Gebruiksaanwijzing /service van het product Country 8 Mk2 van de fabrikant Charnwood
Ga naar pagina of 11
Operating and Installation Instructions CHARNWOOD Country 8 MkII and Country 12 MkII Flat Top, Low Canopy & High Canopy Multifuel Roomheaters Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K. Tel: (01983) 537799 Fax: (01983) 537788 E-Mail: charnwood@ajwells.
Contents Operating Instructions Fuels ................................................................... 3 Door Operation ................................................... 3 Multifuel Grate ................................................... 3 Lighting .
Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been swept, is sound and free from any obstructions. FUELS The following fuels may be burnt on this stove.
position by moving the tool up until the handle is in the 1 o'clock position. The grate is put into the wood position by moving the tool down until the handle is in the 5 o'clock position. To riddle the appliance when burning solid fuels the tool should be moved between the 1 o'clock and 3 o'clock positions several times.
that it begins to block the passage of air into the firebox at the side of the grate. When this is the case do not remove all of the ash using the riddling mechanism but keep a layer about half an inch thick as this enables the wood to burn more effectively.
sweep the chimney through the appliance. First remove the side fire plates, front firebars and the throat plate. Then sweep the chimney ensuring that soot is removed from all horizontal surfaces after sweeping.
HEALTH AND SAFETY PRECAUTIONS Please take care when installing the stove that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash with plenty of water.
The hot water system should be a gravity circuit and must be correctly vented as shown in Fig. 4. The steel boiler together with a double feed indirect hot water storage cylinder to BS:1566 part 1 sho.
chimney may be swept through the appliance. Horizontal lengths of flue must be kept to a minimum and should not be more than 150mm (6 inches) long. The sealing face of the flue collar should be coated with fire cement before fixing to the body of the stove using the two screws provided.
Ø154 Ø154 71 299 110 46 Ø154 71 299 110 71 299 110 Country 8 HC (High Canopy) Country 8 LC (Low Canopy) Country 8 FT (Flat Top) 552 508 381 1012 526 526 526 381 752 552 513 322 513 381 513 513 322 .
Country 12 MkII Dimensions (All dimensions are in mm) 180 210 180 210 180 210 655 1098 320 462 386 518 1158 584 106 45 655 793 320 Ø154 462 386 518 853 584 125 489 45 658 595 320 Ø154 462 386 518 71.
Een belangrijk punt na aankoop van elk apparaat Charnwood Country 8 Mk2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Charnwood Country 8 Mk2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Charnwood Country 8 Mk2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Charnwood Country 8 Mk2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Charnwood Country 8 Mk2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Charnwood Country 8 Mk2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Charnwood Country 8 Mk2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Charnwood Country 8 Mk2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.