Gebruiksaanwijzing /service van het product DS7447E van de fabrikant Bosch Appliances
Ga naar pagina of 100
Reference Guide for the DS7400Xi (V er . 4+) Control/Communicator T urning On (arming) your System using the DS7445/DS7445i or DS7447/DS7447E Keypad Normal Arming [PIN] + [On] Perimeter Arming, no ent.
Page 2 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide T able of Contents Keypad Quick Reference Guide ........................................ 1 1.0 Specifications ......................................
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 3 10.16 Commercial Fire Mode Programming: Program Address (2733) ............................................. 4 8 10.17 Open/Close Report Control Programming: Program Address (3149) .
Page 4 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 1.0 Specifications 1. 1 Enclosure Housing The standard enclosure is manufactured from 20 Guage (1.0 mm), cold-rolled steel, and measures 12.5 by 14.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 5 1.16 Backup Battery Calculation • The following table is used to calculate the standby battery capacity required by NFP A when using the DS7400Xi: 1.
Page 6 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 1.18 Options • DS7412: RS232 Serial Interface module. The DS7412 module allows the panel to send event information, in an ASCII format, directly to a serial printer or computer .
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 7 • DS7460: Dual Zone Module (up to 60 per system. Requires a DS7430 Multiplex Expansion Module). The DS7460 provides a means of monitoring conventional Normally Open or Normally Closed contacts.
Page 8 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 2.0 Enclosure Installation The DS7400Xi control/communicator and the enclosure are shipped together . The control, however , still needs to be installed into the enclosure.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 9 T he Batt ery T erminal s and Wi res are NO T Power L imi ted. A ¼ i n. (6.4 m m) spacing m u s t be m aint ai n ed betw een t he batt ery ter mina l s, batt ery wir i ng and all other w iring.
Page 10 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 3.0 Control T erminal W iring NO Typical b urglar alarm loop wiring Z– L+ Typical 2-wire smoke detecto r wir i n g Z– L+ Ala rm Powe r ++ – Loop + or PO 2 Zone Inpu t Aux .
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 11 4.0 Hardware Layout Example Armed St at u s Pow er Fir e 1 23 45 6 78 9 0 * # On No Ent ry Syst.
Page 12 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 5.0 System Worksheet A c c o u n t N u m b e r I n f o r m a t i o n Name Contact Perso n Addr e.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 13 5. 0 System Worksheet (continued) P e r s o n a l I d e n t i f i c a t i o n N u m b e r I n f o r m a t i o n PI N I n for mati on U s e r P in # A u th .
Page 14 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 5. 0 System Worksheet (continued) P e r s o n a l I d e n t i f i c a t i o n N u m b e r I n f .
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 15 5. 0 System Worksheet (continued) Ex am p le Type * Zone /Output Partitio n & Locati on Func tion # Zone # 1 Zone Loc at ion a n d N ot es Zn Func t.
Page 16 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 5. 0 System Worksheet (continued).
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 17 5. 0 System Worksheet (continued).
Page 18 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 5. 0 System Worksheet (continued) Zone Location and Notes Worksheet.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 19 6.0 Glossary 6. 1 General Control Programming • Normal Arming - [PIN] + [On]: If programmed, arms the entire system while allowing entry delays for entry/exit zones.
Page 20 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide • Entry/Exit Delay #2: This is a zone programmed to behave identical to the Entry/Exit Delay #1 zone function except that it uses entry delay time #2 (address 4029).
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 21 - Smoke alarm . This must be the odd numbered zone of the zone pair required for these devices. The zone must be programmed with a zone function that is set for Fire Zone and Trouble on Open.
Page 22 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide - For example: When using only one partition, it is partition one. When using three partitions, they are partitions one, two, and three. - Partitioning allows the system to act as up to 8 different systems.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 23 • Pulsing Fire Zone : This is a zone programmed to output a pulse for a fire alarm in the normal manner (one second ON, one second OFF).
