EN Installation Guide Dialer Capture Ethernet Module Conettix C900V2.
Conettix C900V2 | Installation Guide | Trademarks 2 Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 Trademarks Altronix ® is a registered trademark of Altronix Corporation. Phillips ® is a registered trad emark of Phillips Screw Company in the United States and other coun tries.
Conettix C900V2 | Installation Guide | Contents . Bosch Securit y Systems, Inc. | 8/ 08 | F0 1U087780 -01 3 Contents 1.0 Introduc tion ..................................................4 2.0 Installati on ..............................................
Conettix C900V2 | Installation Guide | Contents 4 Bosch Secur ity Systems, I nc. | 8/08 | F01U08 7780-01 1.0 Introductio n The Conettix C900V2 Dialer Capture Ethernet Module (referred to as the C900V2) links the digital dialer (data output) from a control panel to an Ethernet connection on a local area network (LAN) or wide area network (WAN).
Conettix C900V2 | Installation Guide | Contents . Bosch Securit y Systems, Inc. | 8/ 08 | F0 1U087780 -01 5 Figure 2: Optional Mounting Plate 3 A 3 2 4 6 6 5 1 3. Place the top edge of the C900V2 (4) under the standoff bracket of the top two s tandoffs (1).
Conettix C900V2 | Installation Guide | Contents 6 Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 2.2 Wiring Figure 5: Wiring to a DS7400Xi in the Same Enclosure 3 1 7 5 4 10 8 2 9 6 1 – C900V2 2 – To LAN or WAN port 3 – DS7400Xi Control Panel 4 – Non-power limited area NOTE: All power limited wi ring must be at least 6.
Conettix C900V2 | Installation Guide | . Bosch Securit y Systems, Inc. | 8/ 08 | F0 1U087780 -01 7 2.3 Input Functions The C900V2 has three inputs monitored by analog- to-digital (A/D) converters: • Input 1 (IN1): Used as an en d-of-line (EOL) supervised loop.
Conettix C900V2 | Installation Guide | 3.0 Setup 8 Bosch Securi ty Systems, Inc. | 8 /08 | F0 1U087780 -01 2.7 Ethernet Connection One of the RJ-45 jacks connect s the C900V2 to the Ethernet Network (LAN or WAN). The connector pins are listed in Table 3.
Conettix C900V2 | Installation Guide | 3.0 Setup . Bosch Securit y Systems, Inc. | 8/ 08 | F0 1U087780 -01 9 Table 4: Digital Dialer Protocol (DIP Switches 1 through 4, and 10) DIP Switches 10 1 2 3 4.
Conettix C900V2 | Installation Guide | 3.0 Setup 10 Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 Table 5: DIP Switches 5 through 9 Switch State Function 5 ON Enable auto Fal lback Mode after detecting an i ntercept error. 1 OFF Disabl e auto Fallback Mod e after detecting an intercept error.
Conettix C900V2 | Installation Guide | 3.0 Setup . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 11 Table 6: System LED Functions Color State Function None Off No power. Green Solid C900V2 failed. Flashing (5 Hz) The recei ver is resp onding normally.
Conettix C900V2 | Installation Guide | 3.0 Setup 12 Bosch Security S ystems, Inc. | 8/0 8 | F01U0 87780-0 1 3.4 Fallback Mode In fallback operation, the C900V2 connects the PSTN directly to the dialer, bypas sing itself from the phone c ircuit. Intercept Mode is maintained only if the C900V2 processor operates and there are no errors.
Conettix C900V2 | Installation Guide | 4.0 C900V2 Configuration Setup In structions . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 13 4.0 C900V2 Configurati on Setup Instructions 4.
Conettix C900V2 | Installation Guide | 4.0 C900V2 Configuration Setup Instructions 14 Bosch Securi ty Systems, I nc. | 8/08 | F0 1U08778 0-01 The IP and MAC addresses in this procedure are examples and are not the same as those for your C900V2. 1. Select Start Æ Run .
Conettix C900V2 | Installation Guide | 4.0 C900V2 Configuration Setup In structions . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 15 After a few seconds, an error message appears. 4. Click OK to clear the message. The Telnet window appears again.
Conettix C900V2 | Installation Guide | 4.0 C900V2 Configuration Setup Instructions 16 Bosch Security S ystems, Inc. | 8/0 8 | F01U0 87780-0 1 5. Press [ENTER]. Th e Setup Mode information appears. Continue with Section 4.5.3 Configuration Using Telnet .
Conettix C900V2 | Installation Guide | 4.0 C900V2 Configuration Setup In structions . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 17 7. Type 1 and press [ENTER] to s et up Channel 1 configuration.
Conettix C900V2 | Installation Guide | 5.0 Anti-Substitution Protection 18 Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 28. At the C: > prompt, type ping <IP A ddress> and press [ENTER]. Four reply messages are received, confirming the C900V2 is com municatin g on the n etwork.
Conettix C900V2 | Installation Guide | 6.0 UL Standard 1610 and ULC S304 Intrusion System In stallations . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 19 6.
Conettix C900V2 | Installation Guide | 6.0 UL Standard 1610 and ULC S304 Intrusion System Installations 20 Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 Figure 12: C900V2 and Generic Control.
Conettix C900V2 | Installation Guide | 6.0 UL Standard 1610 and ULC S304 Intrusion System In stallations . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 21 Table 10: Connection Sequence – .
Conettix C900V2 | Installation Guide | 6.0 UL Standard 1610 and ULC S304 Intrusion System Installations 22 Bosch Security S ystems, Inc. | 8/0 8 | F01U0 87780-0 1 6.2 Pro tected Premises Control Panel with Digital Dialer Ba ckup 1. Use the D6200 Software to set th e poll rate on the C900V2.
Conettix C900V2 | Installation Guide | 7.0 UL Standard 864 for Fire System Installation s . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 23 7.0 UL Standard 864 for Fire System Installatio ns To install the C900V2 in com pliance with UL 864 for Fire Syst em Installations, you must sati sfy all requirements in th is section.
Conettix C900V2 | Installation Guide | 7.0 UL Standard 864 for Fire System Installations 24 Bosch Securi ty Systems, I nc. | 8/08 | F0 1U08778 0-01 Figure 13: C900V2 and Generic Control Panel in Separ.
Conettix C900V2 | Installation Guide | 7.0 UL Standard 864 for Fire System Installation s . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 25 Table 11: Connection Sequence – C900V2 and Gene.
Conettix C900V2 | Installation Guide | 8.0 Specification s 26 Bosch Security S ystems, Inc. | 8/0 8 | F01U0 87780-0 1 8.0 Specifications Table 12: Specifications Voltage Rang e 12 VDC to 24 VDC, nomi nal Current 280 mA, maximum Dimensions 17.8 cm x 11.
Conettix C900V2 | Installation Guide | Appen dix : C900V2 Compatib le Data Formats . Bosch Securit y Systems, Inc. | 8/ 08 | F01U0 87780 -01 27 Appendix : C900V2 Compatibl e Data Formats Table 13: Com.
© 2008 Bosch Security Systems, Inc. F01U087780-01 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 1 4450-9199 (800) 289-0096.
Een belangrijk punt na aankoop van elk apparaat Bosch Appliances C900V2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bosch Appliances C900V2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bosch Appliances C900V2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bosch Appliances C900V2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bosch Appliances C900V2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bosch Appliances C900V2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bosch Appliances C900V2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bosch Appliances C900V2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.