FACTORY AUTHORIZED SERVICE COFFEE BREWERS MODELS F-35, F-20, F-15 MODELS ABOVE SERIAL NUMBER* F·35 57581 F·20 30872 F·15 30179 LISTED r'pproved bYe'"'' f(J:666L ~ ~ ~ ~:~~ .
E l E C T R I C I AN'S INS TAL lA T ION INS T R U C T ION S MODEL f·35 MODELS f·15 & f·20 ELECTRICAL REQUIREMENTS: 1 • MODELS F35 120/240 volts A.C., 60 hertz, 3 wire, single phase. 20 amp. wiring required. • MODEL F20 120 volts A.C., 60 hertz, 2 wire, single phase.
/ -t 1. 2. 3. 4. 5. INITIAL OPERATION INSTRUCTIONS IMPORTANT: • Brewer must be level or slightly lower f'n front to siphon properly. • Electrician's and Plumber's instructions are provided on page 2. These instructions should be carefully followed before proceeding with initial operation instructions.
FACTORY AUTHORIZED SERVICE TROUBLE SHOOTING GUIDE MODELS F·35, F·20, F·15 SYMPTOM POSSIBLE CAUSE WHAT TO CHECK REMEDY Cannot Start 1. No Water. 1. Incoming water lines 1. Be sure water shut Brew Cycle and water shut off valve. off valve is open. 2.
FACTORY AUTHORIZED SERVICE '0551 BLE CAUSE WHAT TO CHECK REMEDY NO HOT WATER 1. Tank heater 2. Limit Thermostat or Control Thermostat. 1. Voltage at tank heater terminals with control thermostat knob in the fully clockwise position. Voltage should be: Model F35 240 volts A.
, SYMPTOM POSSIBLE CAUSE WHAT TO CHECK REMEDY WATER KEEPS 1. Timer. 1. Paddle arm on timer. 1. If paddle arm on timer RUNNING Check to see if slips or doesn't move, (BREWER WILL paddle arm on timer replace timer. SHUT OFF slowly moves around ELECTRICALLY).
r , SYMPTOM POSSIBLE CAUSE WHAT TO CHECK REMEDY DRY COFFEE 1. Fi Iters. 1. Check if Bunn Filters 1. Bunn Filters should REMAINING IN are being used. always be used. BREW FUNNEL 2. Not siphoning 2. Refer to "Dripping" 2. Refer to "Dripping" AFTER BREW CYCLE HAS properly.
COMPONENT' REPLACEMENT INSTRUCTIONS CAUTION: DISCONNECT COFFEE BREWER FROM POWER SOURCE PRIOR TO REMOVING ANY COM. PONENTS. Access to electrical components is gained by removing front access panel. CONTROL THERMOSTAT 1. To gain access, remove top lid via 4 screws and remove front panel.
SOLENOID ~, II SOLENOID VALVE VALVE 1. Shut off water supply to brewer. -. I P~3 ~~ 2. To gain access INCOMING remove front panel. WATER 3. Disconnect leads (A) from solenoid ter- minals. 4. Disconnect f I are nuts (B&C) from ,~ • l ,--. II It' "- I I solenoid valve.
SCHEMATIC WIRING DIAGRAM F15 & 20 N WHI ~~ WHI P2 GREEN =!- F151320W F20 1800W f--'VVV' . TANK HEATER 100W --{}-'VV'. TOP REAR WARMER 100W WHI -u-~ TOP FRONT WARMER 130W ~ LOWER WARMER P1 <, BLU BLK BAN P3 BLU P1 BLU 1..L1 BLU lit .
REPLACEMENt PARTS 01637.0000 Cordset, 5',16/3, HSJO, NEMA 5-15P (model 15) 00658.0000 Decal, Decanter & Funnel Safety 00831.0000 Decal, Electrical 01188.0000 Deliming Spring 20528.1175 Flow Regulator (.175) 00445.0000 Flow Regulator Adapter 20526.
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY _ Bunn-O-Matic Corp. (UBunn") warrants the equipment manufactured by it to be commercially free from defects in material ""- and workmanship existing atthe time of manufacture and appearing within one year from the date of installation.
Een belangrijk punt na aankoop van elk apparaat Bunn F-20 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bunn F-20 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bunn F-20 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bunn F-20 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bunn F-20 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bunn F-20 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bunn F-20 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bunn F-20 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.