BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .bunnomatic.com OPERA TING & SER VICE MANUAL CEZ, CEZF , CDBC, CDBCF Airpot, Thermal Carafe & Thermal Ser ver Brewers 29253.
Page 2 INTRODUCTION This equipment will automatically brew a half-gallon batch of coffee into an awaiting server at the press of a button. A hot water faucet may be included for allied beverage use. Most functions of the brewer are digitally controlled.
Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition.
Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.
Page 5 OPERA TING CONTROLS Model CEZ-APS/TS/TSR ON/OFF SWITCH Placing the "ON/OFF" switch in the "ON" upper position enables the brew circuit, and energizes the tank refill circuit. Placing the switch in the "OFF" lower position stops tank refilling and brewing.
Page 6 INITIAL SET -UP 1. Insert an empty funnel into the funnel rails. 2. Place an empty server under the funnel. 3. Connect the brewer to the power source. 4. Model CDBC-APS/TC/TS/TSR – Press the "ON/OFF" switch (indicator glowing). Model CEZ-APS/TS/TSR – Place the "ON/OFF" switch in the "ON" upper position.
Page 7 CEZ-APS/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS.
Page 8 CDBC-APS/TC/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS Setting Brew Temperature The brewer is factory set to brew at 200 ° F(95 ° C). To change this setting, press and hold the "HIDDEN" switch beneath the "®".
Page 9 CDBC-APS/TC/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS (cont) W ater Sensing Threshold Adjustment Procedure 1. Make sure the tank is full of water to be used for calibration. The water must be in contact with the refill probe. 2. Unplug the brewer from the power source, then press and hold the BREW button while power is reapplied.
Page 10 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Page 11 Will not fill or refill Fill or refill does not shut "OFF" (ON/OFF Switch "ON") PROBABLE CAUSE REMEDY PROBLEM 1. Power off to brewer (CDBC-APS/ TC/TS/TSR & CEZ-APS/TS/TSR) 2. Water shut off (CDBC-APS/TC/ TS/TSR & CEZ-APS/TS/TSR) 3.
Page 12 TROUBLESHOOTING (cont.) Fill or refill does not shut "OFF" (ON/ OFF Switch "ON") (cont) Fill or refill does not shut "OFF" (ON/ OFF Switch "OFF") PROBABLE CAUSE REMEDY PROBLEM 2a. Water Level Probe Sensing System (CDBC-APS/TS/TSR) 2b.
Page 13 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY HEATING CIRCUIT 1. Display flashing (CDBC-APS/TC/ TS/TSR) or ready light flashing (CEZ-APS/TS/TSR) 2. Water not touching temperature probe 3a. Dry Plug In Probe Sensing Sys- tem (CDBC-APS/TC/TS/TSR) 3b.
Page 14 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper temperature (cont.) IMPORTANT: Make sure no tem- perature tests are taken before the ready light is "ON". Tank tempera- ture must be stabilized before read- ings are taken.
Page 15 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming (cont.) Brewer is making unusual noises 2a. Temperature Probe (CDBC-APS/ TC/TS/TSR) 2b. Temperature Probe (CEZ-APS/ TS/TSR) 3. Control Board (CDBC & CEZ) 1.
Page 16 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT Brew cycle will not start 1. Display flashing (CDBC-APS/TC/ TS/TSR) or ready light flashing (CEZ-APS/TS/TSR) 2. No water 3. No power or incorrect voltage to the brewer 4. ON/OFF switch not in the "ON" position 5.
Page 17 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) If the start switch (CEZ-APS/TS/ TSR) or switch panel (CDBC-APS/ TC/TS/TSR) is operating properly, proceed as follows. Attach a volt- meter to the terminals of the dis- pense valve solenoid.
Page 18 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Dripping from sprayhead Weak beverage 1. Lime build up 2. Dispense valve 1. Sprayhead 2. Water temperature 3. Filter type 4. Coffee grind 5. Funnel loading Inspect the tank assembly for ex- cessive lime deposits.
Page 19 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Dry coffee grounds remain in the funnel 1. Sprayhead 2. Funnel loading Make sure sprayhead is present and holes are clear and unobstructed. There should be separate streams of water coming out of each hole in the sprayhead.
