Gebruiksaanwijzing /service van het product Solar Water Heater with Electric Backup van de fabrikant Bradford-White Corp
Ga naar pagina of 16
Save this manual for future reference Manual 238-47297-00A SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qua lified servi ce providers) Models Covered by T.
Table of Conte nts Page Service Procedure Introduction ………………………………………………………………………. 2 Tools……………………………………………….
G ENERAL INFORMATION 240 V OLT Ungroun ded Ungroun ded Groundin g BLACK RED GR EEN 240 120 120 Servic e Wire Configuration Single P hase Amps = Watts Exampl e 4500W/240V = 18.75A Volts Watts = A mps x Volts Exam ple 18.75A x 240V = 4500W Ohms = V olts Example (240V ) / 4500W = 12 .
G ENERAL INFORMATION Upper thermostat Surf ac e Mou nt With E CO ( high l imit) 89T S eries Ma nu al ECO ( high limi t) Res et bu tto n T empe ra tur e co ntro l D ial Lowe r th ermos tat Surfac e Mou.
Non- Simultaneous Operation Non -Si mul tane ou s M ode: Allows on ly one heating ele ment to ope rate at a time. For ex ample, whe n the tank is col d, the upper el ement is energi zed firs t, heating th e top of the tan k.
T ROUBLESHOOTING Most com mon cause for improper el ectric backup o peratio n can be linked t o heating el ement failur e. When troubles hooti ng an elect ric backup solar water h eater with th e inci.
SYMPTOM PROBABLE C AUSE CORRECT IVE ACTION No Hot Water 1. No Po wer to he ater . 2. Lo os e wire conne ctio ns . 3 . Ino per ativ e uppe r hea tin g eleme nt. 4. Inop era ti ve u pp er the rm os ta t. 5 . Op en E CO. 6. I nope rat ive so la r contr oll er or con ne ctio n.
SERVICE PROCE DURE RE -I L ine Volta ge & High Limit (E C O) Tes ting WARNING High voltage exposure. U se cau tion when making volt age checks t o avoid perso nal injury. Line Vol ta ge Te stin g Illu str atio n 2 Illustrati on 3 1. Turn “OFF” power to water heat er.
SERVICE PROCEDURE RE- II Heating Element Test ing Step 1. T URN OFF POWER TO WATER HEATER. Step 2. Remove a ccess cove rs from fron t of water heater . Remov e ins ulatio n an d plas tic c over from ther mos t at. Step 3. Disconnec t wi res f rom hea tin g elem ent.
W ARNING High vo ltage exp osure. Use c aution to avoid personal injury durin g this proced ure. Dou ble El eme nt , Non -Si mul tane ou s, S ingl e Ph ase Ope rat ion. Wa ter In T ank Is Co ld W ith Pow er ON. 1. This pro cedure assumes line voltage , ECO and elemen ts ar e in w orki ng or der.
Do uble Eleme nt , No n-S imu ltan eou s, S ing le P hase Ope ra tion (c ontin ued ). Not En ough Ho t Water (c ontinue d). 7. Chec k voltage acros s terminal L4 of up per therm osta t and terminal 1 of lower thermo stat (see il lustration 9 ). A) Rated volt age NOT pres ent, - check wire c onnection b etween t hermostat s.
SERV ICE PROCEDURE RE-I V Thermostat R emoval and Re placement Front View Ther mos tat M ounti ng Therm ostat Rem oval 1. Tu rn po wer “O FF” To water heater . 2 . Remove acces s cover and insulat ion . 3. Remove plast ic therm ostat prot ector from thermost at.
SERVICE P ROCEDURE RE- V H eating E lement Removal and Replacement Hea ting Element R emoval 1 . Turn power “OFF” To wat er heat er. 2 . Turn o ff cold water suppl y to he ater. Conn ect hos e to drain spigot of water heat er and ro ute to an open d rain.
Page 1 4 S tep 1 . Turn po wer “OFF ” to wa ter heater . Step 2 . Tur n off cold w ater su pply to hea ter. C onnect ho se to dra in spigot of water hea ter and r oute to a n open dr ain. Ope n a nearb y hot water faucet t o vent he ater for dr aining .
Page 1 5 G eneric Part s List 1. Inte grate d Mixin g Device 2. Hex H ead Ano de 3. Junction Box Cover 4. Cover Co nduit/ Gro und 5. ¾" Plug 6. Hot Wate r Outlet/A node 7. Cold Wa te r Inlet Dip Tube 8. Access Cove r 9. The rmos tat P rot ector (L arg e) 10.
Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com.
Een belangrijk punt na aankoop van elk apparaat Bradford-White Corp Solar Water Heater with Electric Backup (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bradford-White Corp Solar Water Heater with Electric Backup heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bradford-White Corp Solar Water Heater with Electric Backup vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bradford-White Corp Solar Water Heater with Electric Backup leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bradford-White Corp Solar Water Heater with Electric Backup krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bradford-White Corp Solar Water Heater with Electric Backup bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bradford-White Corp Solar Water Heater with Electric Backup kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bradford-White Corp Solar Water Heater with Electric Backup . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.