Page 24 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide • Low Battery : This report is sent when a low battery condition occurs. • Battery Restoral : This report is sent when a low battery condition restores.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 25 6.16 FCC Compliance Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Page 26 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 7.0 Operating Guide For additional information on operating this system, consult the DS7400Xi (V er . 4+) User ’s Guide (P/N: 43851) and the front co ver of this Reference Guide.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 27 7 . 4 Fire Safety No fire detection device or system should be considered 100% foolproof. This fire alarm system can provide early warning of a developing fire.
Page 28 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 7. 5 Personal Identification Numbers 7.5.1 General Information A PIN (Personal Identification Number) is the 4- or 6-digit code users must enter at the keypad to gain access to the system.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 29 NOTE: User Number 001 can not be disabled in this manner . 7. 6 The Master Keypad 7.6.1 General Information Y our system may include a Master keypad.
Page 30 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide least two seconds. The system will also drop out of Single Par- tition Mode after 40 seconds without a keypad entry . 7.7 Keypad Error Displays 7.7.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 31 7.8 T esting Y our System 7.8.1 Zone (System W alk) T est The Zone T est is used to confirm that detectors will report alarms to the keypad. A Zone T est works on all zones, except 24-hour zones and fire zones.
Page 32 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 8.0 How to Program the Control Panel 8. 1 Entering the Programmer ’ s Mode T o enter the Programmer ’s Mode, enter the Programmer ’s Code followed by [#] [0].
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 33 9.0 Understanding the Programming Charts The Programming Reference Guide makes use of three types of charts.
Page 34 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.0 Programming 10.1 General Control Programing: Program Address (0000) General Control programming defines the system-wide general operating parameters.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 35 Programming a Zone Programming a Zone is a four step process.
Page 36 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Step 2: Assigning a Zone Function to the Zone In this step, a Zone function is assigned to the Zone.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 37 10.4 Zone Programming: Zone T ype Program Addresses (0415-0538) In Zone Programming, each zone is defined according to its Input (single or multiple zone input, or a DS7465) and its Zone Function or Output function (1-24).
Page 38 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Step 4: Assigning a Partition to the Zone 10.5 Zone Partition Assignment: Program Addresses (0287-0410) In Zone Partition Assignment, each zone is assigned to a partition.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 39 10.6 Zone Bypass Programming: Program Addresses (2721-2724) Zone Bypass programming determines which zone functions can be bypassed. Zone functions that can not be bypassed can not be force armed either .
Page 40 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide *0 - *5 are H ex val ues. They w i l l dis play as A - F at the key pads. 12 Data Dig it P A 2724 123456789 *0 *1 *2 *3 *4 *5 Zon e F unc ti on 25 C an Be B yp ass ed Sel e c t O ptio ns Enter the Data D i git as a: *0 - *5 are He x valu es.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 41 10.7 Output Programming: Program Addresses (2734, 2735, 2736) Output programming defines the event, partition, and type of alarm (burglary or fire) that will trigger each of the three physical outputs on the control panel.
Page 42 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.8 Output Partition Assignment: Program Addresses (2737-2738) In Output Partition Assignment, each On-board output is assigned to a partition. By default, outputs are assigned to all partitions.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 43 10.10 Quick Arm Control Programming: Program Address (3477) Quick Arm Control programming defines which partitions can be quick armed (armed without requiring a PIN to be entered).
Page 44 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.1 1 Keyp ad Assignment Programming: Program Addresses (3131-3138) Keypad Assignment Programming is where you assign the keypad type and the partition to which it belongs.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 45 10.13 Emergency Key Programming: Program Addresses (3147-3148) Emergency Key and Panic Key programming disables or activates these keys (the A, B, and C keys) located on the keypads and/or keyfobs.
Page 46 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.14 Custom Arming Programming: Program Addresses (2725-2728) (Continued) 0 12 3 45 6789 *0 *1 .
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 47 10.15 Force Arming and Ground Fault Detect Programming: Program Address (2732) Force Arming programming defines how many zones may be Force Armed using an Arming sequence followed by the [Bypass] key .
Page 48 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.16 Commercial Fire Mode Programming: Program Address (2733) This section describes how to define the parameters for the Commercial Fire Mode. See Glossary (section 6.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 49 10.17 Open/Close Report Control Programming: Program Address (3149) See Glossary (section 6.
