Gebruiksaanwijzing /service van het product AL SL van de fabrikant Burnham
Ga naar pagina of 24
1 INST ALLA TION, OPERA TING AND SER VICE INSTRUCTIONS FOR Alliance SL ™ Indirect - Fired W ater Heater For service or repairs to the water heater , call your heating contractor . When seeking informa- tion on the water heater , provide Model Number and Serial Number as shown on Rating Label.
2 PLEASE READ INSTRUCTIONS CAREFULL Y BEFORE INST ALLING W A TER HEA TER U.S Boiler Company , Inc. – Burnham Hydronics (herein called the Company) intends that this Alliance SL™ Indirect-Fired W ater Heater be used as a separate zone to a heating system boiler .
3 INDEX General Information ..................................................................................................................... 2 Specications & Ratings .........................................................................
4 A. INSPECTING AND PREP ARING THE W A TER HEA TER q AL27SL thru AL70SL - Remove the cardboard box, which comes packaged with the heater . It should contain the following: TPI thermostat, T&P valve and a “T ee”, foamed lid and screws. q AL1 19SL - Remove the cardboard boxes, which come packaged with the heater .
5 valve must be marked with maximum set pressure not to exceed the marked maximum allowable working pressure of the water heater (150psi). Install the valve into the opening provided and marked for th.
6 q Do not apply heat directly to the cold-water inlet as it is made of plastic and will melt. G. BOILER SUPPL Y CONNECTIONS q W ARNING: Boiler temperature must be controlled by the boiler high limit not to exceed 200°. Failure to do so will create a hazardous installation and void the applicable limited warranties.
7 q Run all 24V AC wiring thru the square notch on bottom of TPI case. (See TPI Diagram 3) q Incoming 24V AC power must be connected to 24V AC connectors on the bottom right corner of TPI control.
8 q Do not apply heat to cold inlet. q If there is a check valve (sometimes in water meter), backow preventer or pressure-reducing valve, install an adequate size expansion tank. G. FILLING THE HEA TER q Completely ll heater .
9 W A TER TEMPERA TURE CONTROLS A periodic inspection of the operating controls, heat exchanger and wiring should be made by qualied ser - vice personnel. T emperature of the water should be tested periodically at the faucet to be sure thermostat is working properly .
10 TPI CONTROL - DIAGRAM 1 Indicating Light T emperature Adjust Differential Adjust TPI CONTROL - DIAGRAM 2 Screw A.
1 1 TPI CONTROL - DIAGRAM 3 Outgoing 24V wires to relay or zone valve Incoming 24V power connection Outgoing 1 10V wires to circulator Chase Nipple Conduit Incoming 24V power connections NOTE: Use pro.
12 FIGURE 1 - Installation Using Zone V alves Installation Diagram Using Zone V alves FIGURE 2 - Installation Using Circulator Installation Diagram Using Separate Circulator.
13 FIGURE 3 - Coil Detail & T ightening Sequence Bolt Steel W asher Coil Plate Plastic O-Ring Housing T ank Flange ‘L ’ Nut Small outside O-ring Large inside O-ring Proper T ightening Sequence for T op Mount Coil CAUTION: Does not require excessive force to seal properly .
14 Low V oltage 120 V olts L1 Hot 120 V olts L2 Neutral Circula tor 24v T emperature Differential Pump/TT 24v LED flashing green = calling for heat solid green = at temperature red = error 20° 15° 1.
15 Zone V alve Wiring Diagrams Wiring for 3 W ire Zone V alve L o w V oltage 120 V olts 120v 24v B oiler C onnec tions T 1 T 2 3 H ot N eutr al Z one V alv e 120v 24v T o B oiler C onnec tions /C ir c.
16 Switching relay Wiring Diagrams Switching Relay SR-502 or SR-503 Switching Relay R8845U or SR 501.
17 Switching relay Wiring Diagrams (con’t) Switching Relay SR-504 with Priority Option L o w V oltage 120 V olts FUSE 1 AMP C OM / 24 V A C FOUR Z ONE SWIT CHING REL A Y WITH OPTIONAL PRIORIT Y Z ON.
18 HOW T O OBT AIN SER VICE ASSIST ANCE U.S. Boiler Company , Inc. – Burnham Hydronics does not have a service department or personnel to ser- vice your heater in the eld.
19 Alliance SL™ Indirect-Fired W ater Heater 10/2/1 LIMITED W ARRANTY T en Y ear Limited T ank Replacement W arranty T wo Y ear Limited T ank Replacement Labor Allowance One Y ear Limited Parts W arranty U.
20 ONE (1) YEAR LIMITED P ARTS W ARRANTY DURA TION: The warranty is effective for one (1) year beginning with the date of original purchase. This warranty shall begin from the date of manufacture as indicated by the serial number .
21 MODEL & SERIAL NUMBER INFORMA TION The following information should be noted At time of installation and retained for Future reference. Model No. Serial No. Date Installed Dealer ’s Name Address City State Zip U.S. Boiler Company , Inc., – P .
22 NOTES.
23 NOTES.
24 Optional Lifetime W arranty Registration Card A vailable to Residential, Single Family Homes Only Y es, I wish to purchase the Optional Lifetime W arranty! DA TE ___________________________________.
Een belangrijk punt na aankoop van elk apparaat Burnham AL SL (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Burnham AL SL heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Burnham AL SL vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Burnham AL SL leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Burnham AL SL krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Burnham AL SL bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Burnham AL SL kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Burnham AL SL . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.