User's Guide


CASIO ELECTRONICS CO., LTD. Unit 6, 1000 North Circular Road, London NW2 7JD, U.K.

..... 2

Be sure to read the following safety precautions before using this calculator. Keep this manual handy for later ref- erence.
This symbol is used to indicate information that can result in personal injury or material damage if ignored.








The two-line display makes it possible to view both the calculation formula and its result at the same time.
A separator symbol is displayed every three digits when the integer part of the mantissa has more than three dig- its.
Before getting started...
Before starting a calculation, you must first enter the cor- rect mode as indicated in the table below.

REG Statistical Calculations

Calculation Mode: COMP Angle Unit: Deg Exponential Display Format: Norm 1 Fraction Display Format: ab/c Decimal Point Character: Dot

A multi-statement is an expression that is made up of two or more smaller expressions, which are joined using a colon ( : ). • Example: To add 2 + 3 and then multiply the result by 4
2 + 3 p \ g - 4 =
Disp · =

This calculator can display up to 10 digits. Larger values are automatically displayed using exponential notation. In the case of decimal values, you can select between two formats that determine at what point exponential notation is used. • To change the exponential display format, press the F key a number of times until you reach the exponential display format setup screen shown below.
uNorm 1 With Norm 1, exponential notation is automatically used for integer values with more than 10 digits and decimal values with more than two decimal places.
uNorm 2 With Norm 2, exponential notation is automatically used for integer values with more than 10 digits and decimal values with more than nine decimal places.
You can use the display setup (Disp) screen to specify the symbols you want for the decimal point and 3-digit sepa- rator. • To change the decimal point and separator symbol set- ting, press the F key a number of times until you reach the setup screen shown below.

k Arithmetic Calculations
Use the F key to enter the COMP Mode when you want to perform basic calculations.
sin 2.34 10–5 → S 2.34 e D 5

1 5 2 3
13 15.00
2 3 1 4 11 12
1 C 2 C 3 =
4 11 12.00
uDecimal ↔ Fraction Conversion
2.75 = 2.75
2 3 4.00
11 4.00
1 2.00
1 2.00

uMixed Fraction ↔ Improper Fraction
5 3 2 3 1 2 3.00
A B
5 3.00
1 2 3.00
1500 - 12 A v
660 \ 880 A v
2500 - 15 A v +
3500 - 25 A v ,

168 + 98 + 734 = g A j 1 p 1 - 20 A v ,
* As shown here, if you want to use the current Answer Memory value in a mark up or discount calculation, you need to assign the Answer Memory value into a variable and then use the variable in the mark up/discount calculation. This is because the calculation performed when v is pressed stores a result to Answer Memory before the , key is pressed.
300 + 500 A v
46 , 40 A v e 8 =
Calculations
2.258 = 2.258
I 2.258
12 I 34 I 56 I - 3.45 = 43°24°31.2
* · (15%, 20%)

200 \ 7 - 14 =
F 1(Fix) 3 400.00000 FIX (Specifies three decimal places.)
200 \ 7 =
(Internal calculation continues using 12 digits.)
28.57100
400.00000
The following performs the same calculation using the specified number of decimal places.
200 \ 7 =
28.57100
(Internal rounding) A Q
28.57100
399.99400
F 2(Sci) 2 1 \ 3 = 3.3–01 SCI
- 14 = · - 14 =

Use the F key to enter the COMP Mode when you want to perform a calculation using memory.
k Answer Memory

23 9 32 23 + 9 A j 3 (M+)
53 6 47 53 , 6 |
) 45 2 90 45 - 2 A {
(Total) –11 0 3 (M+)
193.2 28 6.9
193.2 A j 1 \ 23 =
p 1 \ 28 =
Use the F key to enter the COMP Mode when you want to perform scientific function calculations.

