Gebruiksaanwijzing /service van het product IR100SLM van de fabrikant ACTiSYS
Ga naar pagina of 20
The W ir eless Connectivi ty Expert 4851 1 W arm Springs Blvd., Su ite 206, Frem ont CA 9453 9 T el : (510) 490-802 4 Fax: (510) 62 3-7268 We b s i t e : http://www .
- 1 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 FCC & VCCI Compliance Statement This device c omplies with p art 15 of the FCC Rules.
- 2 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 T ABLE OF CONTENTS PRECAU TIONS........................................................................................................... 3 1. Featarus........................
- 3 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 PRECA UTIONS T o ensure trouble-free operation, please observe the following precautions: Optical communications are easily af fected by external light sources, weak batteries, transfer distance, transfer angle, etc.
- 4 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 1. Features Support IrDA standard including: - Ir LAP - IrLM P - T iny TP - I r C O MM - IrOBEX transport Other standards: - IrLP T IrDA baud rate supported: - 9.6kbps - 19.2kbps - 38.
- 5 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 Host interface baud rate supported: - 1.2kbps - 2.4kbps - 4.8kbps - 9.6kbps - 19.
- 6 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 75L V47 37 IR8200IC IR220V ACF TXDO /RXDI / MODE / RESET /RXD0 /TXD 0 Optic al T ransceiver /TX D1 /RXD1 /RT S1 /CTS1 /DSR1 /DTR1 /CD1 /RI1 /RTS0 /DTR0 /RXDO /TXD I EEPRO M RTS CTS DSR DTR CD RI TXD RXD SEL0 SEL1 SEL2 : : /RT S1 /CTS1 /DSR1 /DTR1 /CD1 /RI1 /TXD /RXD 2.
- 7 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 3. A pplicat ions 3.1 Embedded IrDA protocol stack The mandatory IrDA protocol layers, Ir LAP (comply with TEST frame capability requir ement) and IrLMP (including IAS) are handled by ACT-IR100S-L/LM, In addition, Ti nyTP , IrCOMM, IrLPT , IrOBEX transport are all included.
- 8 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 I r L M P a n d I A S IrLAP IrLPT or IrCOM M 3- wire r aw IrCOMM 9-wire TinyTP OBEX T rans p ort Tiny TP HOST IrPHY encoder-d.
- 9 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4. Operation Setting, EEPROM, and other optional hardware 4.1 Serial EEPROM There are some special functions i f t he external serial EEPROM installed. The optional serial EEPROM allow users to set ”Host Speed” and “Hardware Flow Control and Connection Control”.
- 10 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.2 Baud Rate Setting Jumpers SEL0-2 and serial EPROM setting s are used to set the hos t interface RXD and TXD data rate. Note that this is independent of the IrDA connection data rat e.
- 11 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.3 Ignore DSR SEL3 open (SEL3=1) m eans i g n o r e t he ph y sical DSR inpu t, p r e t end t h a t DSR is on. This logical DSR is always used for connection control. The physical DTR is used f or connection indicat ion.
- 12 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.5 EEPROM Function Disable Jumper SEL7 is use to enable or disable EEPROM f unct ion. If this function disable, IR100S-L/ L M will use SEL0~SEL4 setting only . If this function enable, IR100S-L/LM will use EEPROM setting and jumpers SEL0~SEL4 a re ignored.
- 13 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.6 On Line Change Host Speed and Hard w are Flow Control/Connection Control The ACT-IR100S-L/LM allowed user to change Host Speed or Hardware Flow Control/Connection Control in run tim e.
- 14 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.7 RS-232C DTE DB-9P Connector Pin No. Name Descriptions I/O 1 CD Data Carr ier Det ect I 2 RXD Receiver Data I 3 TXD Trans.
- 15 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 5. How to Connect IR100S-L/LM with host Device IR100S-L/LM uses a standard RS232 D TE port to connect with the host. If the host dev ice is a Modem like device and has a RS232 DCE port, then use a "straight cable".
- 16 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 IR100S-L TXD RXD RTS CTS DSR DTR CD RI GND DTE RXD TXD CTS RTS DT R DS R CD RI GND If the host device is a PC like device and has a RS232 DTE port too, then you need to use a "Null Modem" connection betw een the t wo.
- 17 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 OTHER ACT iSYS IrDA PRODUCTS I (A CT-1 ): IrDA Primary Statio n Pro toco l Stack !" IrLAP, IrLMP, IAS and o ptional T iny TP, IrCOM M, IrM C, IrTr an-P, etc.. !" For PDA, d igita l cam era, handhel d data t erm inal, pal mtop c omputer, sm ar t phone.
- 18 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 THE FOLLOWING W ARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHT S THAT VARY FROM STATE TO STATE.
- 19 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 Copyright 199 5-2001 ACT iSYS Corp. 4851 1 W arm Springs Blvd, Suite 206, Fr em ont, CA 94539, USA T el:+1-510-490-8024 Fax:+1-510- 623-7268 Internet: irda-info@act isys.
Een belangrijk punt na aankoop van elk apparaat ACTiSYS IR100SLM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ACTiSYS IR100SLM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ACTiSYS IR100SLM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ACTiSYS IR100SLM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ACTiSYS IR100SLM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ACTiSYS IR100SLM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ACTiSYS IR100SLM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ACTiSYS IR100SLM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.