F or m No . PD S 502A. 24.1 HORIZONT AL INDOOR SINGLE P A CKA GE COOLING UNITS Single P ac kage Coo ling Un its F eaturing: • compac t design • flexibili ty • eas y main tena nce • high qu ali.
2 T ABLE OF CONTENTS Pa g e F eatures/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Model Nu mber Nome nclature . . . . . . . . . . . . . . . . . . . . . . . . . 2 ARI Capacit y Ratings . . . . . . . . . . . . . . . . .
3 PHYSICAL D A T A LEGEND *Shipping weights include base unit plus packaging. † If components are to be split, additional refrigerant will be needed.
4 FIELD-INST ALLED A CCESSORIES Thermo stat and Subbase — Attract i v e wall-mo unted 24-v access or y provi des pr eci se te mperat ure c ontr ol. Auto matic and Manu al changeo ver mo dels av ailab le. A thermostat s ubbase is av ailab le that works w ith Cycle-L OC ™ circuitr y .
5 B ASE UNI T DIMENSION S DIMENSIONS (ft-in.) UNIT 502A ABCDE 024 2-5 2-1 5 / 8 1- 5 3 / 4 1-2 1-1 036 2-4 3 / 4 2-2 1- 5 3 / 4 1-2 1-1 048 2-5 2-3 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 060 2-4 3 / 4 2-2 3 /.
6 SELECTION PROCEDURE (with e xample) I DETERMINE COO LING REQUIREMENTS A T DESIGN CONDITIONS. Given: Gross C ooling Capacity Required (TC) . . . . . . . . . . . . . . . . . . . . . . . . . 39,00 0 Btuh Sensib le Heat Capaci ty (SHC) . . . . . . . . .
7 PERFORMANCE D A T A (cont) GROSS COOLING CAP A CITIES (cont) LEGEND NO TES: 1. Perf or m ance based on nomin al conden ser airflow l isted in physical da ta table on page 3 . 2. SHC is ba sed on 80 F db te mperature of air e nteri ng the co il. Below 80 F db, subtract (corr factor x cfm) from SHC.
8 PERFORMANCE D A T A (cont) BEL T DRIVE EV APORA T OR F AN PERFORMANCE (Spec ial Or der Only , Pricing an d or dering on related pri ce pages.) LEGEND NO TE: Pulley setting must be adjusted to limit cfm to 450 cfm/ton maximum. Unit operation bey ond that limit may result in blo w-off and condensate problems .
9 CONTR OLS OPERA TING SEQUENCE Cooling 1. The r mosta t call s f or co oling . a. Indoor (e v aporator) f an rela y is energiz ed and starts e vap orato r f an. b . Compr essor contact or is energiz ed to star t compre ssor and conde nser fa n (up to a 5-min ute dela y on single- phase u nits).
10 ELECTRICAL D A T A (cont) ELECTRIC HEA TER ST A TIC PRESSURE DR O P (in. wg) NO TE: Abov e el ectric he aters are not UL or CSA listed f or use with optional hi gh-static ev apora tor-f an motor (048, 060 units only).
11 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Disc.
12 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Disc.
13 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator BKR W/A T — Breaks wit h Amp T urns C — Contactor Compressor CC — Cooling Com pensator CLO — Comp ressor L ocko.
14 TYPICAL PIPING AND WIRING APPLICA TION D A T A OUTDOOR-AIR TEMPERA T URE OPERA TING LIMIT S (F) Field Splitting Ins tructions — If c omp onen ts ar e s plit , ma xi- mum length of ref rigerant tubing to be us ed is 50 ft, as suming compon ents are ins talled in same hor iz ontal pl ane.
15 GUIDE S PECIFICA TIONS INDOOR P A CKA GED UNIT HV AC GUIDE SPECIFICA TIONS — SECTION 157 87 SIZE RANGE: 2 T O 5 T ONS, NOMINAL BR Y ANT MODEL NUMBER: 502A PA R T 1 — GENERAL 1.01 SYSTEM DESCRIPTION Indoor mo unted, electrically c ontrolled pac kaged horizon- tal coo ling unit uti lizing a her metic typ e scroll compre ssor .
Copyright 2001 Bryant Heating & Cooling Systems Printed in U.S . A. 1-01 Catalog No. 5250-200 SPECIFICATIONS SUBJE CT TO CHANGE WITHOUT NOTICE UNIT MUST BE INST ALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS GUIDE SPECIFICA TIONS (cont) 3.
Een belangrijk punt na aankoop van elk apparaat Bryant 502A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bryant 502A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bryant 502A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bryant 502A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bryant 502A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bryant 502A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bryant 502A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bryant 502A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.