Functions
(90° = radians = 100 grads)
q 2 (Rad) A V R L 2 \ 2 T = g \ A x =
A g 0.741 =
Functions
π 2 · π 3

Antilogarithms
ln e 1 T p P =
Squares, Cubes, Reciprocals, Factorials, Random Numbers, π , and Permutation/Combination
1 1 3 4
R 3 a , 4 a T a =

0.66400
(The above value is a sample only. Results differ each time.)
7 A m 4 =
10 n 4 =
q 1(Deg)
4.25 A v 2(R) =
243.5070629 4 . 2 5 r
Rec ( r , θ ))
x 1 A F 2 P 60 T =
y 1.732050808 0 o
(210)

r 2 f 1 P L 3 T =
θ 1.047197551 0 o
→ 56.088 10 3 56088 = J (km)
→ 81.25 10 –3 0.08125 = J (mg)
SD
Standard Deviation
Use the F key to enter the SD Mode when you want to perform statistical calculations using standard de- viation.

To recall this type of value: Perform this key operation: Σx2 A U 1 Σx A U 2 n A U 3 o A X 1 σn A X 2 σn-1 A X 3
Each time you press S to register your input,
the number of data input up to that point is
indicated on the display (n value).
54 S 51 S 55 S 53 S S 54 S 52 S
Sample Standard Deviation (σn1) = 1.407885953 A X 3 =
Population Standard Deviation (σn) = 1.316956719 A X 2 =
Arithmetic Mean (o) = 53.375 A X 1 =
Number of Data (n) = 8 A U 3 =
Sum of Values (Σx) = 427 A U 2 =
Sum of Squares of Values (Σx2 ) = 22805 A U 1 =


Use the F key to enter the REG Mode when you want to perform statistical calculations using regression.
1 2 3 P w r Inv Q uad
r e

To recall this type of value: Perform this key operation:
Σx2 A U 1 Σx A U 2 n A U 3 Σy2 A U r 1 Σy A U r 2 Σxy A U r 3 o A X 1 xσn A X 2 xσn-1 A X 3 p A X r 1 yσn A X r 2 yσn-1 A X r 3 Regression coefficient A A X r r 1 Regression coefficient B A X r r 2
Regression calculation other than quadratic regression
Correlation coefficient r A X r r 3 m A X r r r 1 n A X r r r 2
To recall this type of value: Perform this key operation:
Σx3 A U r r 1 Σx2y A U r r 2 Σx4 A U r r 3 Regression coefficient C A X r r 3 m1 A X r r r 1 m2 A X r r r 2 n A X r r r 3
uLinear Regression • The regression formula for linear regression is: y = A + Bx.

Pressure 10°C 1003 hPa 15°C 1005 hPa 20°C 1010 hPa 25°C 1011 hPa 30°C 1014 hPa
Each time you press S to register your input,
the number of data input up to that point is
indicated on the display (n value).
20 P1010 S 25 P 1011 S 30 P 1014 S
Regression Coefficient A = 997.4 A X r r 1 =
Regression Coefficient B = 0.56 A X r r 2 =
Correlation Coefficient r = 0.982607368 A X r r 3 =
Atmospheric Pressure at 5°C = 994.6
E D 5 F A X r r r 2 =
Temperature at 1000 hPa = 4.642857143
1000 A X r r r 1 =
Coefficient of Determination = 0.965517241
A X r r 3 K =
Sample Covariance = 35 E A U r 3 , A U 3 - A X 1 -
A X r 1 F \ E A U 3 , 1 F =
Temperature Atmospheric

