Instruction Manual SAVE THIS MANU AL FOR FUTURE REFERENCE. Questions? Contact Cust omer Suppor t at ( 8 77) 22 1 - 1 25 2 or visit www . AcuRite .com. CONTENTS Unpac king Instr uctions ........... 2 P ackage Contents .................. 2 Product R egistration .
2 Congratulations on y our new A cuRite product. T o ensure t he best possible product perf ormance, please read t his manual in its entirety and retain it for future ref erence. Unpac king Ins tructions Remo v e the protective lm t hat is applied to the LCD screen prior to using this product.
3 Features & Benets 7 2 1 9 8 10 5 6 11 4 3 5-IN-1 SENSOR 1 . Rainfall Collector Funnel 2. Solar Cell Panel Conv er ts sunlight into pow er to run internal aspirating f an. Internal Aspirating Fan (not sho wn) Draws ambient air into sensor to reduce solar radiation heating, resulting in more accurate temperature measurement.
4 Features & Benets Display Unit 10 37 11 12 9 28 29 31 33 30 32 1 3 4 5 7 8 6 2 19 20 21 22 23 25 26 27 24 36 34 13 14 16 15 17 18 35.
5 1 . Peak Wind Speed Highest speed from past 60 minutes. 2. Wind Speed Alarm On Indicator 3. Average Wind Speed of all speeds from past 2 minutes. 4. Pressure Hist or y Graph Current pressure on right wit h trend (Rising, Steady or Falling). 5. Historical Barometr ic Pressure Pressure reading 1 2 hours ago.
6 Bac k of Display Unit BACK OF DISPL AY UNIT 1 . A-B-C Switc h ID code that must matc h 5-in-1 sensor ’s A -B-C switc h to ensure units synchronize. 2. Clear T oday Clears data recorded since 1 2:00am. 3. Reset Full reset to factor y defaults. 4. Clear All Clears all data recorded without having to reset time and date.
7 A B C SETUP 5-in-1 Sensor Setup 1 A-B-C Switch Set to matc h display unit 2 Install Batteries 4 AA Batteries 3 Rain Gauge Stabilizer Remo ve and discar d Set the A-B-C Switc h Locate t he A -B-C switc h inside t he batter y com par tment. Set t he A -B-C switc h to A , B or C.
8 Set the A-B-C Switc h The A -B-C switc h is located inside the batt er y compar tment. It can be set to A , B or C. Ho we v er , you must select the same letter c hoices for bot h the sensor and the displa y unit in order for the units to sync hronize.
9 Set t he Time & Dat e The cloc k and calendar are utilized to time stamp histor y records and other data, so it is impor t ant to set t he time and date soon af t er you po w er on the display unit.
10 Select Measurement U nits T o select be tween standard units (mph, ºF , e tc.) or metric units (kph, ºC, e tc.): 1 . Press the “ ▲ ” or “ ▼ ” buttons until “SET UNITS?” is displayed on the Selectable Categor y part of t he display unit.
11 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding envir onmental conditions. Proper placement of bot h the display unit and t he sensor are critical t o the accuracy and per for mance of this product. Display Unit Placement Place the displa y unit in a dr y area free of dir t and dust.
12 5-in-1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount t he sensor at least 5 fee t (1 .5 met ers) of f the ground (higher is better for wind measurement) in an open area.
13 OPERATION Using t he Professional Weat her Center Learning Mode Self-Calibrating Forecasting use a unique algorithm t o analyze c hanges in pressure o v er a time period (called Lear ning Mode) to deter mine your altitude. Af ter 1 4 days, t he Learning Mode icon disappears from the displa y screen.
14 Prog rammable Weat her Alarms Eac h Selectable W eat her Categor y f eatures an alarm option. When an alarm sounds, t he display unit emits an audible beep and ashes t he af fected categor y, its alarm settings, and any other relev ant data. Some alarms can be customized t o aler t you when y our progr ammed value is reached.
15 T o activ ate or deactivat e an ala rm: Press “ ” T o set or adjust an alarm value: Press and hold “ ” Set a Weather Alar m 1 . Choose t he weather categor y for which you wish to set an alar m by pressing the “ ▲ ” or “ ▼ ” buttons until t he categor y is displa yed on the Selectable Categor y part of t he display unit.
16 Problem Possible Solution No outdoor sensor reception no bars • Relocate the display unit and/or t he 5-in-1 sensor . The units must be within 330 f t (1 00 m) of each ot her .
17 Problem Possible Solution Inaccurate temperature or humidity • Make sure both the displa y unit and sensor are placed away from heat sources or v ents (see p. 1 1). • Make sure both units are positioned away from moisture sources (see p. 1 1). • Make sure sensor is mounted at least 5 ft of f t he ground.
18 Care & Maintenance Display Unit Car e Clean with a sof t, dam p cloth. Do no t use caustic cleaners or abrasiv es. K eep away from dust, dirt and moisture. Clean ventilation por ts regularly wit h a gentle puf f of air . 5-in-1 Sensor Care Clean the Sensor Clean with a sof t dam p cloth.
19 3. Press the ” ▲ “ and ” ▼ “ buttons to calibrate t he data value higher or lo wer from the actual reading. 4. Press the “SET” button to conr m t he calibration adjustment. Note: The “C AL ” icon remains illuminated next to calibrated values.
20 FCC Information This device complies with par t 1 5 of FCC r ules. Operation is subject to the following two conditions: 1- This device may NOT cause harmful interf erence, and 2- This device must accept any interference received, including inter ference that ma y cause undesired operation.
21 At AcuRite, we proudly uphold our commitment to quality tec hnology . Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase.
22.
23.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy- rights are the property of their respective owners. AcuRite uses patented technology . Visit www .
Een belangrijk punt na aankoop van elk apparaat Acu-Rite 1010 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Acu-Rite 1010 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Acu-Rite 1010 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Acu-Rite 1010 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Acu-Rite 1010 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Acu-Rite 1010 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Acu-Rite 1010 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Acu-Rite 1010 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.