Page 1 of the Coleman TG9S user manual — EFFICIENCY RATING CERTIFIED
Pagina 1 · klik om te vergroten
Pagina 1

DESCRIPTION These compact units employ induced combustion, reliable hot surface ignition and high heat transferaluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and venr piping.

Coleman TG9S — TECHNICAL GUIDE diagram (page 1)
Afb. 1
Coleman TG9S — TECHNICAL GUIDE diagram (page 1)
Afb. 2
Coleman TG9S — TECHNICAL GUIDE diagram (page 1)
Afb. 3

TECHNICAL GUIDE

95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES

WARRANTY Lifetime limited warranty on the heat exchanger. 10-year heat exchanger warranty on commercial applications. 5-year limited parts warranty.

MODELS: TG9S

NATURAL GAS 40 - 130 MBH INPUT

  • FEATURES
  • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
  • Compact, easy to install, ideal height 33" tall cabinet.
  • Blower-off delay for cooling SEER improvement.
  • Easy access to controls to connect power/control wiring.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Low unit amp requirement for easy replacement application.
  • Single wire twinning or staging feature available.
  • All models are convertable to use propane (LP) gas.
  • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
  • 100% shut off main gas valve for extra safety.
  • 4 speed, direct drive PSC motor.
  • 24V, 40 VA control transformer and blower relay supplied for add-on cooling.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Secondary heat exchanger made of corrosion resistant stainless steel materials.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch.
  • Solid removable bottom panel allows easy conversion.
  • Airflow leakage less than 1% of nominal airflow at ductblaster conditions.
  • No knockouts to deal with, making installation easier.
  • Movable duct connector flanges for application flexibility.
  • Quiet inducer operation.
  • Inducer rotates for easy conversion of venting options.
  • Fully supported blower assembly for easy access and removal of blower.
  • External air filters used for maximum flexibility in meeting customers IAQ needs.
  • Protection included from air intake, exhaust vent, or condensate blockage.
  • Patent pending self priming internal condensate trap design for easy installation.
  • Venting applications - may be installed as a either 2-pipe (sealed combustion) or single-pipe vent (using indoor combustion air.
  • No special vent termination required.
  • 1/4 turn knobs provided for easy door removal.

EFFICIENCY RATING CERTIFIED

ISO 9001 Certified Quality Management System

Due to continuous product improvement, specifications are subject to change without notice.

Visit us on the web at www.york.com for the most up-to-date technical information.

Additional efficiency rating information can be found at www.gamanet.org

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

Page 2 of the Coleman TG9S user manual — Ratings & Physical / Electrical Data
Pagina 2 · klik om te vergroten
Pagina 2
Coleman TG9S — Cabinet & Duct Dimensions diagram (page 2)
Afb. 4 · Cabinet & Duct Dimensions

Cabinet & Duct Dimensions

Coleman TG9S — Cabinet & Duct Dimensions diagram (page 2)
Afb. 5 · Cabinet & Duct Dimensions
BTUH (kW) InputNominal CFM (m3/min)Cabinet SizeCabinet Dimensions (Inches)Approximate Operating Weights ABCLbs TG9S040A08MP11800A14 1/213 3/811 3/4113 TG9S060A10MP111000A14 1/213 3/811 3/4118 TG9S060B12MP111200B17 1/216 3/813 1/4122 TG9S080B12MP111200B17 1/216 3/814 3/4126 TG9S080C16MP111600C2119 7/816 1/2136 TG9S080C22MP112200C2119 7/816 1/2139 TG9S100C16MP111600C2119 7/818 1/4142 TG9S100C20MP112000C2119 7/818 1/4145 TG9S120D16MP111600D24 1/223 3/821 3/4153 TG9S120D20MP112000D24 1/223 3/821 3/4156 TG9S130D20MP112000D24 1/223 3/8No Hole160

Ratings & Physical / Electrical Data

Coleman TG9S — Ratings & Physical / Electrical Data diagram (page 2)
Afb. 6 · Ratings & Physical / Electrical Data
InputOutputNominal AirflowTotal Unit AmpsAFUEAir Temp. RiseMax Over-Curren ProtectMin. wire Size t (awg) @ 75 ft one wayMax. Outlet Air Temp MBHCFM°F°F TG9S040A08MP11388008.095.530-601514155 TG9S060A10MP1157100010.095.530-601514155 TG9S060B12MP1157120010.095.530-601514160 TG9S080B12MP1176120010.095.535-651514165 TG9S080C16MP1176160011.595.535-651514155 TG9S080C22MP1176220017.095.535-652012155 TG9S100C16MP1195160011.595.535-651514165 TG9S100C20MP1195200017.095.535-652012155 TG9S120D16MP11114160011.595.540-701514170 TG9S120D20MP11114200017.095.535-652012160 TG9S130D20MP11123.5200017.095.545-752012165

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.