Page 20 DIAGNOSTICS Intermittent flashing of the READY indicator (Model CEZ) or the bank of temperature indicators (Model CDBC) indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault.
Page 21 BUNN M AN UFA CTU RE D B Y BU NN-O -M AT IC C OR POR ATIO N SPR INGF IE LD, I LLINO IS , U.S .A . M OD EL S/ N V OLTS A .C. AMP W AT TS PH ASE W IRE HE RTZ COV ERE D UN DER O NE O R MORE OF TH.
Page 22 BUNN M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R IN G F I E L D , I L L IN O IS 894 589.253 c128.894 588.855 129.173 588.694 129.517 588.893 ch129.217 588.8S A M O D E L52 613.249 -5 ch129.217 580.
Page 23.
Page 24.
Page 25 BUNN MANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A. MODEL S/N VOLTS A.C. AMP WATTS PHASE WIRE HERTZ COVERED UNDE R ONE OR MOREOF THE FOLLOWING PATENTS : ONE OR M ORE OT.
Page 26 BUNN MANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A. MODEL S/N VOLTS A.C. AMP WATTS PHASE WIRE HERTZ COVERED UNDER ONE OR MOREOF THE FOLLOWING PATENTS : ONE OR MORE OTHE.
Page 27 BUNN M A NU FA CT URE D BY B UNN -O -M AT IC C O R PO R A T ION SP RIN G FIELD , IL L IN OIS , U .S .A. MO DEL S /N V OL T S A.C . AM P WA TT S P HA SE W IR E HE RT Z CO V ERE D U N DE R O NE .
Page 28 BUNN M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R I N G F I E L D , I L L I N O I S , U . S . A . M O D E L S / N V O L T S A .
Page 29 Location: The tank heater is located inside the tank and secured to the tank bottom. Test Procedures: 1. Disconnect the brewer from the power supply. 2. With a voltmeter, check the voltage across the white or red wire from the terminal block and the black wire from the control board.
Page 30 P1856 SERVICE (cont.) TANK HEATER (Cont.) BLK to Control Board WHI or RED to Terminal Block FIG. 14 TANK HEATER WIRING 17. Install tank assembly onto mounting brackets and secure in place with four #8-32 nuts. 18. Install tank lid and secure in place with eight #8-32 nuts.
Page 31 T RM 2 J1 J2 J3 J4 J5 J6 J7 TR M1 CAUTION : WARMERS AND SURFACES ARE HOT SERVICE (cont.) REFILL VALVE Location: The refill valve is located inside the trunk on the lower center part of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source.
Page 32 SCHEMA TIC WIRING DIAGRAM CDBC-APS/TS/TSR 29253 111103 EARL Y MODELS SOL 29257.0000B 12/99 ©1998 BUNN-O-MATIC CORPORATION TANK HEATER L1 GRN GRN RED-14 (MODEL 35) WHI-14 (MODELS 15 & 20) .
Page 33 SCHEMA TIC WIRING DIAGRAM CEZ-APS/TS/TSR WHI 29341.0000B 6/99 ©1998 BUNN-O-MATIC CORPORATION WHI WHI BREW SWITCH TANK HEATER GRN RED-14 (MODEL 35) WHI-14 (MODELS 15 & 20) N L2 BLU-14 "KEEP WARM" HEATER WHI SOL REFILL SOL DISPENSE TRM-1 TRM-2 J7-1 J7-2 J1-1 J1-8 J5-1 J5-6 C O N T R O L B O A R D COM N.
Page 34 LA TE MODELS 29253 021604 SOL SCHEMATIC WIRING DIAGRAM CDBC 15, 20 & 35 APS/TC/TS 29257.0001D 02/04 ©1999 BUNN-O-MATIC CORPORATION TANK HEATER L1 GRN RED-14 (MODEL 35) WHI-14 (MODELS 15 &.
Een belangrijk punt na aankoop van elk apparaat Bunn CDBCF Airpot (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bunn CDBCF Airpot heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bunn CDBCF Airpot vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bunn CDBCF Airpot leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bunn CDBCF Airpot krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bunn CDBCF Airpot bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bunn CDBCF Airpot kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bunn CDBCF Airpot . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.