FRAMING NAILER 21° ANGLE / 10 GAUGE 9751 1 93909 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 2 SPECIFICA TIONS Nail Size .1 13” to .131” Thick Shank, 2” to 3-1/2” Long; 21° Full Head Magazine Capacity 60 Nails Operating PSI 70 to 125 PSI * Required A verage Air Flow 3 - 3.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 3 7. Do not overreach . Keep proper footing and balance at all times. Do not reach over or across running machines or air hoses. 8. Use eye and ear protection . Always wear ANSI approved impact safety goggles and appropriate hearing protection.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 4 impaired while taking drugs. If there is any doubt, do not operate the tool. 18. Use proper size and type extension cord . If an extension cord is required, it must be of the proper size and type to supply the correct current to the compressor without heating up.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 5 UNP ACKING When unpacking, check to make sure all the parts shown on the Parts List on page 11 are included. If any parts are missing or broken, please call Harbor Freight T ools at the number shown on the cover of this manual as soon as possible.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 6 T esting The Full Sequential Safety T rip Mechanism W arning: Even though the nailer should be empty during this procedure, A LWA Y S point the Nailer at a piece of scrap wood when testing.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 7 OPERA TION NOTE: For additional references to the parts listed below , refer to the Assembly Diagram on page 1 1. 1. Adjust the Exhaust Cover (4) to direct exhaust as desired.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 8 T o Adjust The Depth T o Which A Nail Is Driven 1. The depth to which a nail is driven is controlled by the Safety (38). (See Figures B and C). 2. T o adjust the depth of drive, loosen the Screw (37).
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 9 SAFETY (38) RUBBER COVER (39) SCREW (37) FIGURE C Anytime any maintenance or repairs are done (including clearing jams), FIRST : 1. Disconnect the Nailer from the air hose. 2.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 10 INSPECTION, MAINTENANCE, AND CLEANING 1. CAUTION: Always disconnect the Framing Nailer from its compressed air supply source before performing any inspection, maintenance, or cleaning.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 1 1.
SKU 9751 1 93909 For T echnical Questions, Please Call 1-800-444-3353 Page 12 PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE T OOL ONL Y .
Een belangrijk punt na aankoop van elk apparaat Central Pneumatic 93909 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Central Pneumatic 93909 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Central Pneumatic 93909 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Central Pneumatic 93909 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Central Pneumatic 93909 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Central Pneumatic 93909 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Central Pneumatic 93909 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Central Pneumatic 93909 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.