NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation. This symbol → indicates a change since the last issue.
I. INSPECT PACKAGE AND CHECK EQUIPMENT Inspect contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incom- plete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3.
VI. INSTALL DRAIN LINE 1. Use 1/2- or 5/8-in. vinyl tubing (field supplied) to connect drain on bottom of humidifier housing to an open drain. 2. Use supplied worm clamp to hold drain tubing in position over drain fitting outlet. CAUTION: Unit may leak if drain tubing is misapplied.
II. SELECT LOCATION (SEE FIG. 5.) Humidifier must be installed on supply plenum only. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
INSTALLATION OF HUMBBSFP1016-A-- FAN POWERED HUMIDIFIER Bryant’s HUMBBSFP1016-A-- fan powered humidifier can only be installed on the supply plenum of a forced-air system. This unit requires an external 115-vac (fused) plug-in receptacle near the equipment for proper operation.
IV. MOUNT THE HUMIDIFIER 1. Attach foam tape to back of mounting flange (exclude the off-set edge). 2. Hook off-set edge over opening cut in plenum. 3. Place humidifier in plenum aligning screw holes with flange. 4. Align, level, and tighten all screws for air tight seal.
INSTALLATION OF HUMBBSBP2017-A-- BYPASS HUMIDIFIER Bryant’s HUMBBSBP2017-A-- bypass humidifier can be installed on either the supply or return plenum of a forced air system. This unit requires an external bypass duct between the supply- and return-air ductwork.
5. Attach transfer tube to solenoid valve and insert free end into inlet fitting on top of unit housing. 6. Attach bridge rectifier to solenoid valve. 7. Insert sheet metal screws into lower holes in plenum, pre-drilled using template. 8. Tighten screws until heads protrude approximately 3/16-in.
II. SELECT LOCATION (SEE FIG. 14.) Humidifier may be installed on either supply or return plenum. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING 1. Mount humidistat on inside wall or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TAT on page 10. NOTE: Wiring must comply with national electrical code and any local codes or ordinances that may apply.
II. DUCT MOUNTING (LOW VOLTAGE) 1. Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in.
V. OPERATION When relative humidity falls to humidistat set point, the humidistat switch makes contact and starts humidifier. In some central unit humidifier systems, furnace fan must be operating before humidi- fier will start. An increase in relative humidity above set point will stop humidifier.
Een belangrijk punt na aankoop van elk apparaat Bryant HUM-56-1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bryant HUM-56-1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bryant HUM-56-1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bryant HUM-56-1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bryant HUM-56-1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bryant HUM-56-1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bryant HUM-56-1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bryant HUM-56-1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.