Page 3 of the Coleman TG9S user manual — ACCESSORIES
Pagina 3 · klik om te vergroten
Pagina 3

FILTER PERFORMANCE The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters.

SIDEWALL VENT TERMINATION KIT - S1-1HT0901 (3") S1-1HT0902 (2") For use on sidewall, two-pipe installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home.

All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabi- net. DO NOT attempt to install any filters inside the furnace.

CONDENSATE NEUTRALIZER KIT - 1NK0301 Neutralizer cartridge has a 1/2" plastic tube fittings for instal- lation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts (p/n 026-30228-000).

SIDE RETURN FILTER RACKS - S1-1SR0200 - All Models S1-1SR0402 - All Models S1-1SF0101 - All Models (Upflow Only)

Recommended Filter Sizes (High velocity 600 FPM)

CFMCabinet SizeSide (in)Bottom (in) 800A16 x 2514 x 25 1000A16 x 2514 x 25 1200A16 x 2514 x 25 1200B16 x 2516 x 25 1600B16 x 2516 x 25 1600C16 x 2520 x 25 2000C(2) 16 x 2520 x 25 2200C(2) 16 x 2520 x 25 2000D(2) 16 x 2522 x 25

BOTTOM RETURN FILTER RACKS - S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets S1-1BR0521 or 1BR0621 - For 21” cabinets S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets 1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the furnace cabinet.

COMBUSTIBLE FLOOR BASE KIT - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential overheating situations.tible floor base kit provides access for combustible airflow. S1-1CB0514 - For 14-1/2” cabinets S1-1CB0517 - For 17-1/2” cabinets S1-1CB0521 - For 21” cabinets S1-1CB0524 - For 24-1/2” cabinets

NOTES:

1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters. 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter.

Unit Clearances to Combustibles

EAC TRANSITION KITS - For installation of EAC accessories with these furnaces to provide easy transition of return airflow through the EAC to get the proper sealing and reduced airflow leakage. S1-1TK1001 - For all models using side return S1-1TK1014 - For 14-1/2” cabinets using bottom return S1-1TK1017 - For 17-1/2” cabinets using bottom return S1-1TK1021 - For 21” cabinets using bottom return S1-1TK1024 - For 24-1/2” cabinets using bottom return

ApplicationUpflowDownflowHorizontal Top1"0"0" Vent0"0"0" Rear0"0"0" Side0"0"1" Front*0"0"0" FloorCombustibleCombustible1Combustible ClosetYesYesYes Line ContactNoNoYes

HIGH ALTITUDE PRESSURE SWITCHES - For installation where the altitude is less than 5,000 feet it is not required that the pressure switch be changed. For alti- tudes above 5,000 feet, see kits below. S1-1PS3306 - 040, 080 S1-1PS3307 - 060 S1-1PS3302 - 100, 120, 130

1. For combustible floors only when used with special sub-base.

* - 24" clearance in front and 18" on side recommended for service access. All furnaces approved for alcove and attic installation.

ACCESSORIES

PROPANE (LP) CONVERSION KIT - S1-1NP0347 - All Models except 130K Model S1-1NP0501 - 130K Model This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation.

ROOM THERMOSTATS - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation.

1H/1C, manual change-over electronic non-programmable thermostat. 1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory.

CONCENTRIC VENT TERMINATION - S1-1CT0302 (2") S1-1CT0303 (3") For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through single common hole. Elimi- nates unslightly elbows for a cleaner installation.

Page 4 of the Coleman TG9S user manual — NOTES:
Pagina 4 · klik om te vergroten
Pagina 4

