COAXIAL MEDIA INTERFACE MODULE (THN-MIM) INSTALLATION GUIDE The Complete Networking Solution™ CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505.
NOTICE i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
NOTICE ii FCC NOTICE This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CONTENTS iii TABLE OF CONTENTS CHAPTER 1 INTRODUCTION 1.1 INTRODUCTION ........................................................................ 1-1 1.2 USING THIS MANUAL .............................................................. 1-2 1.3 SPECIFICATIONS .
CONTENTS iv.
INTRODUCTION Page 1-1 CHAPTER 1 INTRODUCTION 1.1 INTRODUCTION Cabletron Systems Coaxial Media Interface Module (THN-MIM) provides 12 Ethernet/lEEE 802.3 coaxial cable connectors per module. When used with the MMAC-8 ™ enclosure, up to 84 coaxial segments can be connected to one MMAC ™ .
INTRODUCTION Page 1-2 can be connected directly to the module. Each of these segments supports one device. The entire THN-MIM or each port on the MIM can be controlled via the IRM in your MMAC.
INTRODUCTION Page 1-3 NOTE: Cabletron Systems reserves the right to change these specifications at any time without notice. BNC INTERFACE (Ports 1-12) Type: BNC receptacle, with gold center contact, for use with BNC type plugs and RG-58 thin-net cable.
INTRODUCTION Page 1-4 SAFETY WARNING: It is the responsibility of the person who sells the system of which the THN-MIM will be a part, to ensure that the total system meets allowed limits of conducted and radiated emissions. Designed in accordance with UL478, UL910, NEC 725-2(b), CSA, IEC, TUV, VDE class A.
INSTALLATION Page 2-1 CHAPTER 2 INST ALLA TION 2.1 INTRODUCTION The Cabletron Systems THN-MIM is designed for quick and easy installation into an MMAC. No special skills or tools are required to install this module. 2.2 NETWORK DESIGN GUIDELINES The following network design guidelines must be followed when connecting segments to the THN-MIM.
INSTALLATION Page 2-2 Since the ports on the module are internally terminated, the end of the segment that will be connected to the module will not be a tee connector or terminator.
INSTALLATION Page 2-3 • The THN-MIM7593 does not report false collisions to the IRM. However, if a non-Cabletron Systems Ethernet device is connected to the segment, it is possible for false collisions to be generated. Non-Cabletron System devices should be thoroughly tested before using them with the THN-MIM7593.
INSTALLATION Page 2-4 2.3 INSTALLATION Install the THN-MIM into the MMAC as follows: CAUTION: Observe all electrostatic precautions when handling the THN-MIM. Static discharges will damage the module. 1. Remove the unit from the shipping box. 2. Slide the two foam end caps off the unit.
TESTING AND LANVIEW Page 3-1 CHAPTER 3 TESTING AND LANVIEW 3.1 INTRODUCTION This section lists procedures to ensure that the segments connected to the Cabletron Systems THN-MIM are operating properly. A description of LANVIEW LEDs and their function in troubleshooting physical layer network problems are also provided.
TESTING AND LANVIEW Page 3-2 At least 100 packets should be sent and received with no errors. The packets will be received from and sent back to the LAN-MD acting as the SERVER . When the applicable segment(s) connected to the THN-MIM have successfully completed these tests, the segments are ready for normal operation.
Een belangrijk punt na aankoop van elk apparaat Cabletron Systems THN-MIM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Cabletron Systems THN-MIM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Cabletron Systems THN-MIM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Cabletron Systems THN-MIM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Cabletron Systems THN-MIM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Cabletron Systems THN-MIM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Cabletron Systems THN-MIM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Cabletron Systems THN-MIM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.