2 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange.
Applications Manual Bosch Gr eenstar | 3 Bosch Thermot echnology Corp. Data subject to c hange T able of Contents 1 Information about the appliance 4 1.1 Boiler types and sizes 4 1.2 FW200 Boiler Energy Management 5 1.3 FB100 Remot e Control & Room Sensor 6 1.
4 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 1 Information about the appliance 1.1 Boiler types and sizes Greenstar Heating boilers Greenstar 57: Z.
Applications Manual Bosch Gr eenstar | 5 Bosch Thermot echnology Corp. Data subject to c hange 1.2 FW200 Boiler Energy Management Syst em The Boiler Energy Management Syst em includes the FW200 user programming int er face with integrat ed outdoor reset contr ol.
6 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 1.3 FB100 Remote Contr ol & Room Sensor The FB100 can only be connect ed to sy stems with FW200 and a boiler with BUS-enabled Heatronic 3.
Applications Manual Bosch Gr eenstar | 7 Bosch Thermot echnology Corp. Data subject to c hange 1.4 IPM2 Space Heating Module The IPM2 module operates pum ps and mixing valves of 2 heating zones. Each zone is run independently based on the programming and f eedback from the FB100 room sensor (if installed).
8 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 1.5 ISM2 Solar Module The ISM2 module controls the com ponents of a solar thermal syst em.
Applications Manual Bosch Gr eenstar | 9 Bosch Thermot echnology Corp. Data subject to c hange 2 Applications Legend Greenstar boiler Greenstar combi-boiler Greenstar Greenstar pipe pipe Flow check valve Fig. 3 Legend NOTICE: All drawings in t his manual are conceptual in natur e and only depict components r elevant f or the syst ems shown.
10 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange List of most common applications Single Zone Baseboard Syst ems: Syst em 1: Greenstar Heating Boiler in a single zone syst em (page 13-16). Syst em 2: Greenstar Combi-Boiler in a single zone syst em (page 17-20).
Applications Manual Bosch Gr eenstar | 11 Bosch Thermot echnology Corp. Data subject to c hange Boiler pump capacity in single zone syst ems When installing the boiler in a single zone application without primar y/secondar y piping, it is critical not to overload t he pump.
12 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 02 5 7 8 14 36 15 20 25 10 5 0 H / ft . V / gpm 1 2 3 4 400 800 1200 1600 200 600 1000 1400 7 0 6 5 4 3 2 1 0 H / m . V / l/h 6 720 641 933-59.1O 1 2 3 4 02 13 5 46 8 7 15 20 25 10 5 0 H / ft .
Applications Manual Bosch Gr eenstar | 13 Bosch Thermot echnology Corp. Data subject to c hange 2.1 Syst em 1: Greenstar Heating Boiler in a single zone syst em Summar y: Single boiler supplying one baseboard heating zone equipped with FW200 outdoor rese t controller with built-in room sensor in the living space.
14 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 1 - Piping Diagram.
Applications Manual Bosch Gr eenstar | 15 Bosch Thermot echnology Corp. Data subject to c hange System 1 - Wiring Diagram.
16 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 1: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 17 Bosch Thermot echnology Corp. Data subject to c hange 2.2 Syst em 2: Greenstar Combi Boiler in a single zone syst em Summar y: Single combi-boiler supplying one baseboard heating zone equipped with FW200 outdoor rese t controller with built-in room sensor in the living space.
18 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 2 - Piping diagram.
Applications Manual Bosch Gr eenstar | 19 Bosch Thermot echnology Corp. Data subject to c hange System 2 - Wiring diagram.
20 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 2: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 21 Bosch Thermot echnology Corp. Data subject to c hange 2.3 Syst em 3: Greenstar Heating Boiler in a single zone syst em with DHW tank loading Summar y: Single boiler supplying one baseboard heating zone equipped with FW200 outdoor rese t controller with built- in room sensor in the living space.
22 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 3 - Piping diagram.
Applications Manual Bosch Gr eenstar | 23 Bosch Thermot echnology Corp. Data subject to c hange System 3 - Wiring diagram.
24 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 3: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 25 Bosch Thermot echnology Corp. Data subject to c hange 2.4 System 4: Greenstar Heating Boiler in a single zone syst em with solar thermal DHW and boiler backup.
26 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 4 - Piping diagram R1.
Applications Manual Bosch Gr eenstar | 27 Bosch Thermot echnology Corp. Data subject to c hange System 4 - Wiring diagram R1.
