OPERA TING & SER VICE MANU AL B UNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 10690.
Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for either pour-over or automatic brewing. The automatic version may include a hot water faucet for allied beverage use.
Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition.
Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.
Page 5 PLUMBING REQUIREMENTS (cont.) SECOND TYPE MODELS W/FAUCET THIRD TYPE MODELS W/FAUCET Models CWTF-APS, CWTF-TS CWTF-TSR: 1. Flush the water line and securely attach it to the flare fitting on the strainer or tee. 2. Turn on the water supply. 3. Place an empty vessel beneath the faucet and lift the handle until water is dispensed.
Page 6 INITIAL SET -UP CAUTION - The brewer must be disconnected from the power source throughout the Initial Set-up , except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. 2. Place an empty dispenser under the funnel.
Page 7 10690 062300 ADJUSTING BREW VOLUMES CAUTION - Disconnect the power source fr om the brewer prior to the removal of any panel for the replacement or adjustment of any component.
Page 8 COFFEE BREWING 1. Insert a BUNN ® filter into the funnel. 2. Pour the fresh coffee into the filter and level the bed of grounds by gently shaking. 3. Slide the funnel into the funnel rails. 4. Place an empty dispenser beneath the funnel. 5. Operate the brewer as directed: 5A.
Page 9 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Page 10 TROUBLESHOOTING (cont.) PROBLEM Brew cycle will not start (cont.) (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR &CWTF- TSR) Water is not hot PROBABLE CAUSE REMEDY 3. ON/OFF Switch 4. Start Switch 5. Timer 6. Solenoid Valve 7. Water strainer/flow control (.
Page 11 TROUBLESHOOTING (cont.) PROBLEM Inconsistent beverage level in dis- penser Consistently low beverage level in the dispenser (CWT-APS, CWTF- APS, CWT-TS, CWTF-TS, CWT- TSR & CWTF-TSR) Spitting or excessive steaming PROBABLE CAUSE 1. Strainer /flow control (.
Page 12 TROUBLESHOOTING (cont.) PROBLEM Spitting or excessive steaming (cont.) Dripping from sprayhead Water flows into tank continuously (ON/OFF Switch "ON") Water flows into tank continuously (ON/OFF Switch "OFF") Beverage overflows dispenser PROBABLE CAUSE 2.
Page 13 TROUBLESHOOTING (cont.) PROBLEM Weak beverage Dry coffee grounds remain in the funnel Brewer is making unusal noises (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR, CWTF-TSR) PROBABLE CAUSE 1. Filter Type 2. Coffee Grind 3. Sprayhead 4. Funnel Loading 5.
Page 14 TROUBLESHOOTING (cont.) PROBLEM Brewer is making unusal noises (cont.)(CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR, CWTF-TSR) Brewer is making unusal noises (CW) PROBABLE CAUSE 4. Tank Heater 1. Tank Heater REMEDY Remove and clean lime off the tank heater.
Page 15 CWT-TSR SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary.
Page 16 SERVICE (cont.) CONTROL THERMOSTAT LATE MODELS Location: Early Models: The control thermostat is mounted on a bracket inside the hood on the right side just in front of the tank lid. Late Models: The control thermostat is located inside the trunk on the left side of the component bracket.
Page 17 SERVICE (cont.) P1129 LIMIT THERMOSTAT Location: The limit thermostat is located inside the rear of the hood on the tank lid. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the blue and black wires from the limit thermostat.
Page 18 SERVICE (cont.) ON/OFF SWITCH Location: The ON/OFF switch is located on the left front of the hood. Test Procedure: 1. Disconnect the brewer from the power source. 2. Viewing the switch from the back remove the white wire from the upper terminal and the black wire from the center terminal.
Page 19 SERVICE (cont.) SOLENOID VALVE P1127.40 Location: The solenoid valve is located inside the trunk on the center lower part of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the white and black wires from the solenoid valve.
Page 20 SERVICE (cont.) START SWITCH P0150.50 Location: The start switch is located in the front of the hood just to the right of center. Test Procedure: 1. Disconnect the brewer from the power supply. 2. Disconnect the blue wire from the top switch terminal and the white/red wire from the bottom switch terminal.
Page 21 TANK HEATER P1127.40 Location: The tank heater is located inside the tank and secured to the tank lid. Test Procedures: 1. Disconnect the brewer from the power supply.
Page 22 SERVICE (cont.) TANK HEATER (Cont.) P1134.65 10690 062300 10. Install new tank heater with gaskets on the tank lid and secure with two hex nuts. 11. Install tank lid with limit thermostat, sprayhead tube, tank heater, coil assembly (brewers with faucet) and control thermostat with bracket (early brewers only) using eight #8-32 hex nut.
Page 23 SERVICE (cont.) TANK HEATER SWITCH P1127.40 Location: The tank heater switch is located on the rear of the brewer on the upper left side of the trunk. Test Procedure: 1. Disconnect the brewer from the power source. 2. Disconnect the black wire from the limit thermo- stat.
Page 24 SERVICE (cont.) P1135 10690 062300 TANK HEATER SWITCH (cont.) 13. Remove the plastic facenut, hex facenut and the switch indicator/guard bracket that secures tank heater switch to the rear of the brewer.
Page 25 TIMER(Early Models) P1127.40 Location: The timer is located inside the front of the trunk on the top of component bracket. Test Procedure. 1. Disconnect the brewer from the power source. 2. Disconnect the polarized, three pin connector from the brewer wiring harness and rotate the brew timer dial fully counterclockwise.
Page 26 SERVICE (cont.) TIMER (cont.) P1136 10690 062300 If voltage is present as described, the brew timer is operating properly. Reset the timer dial as required, to obtain the desired brew volume. If voltage is not present as described, replace the timer.
Page 27 DIGITAL BREW TIMER (Late Models) P1127.40 FIG. 18 DIGITAL BREW TIMER Location: The timer is located inside the front of the trunk on the top of the component bracket. Test Procedure. NOTE: Do not remove or install wires while timer board is installed.
Page 28 BLU/BLK wire from TL5 to P1 WHI/GRN wire from TL4 to (WHI) Solenoid WHI/BLU wire from TL3 to (BLK) Solenoid WHI wire from TL2 to P2 BLK wire from TL1 to P3 FIG. 19 DIGIT AL TIMER WIRING P2037 SERVICE (cont.) DIGITAL BREW TIMER (Late Models)(cont.
Page 29 10690 081100.
Page 30 10690 081100.
Page 31 10690 081100.
Page 32 10690 081100.
Page 33 10690 081100.
Een belangrijk punt na aankoop van elk apparaat Bunn CWT-TSR (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bunn CWT-TSR heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bunn CWT-TSR vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bunn CWT-TSR leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bunn CWT-TSR krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bunn CWT-TSR bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bunn CWT-TSR kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bunn CWT-TSR . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.