Blower Performance CFM - Any Position (without filter) - Bottom Return

ModelsSpeedBottom Airflow Data (SCFM) Ext. Static Pressure (in. H2O) 0.10.20.30.40.50.60.70.80.91.0 TG9S040A08MP11High112810771035996950891842781708646 Medium High934909867834818780745696631584 Medium Low746735714679653629596585547494 Low676652627601581542516474441383 TG9S060A10MP11High136012901230116511031043983925820776 Medium High12511198114010891038979916854790718 Medium Low108110621015964917871819767710634 Low909900852812769739712662612547 TG9S060B12MP11High1492144213781325124311761075966849655 Medium High123612011161113910821011919830715590 Medium Low986950961916872831757703600510 Low824795783744713659624554489389 TG9S080B12MP11High159715371484143513701286123011551075925 Medium High1338130712731223117911231065998928812 Medium Low11131094107710431008972924868803798 Low937916900877854817775718639560 TG9S080C16MP11High1919186518021738167116001517141413221201 Medium High1532153315131499146514161352128311981084 Medium Low123213131291128012501209120711481055937 Low826821853858838817794776760711 TG9S080C22MP11High2529243523382256216220411920179416541501 Medium High2166211120702001192718491719161414991344 Medium Low1697168516641631158615311466139313151185 Low138313771358133612851244119911471048925 TG9S100C16MP11High1909188018231776170616371562147413751252 Medium High1465146314691485147714161386132412501114 Medium119012221216121512241189115811451087996 Low787834819836819810790761690707 TG9S100C20MP11High2284220521142021193418481752165315051397 Medium High1967190518241763171216281551147313791213 Medium Low1610156315131480143013671319126111011012 Low13261304126712321183114310801003871798 TG9S120D16MP11High2020199419581878180517401647156014451294 Medium High1551155915491520149414511383133412531145 Medium Low127012671269126912541227118511211051985 Low932916905894876828803725754696 TG9S120D20MP11High2341224521532072197718761769164215061306 Medium High2002195218781823173916571563145813221185 Medium Low161515791533147314301368128211861091953 Low1352129512591245119011411076998938820 TG9S130D20MP11High2412232922472173204719801887177716551511 Medium High2040200419481876178617381656156214611314 Medium Low1614159115491531145914001335126711801061 Low13271294125712241198117111241036944848

NOTES:

1. Airflow expressed in standard cubic feet per minute (CFM).
2. Motor voltage at 115 V.
Page 5 of the Coleman TG9S user manual — NOTES:
Pagina 5 · klik om te vergroten
Pagina 5

Blower Performance CFM - Any Position (without filter) - Left Side Return

ModelsSpeedLeft Side Airflow Data (SCFM) Ext. Static Pressure (in. H2O) 0.10.20.30.40.50.60.70.80.91.0 TG9S040A08MP11High1131109110531003965921862800733659 Medium High982959935887846795745675628595 Medium Low772736715689661642599568531493 Low636618585569546522486460455370 TG9S060A10MP11High1431137513041244117811091040963861805 Medium High128012261171111710591004930865781731 Medium Low109910501008970919866814759710626 Low914876842812770728694661612545 TG9S060B12MP11High1470140613611309124111551060920775628 Medium High12111186113911011042980896796681545 Medium Low970957927889853796745660568450 Low793781756724694653585530469382 TG9S080B12MP11High160515621514145413931330125111691073940 Medium High13721318128012551205116110931023943849 Medium Low1087107310521003993953897843775709 Low916896881854831802757708642574 TG9S080C16MP11High1956190718461778171716471573148313531209 Medium High1543154315161504147714461382130912021099 Medium Low123812411243124112521242120111401074967 Low906902903910888866859829795743 TG9S080C22MP11High2585249224052321223221372015190217451577 Medium High2098206720361982192818601767167015491331 Medium Low1619162816141584154514881424133912161121 Low133813471327130112621199113810781019938 TG9S100C16MP11High1828182917891768172716711601150513901272 Medium High1422144414371424139613261301125312001100 Medium122412291243123412191193116811351088977 Low813819818814783762756732690642 TG9S100C20MP11High2391228621652079200419341839169215601366 Medium High1945187818381782169416421565145113341163 Medium Low1549153014951430143113651284119210971022 Low1256122911891159108910331008950871784 TG9S120D16MP11High1998198719141858179817211629153014171303 Medium High1512150614921467144114061342128012061097 Medium Low121712191210118511741148111210631012937 Low892870859843814798790745740677 TG9S120D20MP11High2343225321672071197918811785166814731351 Medium High1954189218461781171416371548142912381171 Medium Low15961539151114581399134112541180942988 Low129912611229117711111053993937882782 TG9S130D20MP11High2425233622552157204619661865175816151420 Medium High1979195918991825177316861619151613761225 Medium Low1582156715401488144314061336125211461033 Low13051287123911941159112610621003943831

NOTES:

1. Airflow expressed in standard cubic feet per minute (CFM).
2. Return air is through side opposite motor (left side).
3. Motor voltage at 115 V.
4. Airflow through across motor side (right side) may be slightly less than the data shown above.
Page 6 of the Coleman TG9S user manual — 5005 York Drive Norman, OK 73069
Pagina 6 · klik om te vergroten
Pagina 6

Subject to change without notice. Printed in U.S.A. 400992-CTG-B-0708 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 400992-CTG-A-0608 Johnson Controls Unitary Products

5005 York Drive Norman, OK 73069

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Coleman TG9S

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Coleman TG9S

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Coleman TG9S handleiding-pdf

6 pagina's·193 KB·Verwarmingsoven·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…