Page 50 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.20 Timer Programming: Program Addresses (4028-4030, 4032-4033) 10.21 AC Fail Report Delay Programming: Program Address (4034) The AC Fail Delay Times are programmed as Hexadecimal values.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 51 10.22 General Authority Programming: Program Address (3421-3424) This allows for a user with a General Authority level to Arm, Disarm and Bypass specified zones.
Page 52 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.24 DS7412 RS232 Interface Control Programming: Program Address (4019) 10.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 53 10.27 Report Programming: Program Addresses (3207-3419) • T o send the User number along with open, close, or partial close reports: place an ‘F’ (*5) in the extended digit.
Page 54 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Report Programming (Continued).
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 55 Report Programming (Continued) 10.28 Phone/DS7416i Routing Control: Program Addresses (3153-3154) If address 3155 is programmed to “Try DS7416i first”, the following addresses can be used to control report routing.
Page 56 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.29 Account Code Programming: Program Addresses (3429-3459) Account Code programming defines the number transmitted to the central station that identifies this panel.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 57 10.30 Phon e Number General Control Programming: Program Address (3155) See Glossary (section 6.
Page 58 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.31.1 Compatible Receivers The following table lists those Digital Alarm Communicator Receivers and Formats that are compatible with the DS7400Xi.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 59 10.33 Pager Delay Time: Program Address (4038) When using the Pager Dialing Format (selected in Addresses 3156 and 3157), you may insert a delay time after the phone number i s dialed and before the reports are sent to the pager system.
Page 60 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.36 Octal Relay Module Output Programming 10.36.1 Follow Action: Program Addresses (2740-2771) T o program an Octal Relay Module for Follow Action, follow the steps below .
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 61 10.36 Octal Relay Module Output Programming (continued) 10.36.2 Follow System Wide Event : Program Addresses (2740-2771) T o program an Octal Relay Module for Follow System Wide Event, follow the steps below .
Page 62 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.36 Octal Relay Module Output Programming (continued) 10.36.3 Follow Function: Program Addresses (2740-2771) T o program an Octal Relay Module for Follow Output Function, follow the step s below .
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 63 10.36 Octal Relay Module Output Programming (continued) 10.36.4 Follow Zone: Program Addresses (2740-2771) T o program an Octal Relay Module for Follow Zone, follow the steps below .
Page 64 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 65 10.36 Octal Relay Module Output Programming (continued) 10.
Page 66 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.37 Output Function Programming: Program Addresses (2772-2843) Output programming allows you to have the Outputs follow status events by partition or system-wide, or follow zone outputs in an Input/ Output Cross Matrix.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 67 10.37.1 Output Function Partition Assignment: Program Addresses (2852-2863) 10.38 Dual Phone Line/Bell Supervision Module Output Programming: Program Address (4021) The Dual Phone Line/Bell Supervision Module is the DS7420i.
Page 68 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.39 Cal l-Out Timer Programming: Program Addresses (4022-4025) This section allows you to define the Hour and Minute for the Communicator T est Report and Remote Programmer Call-Out.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 69 10.41 Alpha Description Programming: Program Addresses (0545-2720, 5001-6920) Alpha Description Programming allows up to 16 characters to be programmed for the description of each partition or zone (e.
Page 70 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.41.1 Alpha Description Programming: A Worksheet.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 71 10.41.1 Alpha Description Programming: A Worksheet (Continued).
Page 72 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.41.1 Alpha Description Programming: A Worksheet (Continued).
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 73 10.41.1 Alpha Description Programming: A Worksheet (Continued).
Page 74 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 10.42 Phone Number Programming: Program Addresses (3159, 3175, 3191) 10.42.1 Phone Number 1 Programming: Program Address (3159) 10.42.2 Phone Number 2 Programming: Program Address (3175) 10.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 75 1 1.0 Installation Guide for UL Listed Systems 1 1.