uLogarithmic, Exponential, Power, and Inverse
Logarithmic Regression y A B In x Exponential Regression y A eB·x (In y In A + Bx) Power Regression y A xB (In y In A + BIn x) Inverse Regression y A B 1/x
uQuadratic Regression • The regression formula for quadratic regression is: y = A + Bx + Cx2.
xi yi 29 1.6 50 23.5 74 38.0 103 46.4 118 48.0
29 P 1.6 S 50 P 23.5 S 74 P 38.0 S 103 P 46.4 S 118 P 48.0 S
Regression Coefficient A = –35.59856934 A X r r 1 =
Regression Coefficient B = 1.495939413 A X r r 2 =
Regression Coefficient C = – 6.71629667 10 –3
A X r r 3 =
n when xi is 16 = –13.38291067 16 A X r r r 3 =
m1 when yi is 20 = 47.14556728 20 A X r r r 1 =
m2 when yi is 20 = 175.5872105 20 A X r r r 2 =

k When you have a problem
If calculation results are not what you expect or if an error occurs, perform the following steps.
If the above steps do not correct the problem, press the 5 key. The calculator performs a self-check operation and deletes all data stored in memory if any abnormality is detected. Make sure you always keep written copies of all important data.
The calculator is locked up while an error message is on the display. Press t to clear the error, or press e or r to display the calculation and correct the problem. See “Error Locator” for details.


Calculations are performed in the following order of prec- edence.
1 Coordinate transformation: Pol (x, y), Rec (r, θ ) 2 Type A functions: With these functions, the value is entered and then the function key is pressed. x3, x2, x1, x!, ° ’ ” m, m1, m2, n Angle unit conversions (DRG') 3 Powers and roots: ^ (xy), x
4 ab/c 5 Abbreviated multiplication format in front of π, e (natu- ral logarithm base), memory name, or variable name: 2π, 3e, 5A, πA, etc. 6 Type B functions: With these functions, the function key is pressed and then the value is entered.
–24 = –16
,

This calculator uses memory areas, called “stacks,” to tem- porarily store values (numeric stack) and commands (com- mand stack) according to their precedence during calcu- lations. The numeric stack has 10 levels and the command stack has 24 levels. A stack error (Stack ERROR) occurs whenever you try to perform a calculation that is so com- plex that the capacity of a stack is exceeded.
1 2 3 4 5
1 2 3 4 5 6 7
Numeric Stack Command Stack 1

Internal digits: 12 Accuracy*: As a rule, accuracy is ±1 at the 10th digit.
sinx DEG 0 x 4.4999999991010
RAD 0 x 785398163.3
GRA 0 x 4.9999999991010
cosx DEG 0 x 4.5000000081010
RAD 0 x 785398164.9
GRA 0 x 5.0000000091010
tanx DEG Same as sinx, except when x = (2n-1)90.
RAD Same as sinx, except when x = (2n-1)π/2.
GRA Same as sinx, except when x = (2n-1)100. sin–1x 0 x 1 cos–1x
tan–1x 0 x 9.9999999991099
sinhx 0 x 230.2585092 coshx
sinh–1x 0 x 4.9999999991099
cosh–1x 1 x 4.9999999991099
tanhx 0 x 9.9999999991099
tanh–1x 0 x 9.99999999910–1
logx/lnx 0 x 9.9999999991099
10x –9.9999999991099 x 99.99999999 ex –9.9999999991099 x 230.2585092 x 0 x 1 10100
x2 x 1 1050
1/x x 1 10100 ; x G 0
3 x x 1 10100
x! 0 x 69 (x is an integer)
nPr 0 n 11010, 0 r n (n, r are integers) 1 {n!/(n–r)!} 110100
Functions Input Range

