT KEP 8-32 SS 22 4 8043-12 GASKET COVER TANK 1 5 8812-57 FITTING UNION 1/4 x 1/4 1 6 8710-10 NUT HEX BR.
24 WIRING DIAGRAM.
25 SATELLITE EXPLODED VIEW & PARTS LIST SATE LLI TE MO DEL 9 440 ITEM P ART NO. DESCRIP TION QTY 1 WELDMENT , SA T ELLITE 1 2 83863 T A NK LID ASSY 1 3 84313 HANDLE / F A UCET GUARD 1 4 84341 F AUCET & SHANK ASSY 1 4.1 84390 F AUCET , MODEL ES 1 4.
Bloo mfie ld Indust ri es, Inc. Divisi on o f Carr ier Re friger ation Bloo mfie ld In dust ries Canad a Li mite d Divisi on o f Carr ier Re friger ation PO. B ox 280 V erdi, NV . 89439 T eleph one ( 775)3 45-044 4 Serv ice: (888) 492-27 82 website: www .
Een belangrijk punt na aankoop van elk apparaat Bloomfield 9421 (SS2-HE) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bloomfield 9421 (SS2-HE) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bloomfield 9421 (SS2-HE) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bloomfield 9421 (SS2-HE) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bloomfield 9421 (SS2-HE) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bloomfield 9421 (SS2-HE) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bloomfield 9421 (SS2-HE) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bloomfield 9421 (SS2-HE) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.