Page 76 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 1 1.2 Installation Considerations • Failure to install and program the control in accordance with the requirements in this section voids the listing mark of Underwriters Laboratories, Inc.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 77 The controls must be installed in accordance with UL Standards UL681 and UL609 for all grades of service. 1. Report Programming: • Burglar Zone Reports must be programmed for those zones used.
Page 78 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 1. Report Programming: • Burglar Zone Reports must be programmed for those zones used. • Fire Zone Reports must be programmed for those zones used.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 79 12.0 Report Programming 12.1 4/2 Format Suggested V alues Local Program Remo te Pr ogr am A d d.
Page 80 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 12.2 BFSK Format Suggested V alues Loc al P rogra m Remote Pro gram Address Valu e Report S ucce.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 81 12.3 Personal Dialing Format This is a 2 pulse per second (PPS) 0/2 (no account code/2 report event digits) format intended for manual reception, i.
Page 82 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Pager Format (Continued) Suggested V alues Local P rogra m Remo te Program A ddr ess V al ue Rep.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 83 13.0 Report Programming - V alues Sent 13.1 SIA Formats Dat a Digit 2 value SIA Report Explanat.
Page 84 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 13.1 SIA Formats (Continued) FI FK Fire w alk test r eport Fi re w alk te st re st o r al Report.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 85 13.2 CID Formats Report s CID event code CI D data fi eld None 607 Res to r al System walk test.
Page 86 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide 14.0 Multiplex Zone Addressing Guide Before installing a multiplex device, its address and other information must be programmed into the control panel.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 87 15.0 T roubleshooting Guide 15.1 Keypad Problems Entry Error: Please Re-enter will display on keypad. A three beep error tone will sound continuously .
Page 88 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Keypad Problems (Continued) Chime Mode (#7) does not work when a zone is faulted. a ) Not activating for interior zones. b) The keypad is not assigned to the same partition as the zone being activated.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 89 Zone Problems (Continued) Symptom Probable Cause Possible Solution a) The multiplex expansion module is not inst alled properly . b) Multiplex wiring is missing or is not inst alled properly .
Page 90 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide General System Problems (Continued) Symptom Probable Cause Possible Solution Power LED is flashing, keypad displays Control T rouble Press #87. #87 display = Oct.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 91 General System Problems (Continued) Symptom Probable Cause Possible Solution #87 display = Aux Power Fault #87 display = Keypad Fault The auxiliary power output has been shorted.
Page 92 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide General System Problems (Continued) Symptom Probable Cause Possible Solution #87 display = Battery T rouble a) The battery failed a battery test. b) The battery is defective.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 93 Address Description 0000 General Control 0001 Zone Function 1 0002 Zone Function 2 0003 Zone Fu.
Page 94 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Address Description 0189 Zone Number 159 0190 Zone Number 160 0191 Zone Number 161 0192 Zone Num.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 95 Address Description 0392 Zone 21 1 & 212 Partition Assign. 0393 Zone 213 & 214 Partition Assign. 0394 Zone 215 & 216 Partition Assign.
Page 96 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Address Description 2417 Alpha for Zone Number 1 10 2433 Alpha for Zone Number 1 1 1 2449 Alpha .
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 97 Address Description 3209 Zone Function 1 Alarm Report 3210 Zone Function 2 Alarm Report 3 2 11 .
Page 98 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide Address Description 3402 Zone Func. 15 Bypass Restoral 3403 Zone Func. 16 Bypass Restoral 3404 Zone Func. 17 Bypass Restoral 3405 Zone Func. 18 Bypass Restoral 3406 Zone Func.
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 99 Index Symbols 24-Hour Zone ............................................... 19 4/2 Format ..................................................... 79 A AC Failure Report Delay .
P Pager Delay .................................................. 59 Panic Key .............................................. 22, 45 Panic/Duress Output .................................... 21 Partition .................................................
Een belangrijk punt na aankoop van elk apparaat Bosch Appliances DS7447E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bosch Appliances DS7447E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bosch Appliances DS7447E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bosch Appliances DS7447E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bosch Appliances DS7447E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bosch Appliances DS7447E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bosch Appliances DS7447E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bosch Appliances DS7447E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.