Gebruiksaanwijzing /service van het product GB5MV-10-LD van de fabrikant Cecilware
Ga naar pagina of 27
GB5MV-10-LD Operation Manual NL48P July 2005 GB6MP-10-LD-U GB8MP-10-LD-U.
CONTENTS Important Owner Information _____________________________________1 Introduction ____________________________________________________1 Important Safety Instructions ___________________________.
IMPORTANT OWNER INFORMATION Record the model number, serial number (identification plate is located behind front door), voltage and purchase date of your Cecilware Cappuccino Dispenser in the spaces below. Please have the information available when calling Cecilware for assistance.
IMPORTANT! Read the following important safety instructions to avoid personal injury or death, and to avoid damage to the equipment or property. IMPORTANT SAFETY INSTRUCTIONS WARNINGS The GB8MP - 10 - LD - U ( only ) is equipped with two (2) power switches and two (2) 120 volt grounded power cords.
PLUG CONFIGURATION NEMA 5-15P NEMA 5-15R NEMA 5-15P NEMA 5-15R (2) DEDICATED OUTLETS 120 V 15 A Figure # 1 FOR GB8 MODELS ONLY MODEL DESCRIPTION GB8M P - 10 - LD - U (shown) GB5 - LD - U & GB6M P .
UNPACKING INSTRUCTIONS Carefully unpack the Cappucci no Dispenser Unit and inspect immediately for shipping damage. Your Cappuccino Dispenser Unit was shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the factory.
START - UP PROCEDURE Caution: Make sure that the Heater Switches, are in the OFF position. 1. Co nnect the ¼ inch copper waterlines to the ¼ inch flare water inlet fittings of the valves. 2. Plug the power cords into dedicated receptacles. 3. Activate the Power Switch (Toggle Up).
TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock, DISCONNECT POWER CORDS before repairing or replacing any internal components of the unit. Before any attempt to replace a component be sure to check all electrical connections for proper connection.
Model L690A (Rev. B) Dual Probe Liquid Level Controller Overview - The L690A is a Dual Probe Liquid Level Co ntroller designed to maintain a specific level of water in the tank. This device utilizes two level probes for increased reliability. Independent maximum fill timers are incorporated in the controller for overflow protection.
- MOVE RINSE SWITCH TO "RINSE". 2. EMPTY DRIP TRAY WASH, RINSE, AND SANITIZE* - MOVE RINSE SWITCH TO "SERVE". - PUSH AND HOLD EACH DISPENSE BUTTON 3 TO 5 SEC. - POSITION PAN UNDER DISPENSE TUBES. 1. RINSE WHIPPER CHAMBERS 4. SANITIZE* ALL EXTERIOR SURFACES.
.
GB5MV-10-LD (VISTA) 5 Flavor Cappuccino Dispenser Door not shown PRODUCT GUIDE DRIP TRAY PAN POWER SWITCH RINSE SWITCH GRILL HOPPER (4) (CD185) 5 Lbs 5 Lbs 5 Lbs HEATER SWITCH WHIPPER CHAMBER HOPPER (.
10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD185) 10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD180) 27.0" 21.5" DRIP TRAY PAN GRILL DRIP TRAY PAN (2) GRILL SLANTED WHIPPER CH.
11 5 7 1 12 8 6 4 3 10 2 9 WHIPPER CHAMBER 13 IMPORTANT: SLANTED WHIPPER CHAMBERS (SEE BELOW) ARE NOT INTERCHANGEABLE WITH STANDARD STRAIGHT WHIPPER CHAMBERS.
PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 HOPPER COVER AUGER MOTOR #CD175 (90 RPM).
PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 AUGER MOTOR #CD175 (90 RPM) HOPPER COVER.
BODY ASS'Y GB5MV-10-LD (Vista) DESCRIPTION ITEM QTY P/N.
DOOR ASS'Y GB5MV-10-LD (Vista) DESCRIPTION ITEM QTY P/N.
.
1 2 3 4 5 6 7 8 9 10 11 ITEM GB6MP GB8MP DESCRIPTION OF COMPONENTS FOR MACHINES NO. P/N QTY P/N QTY WITH MOLDED FRONT GB6MP AND GB8MP 1 SK61A 1 SK43A 1 INSIDE DOOR PANEL, UPPER DOOR 2 SK65A 1 SK45A 1 .
DESCRIPTION ITEM QTY P/N 21.
DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 12" WIDE, 4.8" DEEP, 16.5" HIGH. APPROX. 3.7 GAL..
DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 15" WIDE, 6" DEEP, 18" HIGH. APPROX. 6 GAL..
WATER INLET VALVE AUGER DOOR UNIT WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH MAIN UNIT DISPENSE VALVE HI-LIMIT THERMOSTAT HEATER SWITCH RINSE SWITCH A2 44 NO 32 NC 22 NC 14 NO A1 43 NO 31 NC 21 NC 13 NO GND 5-15P 15A-1.
GB6M-10-LD-U.
GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - LEFT SIDE - 120V NE195 SHEET 1 OF 2 WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER DISPLAY LIGHTS REV A.
GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - RIGHT SIDE - 120V NE195 SHEET 2 OF 2 WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER DISPLAY LIGHT REV A.
Een belangrijk punt na aankoop van elk apparaat Cecilware GB5MV-10-LD (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Cecilware GB5MV-10-LD heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Cecilware GB5MV-10-LD vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Cecilware GB5MV-10-LD leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Cecilware GB5MV-10-LD krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Cecilware GB5MV-10-LD bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Cecilware GB5MV-10-LD kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Cecilware GB5MV-10-LD . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.