DO NOT INST ALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INST ALLA TION. W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury or loss of life.
2 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Description The UVSTR36 and UVCVR36 models are ventless fireboxes designed for installation with any ventless gas log set for a see-through application and certified to ANSI Z21.1 1.2 standards.
3 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 General Information Installation Precautions This Majestic Fireplaces firebox and its components have been tested and will operate safely when installed in accordance with this installation manual.
4 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 FP677 Fig. 2 UVCVR36 Series specification and framing dimensions. UVCVR36 Specifications 36" 36" 40 " " .
5 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Minimum Clearances Sidewall Clearances: The clearance from the side of the firebox to any com- bustible wall should not be less than 1 1" . (Fig. 3A) Ceiling Clearances: The ceiling height should not be less than 42" from the top of the fireplace opening.
6 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Installation Installing Outside Air Kit An outside air kit may be installed in all UVSTR/CVR Series fireboxes. If desired, or if local codes man- date the use of an air kit, then an AKU2 is required to complete the installation (from air kit to out-of-doors).
7 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Install Gas Log Heater 1. Connect the shutoff valve, union and any required approved fittings (See NOTE below) between the valve and the gas line. Access to the gas line on the UV Series firebox is made through the left or right side of the firebox.
8 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Finishing See Page 5, Figure 3 for allowable finishing materials and clearances to combustibles. All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround must be completely sealed with a noncombustible ma- terial.
9 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Install Hood A 2" or 4" Hood can be purchased for the UVSTR36 and the UVCVR36. A Hood must be installed if the mantel falls within the dimensions and location shown in Figure 3. Failure to do so may create a fire hazard.
10 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Keep the control compartment, logs and burner area surrounding the logs clean by carefully vacuuming or brushing at least twice a year or as necessary . THE LOGS CAN GET VER Y HOT – HANDLE ONL Y WHEN COOL.
1 1 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 7 1 2 4 5 6 3 960 UVCVR Parts 4/22/98 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
12 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 1 2 3 4 5 FP686 UVSTR Parts 4/22/98 UVSTR V ent Free Firebox Ref. Description UVSTR 1. Brick - Filler 3079148 2. Brick - Side 3079147 3. Brick - Hearth 3087102 4. Screen Assembly (Screens and Rod) 3049121 5.
13 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 Outside Air Completes connection from air kit to out-of-doors AKU2 T ermination 2" Hood For heater up to 40,000 BTU's with a mantel .
14 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960.
15 UVS TR / UVCVR Series V ent-F r ee F ir eboxes 7412960 BASIC W ARRANTY CFM Corporation (hereinafter referred to collect ively as the Company) warrants that your new V ermont Castings or Majestic Ga.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
Een belangrijk punt na aankoop van elk apparaat CFM UVSTR36 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen CFM UVSTR36 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens CFM UVSTR36 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding CFM UVSTR36 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over CFM UVSTR36 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van CFM UVSTR36 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de CFM UVSTR36 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met CFM UVSTR36 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.