nCr 0 n 11010, 0 r n (n, r are integers) 1 [n!/{r!(n–r)!}] 110100
Pol(x, y) x, y 9.9999999991049
(x2+y2) 9.9999999991099
Rec(r, ) 0 r 9.9999999991099
°’ ” 0 b, c x 110100
Decimal ↔ Sexagesimal Conversions 0°0°0° x 999999°59° x 0: –110100 ylogx 100 ^(xy) x0: y 0 x 0: yn, (n is an integer) However: –110100 ylog x 100 y 0: x G 0 –110100 1/x logy 100 x y y0: x 0 y 0: x2n1, (n G 0; n is an integer) However: –110100 1/x log y 100
1 2n+1
Total of integer, numerator, and denominator must be 10 digits or less (including division marks).
x 11050
xn, yn, o, p : n G 0 xn–1, yn–1, A, B, r : n G 0, 1
y 11050 (REG)
n 110100
* For a single calculation, calculation error is ±1 at the 10th digit. (In the case of exponential display, calcula- tion error is ±1 at the last significant digit.) Errors are cumulative in the case of consecutive calculations, which can also cause them to become large. (This is also true of internal consecutive calculations that are performed in the case of ^(xy), x y , x!,
3 , nPr, nCr, etc.) In the vicinity of a function’s singular point and point of inflection, errors are cumulative and may become large.
Functions Input Range · 1 n

The type of battery you should use depends on the model number of your calculator.
fx-85MS/fx-300MS The TWO WAY POWER system actually has two power supplies: a solar cell and a G13 Type (LR44) button battery. Normally, calculators equipped with a solar cell alone can operate only when relatively bright light is present. The TWO WAY POWER system, however, lets you continue to use the calculator as long as there is enough light to read the display.
u To replace the battery
1 Remove the six screws that hold the back cover in place and then remove the back cover.
2 Remove the old battery.
3 Wipe off the sides of new battery with a dry, soft cloth. Load it into the unit with the positive k side facing up (so you can see it).
4 Replace the back cover and secure it in place with the six screws.
5 Press 5 to turn power on. Be sure not to skip this step.
Screw Screw

fx-83MS/fx-270MS/fx-350MS This calculator is powered by single G13 Type (LR44) button battery.
Dim figures on the display of the calculator indicate that battery power is low. Continued use of the calculator when the battery is low can result in improper operation. Replace the battery as soon as possible when display figures become dim.
1 Press A i to turn off power.
2 Remove the screw that holds the battery cover in place and then remove the battery cover.
3 Remove the old battery.
4 Wipe off the sides of new battery with a dry, soft cloth. Load it into the unit with the positive k side facing up (so you can see it).
5 Replace the battery cover and secure it in place with the screw.
6 Press 5 to turn power on.
Screw

fx-82MS This calculator is powered by a single AA-size battery.
Dim figures on the display of the calculator indicate that battery power is low. Continued use of the calculator when the battery is low can result in improper operation. Replace the battery as soon as possible when display figures become dim.
1 Press A i to turn power off.
2 Remove the six screws that hold the back cover in place and then remove the back cover.
3 Remove the old battery.
4 Load a new battery into the unit with its positive k and negative l ends facing correctly.
5 Replace the back cover and secure it in place with the six screws.
6 Press 5 to turn power on.
Auto Power Off Calculator power automatically turns off if you do not perform any operation for about six minutes. When this happens, press 5 to turn power back on.
Screw Screw

Power Supply:
Single G13 Type button battery (LR44) fx-85MS/fx-300MS:
Solar cell and a single G13 Type button battery (LR44)
Battery Life:
fx-82MS: Approximately 17,000 hours continuous display of flashing cursor. Approximately 2 years when left with power turned off. fx-83MS/fx-270MS/fx-350MS:
Approximately 9,000 hours continuous display of flashing cursor. Approximately 3 years when left with power turned off. fx-85MS/fx-300MS:
Approximately 3 years (1 hour use per day).
Dimensions:
fx-82MS: 18.6 (H) 85 (W) 156 (D) mm 3/4 (H) 3 3/8 (W) 61/8 (D) fx-83MS/fx-85MS/fx-270MS/fx-300MS/fx-350MS:
12.2 (H) 85 (W) 155 (D) mm 1/2 (H) 3 3/8 (W) 61/8 (D)
Weight:
100 g (3.5 oz) including battery

CASIO COMPUTER CO., LTD.
6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, Japan
SA0311-C Printed in China
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.