28 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 4: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 29 Bosch Thermot echnology Corp. Data subject to c hange 2.5 System 5: Greenstar Heating Boiler in a single zone syst em Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone.
30 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 5 - Piping diagram.
Applications Manual Bosch Gr eenstar | 31 Bosch Thermot echnology Corp. Data subject to c hange System 5 - Wiring diagram.
32 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 5: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 33 Bosch Thermot echnology Corp. Data subject to c hange 2.6 System 6: Greenstar Combi Boiler in a single zone syst em Summar y: Single combi-boiler supplying one heating zone. Outdoor reset wit h FW200 controller with built-in r oom sensor mounted in t he living space for r oom feedbac k.
34 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 6 - Piping diagram.
Applications Manual Bosch Gr eenstar | 35 Bosch Thermot echnology Corp. Data subject to c hange System 6 - Wiring diagram.
36 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 6: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 37 Bosch Thermot echnology Corp. Data subject to c hange 2.7 System 7: Greenstar Heating Boiler in a single zone syst em with DHW tank loading Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone.
38 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 7 - Piping diagram.
Applications Manual Bosch Gr eenstar | 39 Bosch Thermot echnology Corp. Data subject to c hange System 7 - Wiring diagram.
40 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 7: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 41 Bosch Thermot echnology Corp. Data subject to c hange 2.8 System 8: Greenstar Heating Boiler in a single zone syst em with room thermostat and DHW tank loading Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone.
42 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 8 - Piping diagram.
Applications Manual Bosch Gr eenstar | 43 Bosch Thermot echnology Corp. Data subject to c hange System 8 - Wiring diagram.
44 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 8: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence.
Applications Manual Bosch Gr eenstar | 45 Bosch Thermot echnology Corp. Data subject to c hange 2.9 System 9: Greenstar Heating Boiler in a single zone syst em with solar thermal DHW and boiler backup Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone.
46 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 9 - Piping diagram R1.
Applications Manual Bosch Gr eenstar | 47 Bosch Thermot echnology Corp. Data subject to c hange System 9 - Wiring diagram R1.
48 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 9: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone.
Applications Manual Bosch Gr eenstar | 49 Bosch Thermot echnology Corp. Data subject to c hange 2.10 System 10: Greenstar Heating Boiler with zone pumps and room thermostats Summar y: Single boiler with primar y/secondar y piping con fi gura- tion supplying multiple heating zones.
50 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 10 - Piping diagram.
Applications Manual Bosch Gr eenstar | 51 Bosch Thermot echnology Corp. Data subject to c hange System 10 - Wiring diagram.
52 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 10: Setup and Pr ogramming In this dual zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence on the heating cur ve.
Applications Manual Bosch Gr eenstar | 53 Bosch Thermot echnology Corp. Data subject to c hange 2.11 System 11: Greenstar Heating Boiler with zone pumps, rela y panel, room thermostats and DHW tank lo.
54 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 11 - Piping diagram.
Applications Manual Bosch Gr eenstar | 55 Bosch Thermot echnology Corp. Data subject to c hange System 11 - Wiring diagram.
56 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 11: Setup and Pr ogramming In this multi zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence on the heating cur ve.
Applications Manual Bosch Gr eenstar | 57 Bosch Thermot echnology Corp. Data subject to c hange 2.12 System 12: Greenstar Heating Boiler with zone valves and room thermostats Summar y: Single boiler with primar y/secondar y piping con fi gura- tion supplying three heating zones contr olled by 3rd par ty room thermostats with zone valv es.
58 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 12 - Piping diagram.
Applications Manual Bosch Gr eenstar | 59 Bosch Thermot echnology Corp. Data subject to c hange System 12 - Wiring diagram.
60 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 12: Setup and Pr ogramming In this multi zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence on the heating cur ve.
Applications Manual Bosch Gr eenstar | 61 Bosch Thermot echnology Corp. Data subject to c hange.
62 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange.
Applications Manual Bosch Gr eenstar | 63 Bosch Thermot echnology Corp. Data subject to c hange.
United Stat es and Canada Bosch Thermotechnology Corp. 50 Wentw orth Avenue Londonderry, NH 03053 T el: 603-552-1100 F ax: 603-584-1681 www.bosch-climat e.
Een belangrijk punt na aankoop van elk apparaat Bosch Appliances Boiler (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bosch Appliances Boiler heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bosch Appliances Boiler vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bosch Appliances Boiler leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bosch Appliances Boiler krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bosch Appliances Boiler bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bosch Appliances Boiler kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bosch Appliances Boiler . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.