Gebruiksaanwijzing /service van het product 85054-90049 van de fabrikant Agilent Technologies
Ga naar pagina of 75
Us er ’s a nd S erv ice G uid e Ag ilen t T ec hnolo gies 85054B 50 Ω Typ e-N Cal ibrati on K it This manual a p plies directly to 8 5 054B cali b ration kits with seria l number prefix 3 1 01A. The c a libration devi ces in thi s kit are i nd ividuall y serialized.
ii 85054B Doc um e ntat ion W arra nty THE MATERIAL CO NTAINED IN THIS D O CUM ENT IS P ROVIDED "AS IS , " AND IS SUBJECT TO BEING CHANGED, WI THOUT NO TICE, IN FUTURE EDITIONS .
Contents iii 1. Gen era l I n f or mat io n Calibr ation K it O v ervi ew . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Ki t Content s . . . . . . . . . . . . . . . . . . . . . . . . . .
iv Contents 5. T r oubles h ootin g Trou bleshoot ing Pro cess . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5- 2 Re t urni n g a K it o r Devi ce to Ag ilent . . . . . . . . . . . . . . . .
85054B 1- 1 1 Gen e ral In forma tio n.
1- 2 8 5054B General Inf or mation Calibrati on Kit Overview Calibr ati on Kit Overview The Agil ent 85054B type-N c alibration kit is used to c alibrate A gilent network analyzers up to 1 8 GHz for m ea surements of components with 50 Ω type-N connector s.
85054B 1-3 General Information Calibrat ion Kit Overvie w Lowband Loads The lowband lo ads are metrolo gy -grade, 50 ohm terminat i ons which have been op ti mized for low b and perfor m ance up to 2 G H z. The r ugged interna l structur e provides for hi ghly repeatable c onnections .
1- 4 8 5054B General Inf or mation Incoming Inspection Inc o mi ng Ins p e c tio n Refer to “Ki t Contents” on p age 1 -2 to ver i fy a complete shipment. Use T abl e 1-1 o n pag e 1-5 to record the serial numbers of all ser i alized devi ces in your ki t.
85054B 1-5 General Information Serial Numbers Serial Nu m ber s A serial number is attached to this c alibration ki t. The first f our digits followed b y a let ter comprise the serial number p refix; the l ast fiv e digits are the suffix, uni que to ea ch calibration ki t.
1- 6 8 5054B General Inf or mation Cali bration K its Docume nt ed i n This Manu al Calibration Kits Documented in This M anua l This manual applies to a ny 85054B cal i bration ki t w hose seria l number pref i x is li s ted on the ti tle page.
85054B 1-7 General Information Preci sion Sl ot l ess Connect or s Prec ision S l ot less C on nectors The female type-N connect ors in this calibration kit are metrology-grad e, precisi on slotless connectors ( PSC).
1- 8 8 5054B General Inf or mation Clarifyin g the Sex of a C onnector Clarify ing the Sex of a C onn e ctor In thi s manual, the sex of ca li bra tion de vi ces and adapt ers a r e r ef erred to in terms of thei r connector interfac e. F or ex amp le, a male open has a male conne c tor .
2-1 2 Spec ifica tion s.
2- 2 85054B Specificati ons En vir onmental R equirements Environment al Req u irements T emperature—What to W atch Out F or Changes i n temperature can a ffect el ectrical c haracteristi c s. T herefore , the op er ating temperatur e is a cri ti cal fa c tor in p erfor m a nce.
85054B 2-3 Specifications Mechanical Characterist ics Mechani cal Ch a ra cteristi cs Mechanical characteris ti cs such a s center c onduc tor protr usion and pin d epth are not performance sp ecific a tions . They are , however , importa nt supplemental cha r acteristi c s related to electrica l perfor mance .
2- 4 85054B Specificati ons Mechanical Character istics NO TE The gages fo r measuring typ e- N connectors c ompensate for the designed offs et of 5.26 m m (0.207 i nch), theref ore, pro tr usion and r ecession r ea dings are in relation to a zer o referenc e plane (as i f the inner a nd outer co nd uctor planes w er e intend ed to b e flush).
85054B 2-5 Specifications Electrical Specifi cations Elec trica l Specif icatio ns The electr ical speci f ications i n T a ble 2- 3 apply to the devices in y our calibrati on kit when connected w ith an Agil ent precision i nterface .
2- 6 85054B Specificati ons Electrical Specifi cat ions.
3-1 3 Us e, Main ten anc e, an d Ca re of the De vic es.
3- 2 8 5054B Use, Maintenance, and Care of the D evi ces Electr ostat ic Disc harge Elect rosta tic Dischar ge Protect ion against ESD (electrosta ti c dischar ge) is ess enti al while connecting , inspect i ng , or cl eaning connect or s attac hed to a st a tic-sensitiv e circuit (s uch as t hose found in test sets) .
85054B 3-3 Use, Maintenance, and Care of t he Devices Visual Inspection Visual Ins pect ion Visual inspection a nd, if neces s ary , clea ni ng should be d one every time a connection i s made. Meta l partic les from the c onnector t hr eads may fal l into the c onnector when i t is disconnect ed.
3- 4 8 5054B Use, Maintenance, and Care of the D evi ces Cleani ng Connect or s Inspect the Pr ecision S lotless C onnectors (female) Preci sion slotle ss female connectors are used to improv e accuracy . The slotl ess contacts are not aff ected by the slight variat ions in male c ontact pin diameter .
85054B 3-5 Use, Maintenance, and Care of t he Devices Cleani ng Connectors Use a l int-free sw ab or clea ning cloth mo istened with isop ropyl alcohol to remove any dirt or stubbor n contaminants on a connector t ha t cannot be r em oved with c ompressed air or nitrogen.
3- 6 8 5054B Use, Maintenance, and Care of the D evi ces Gagi ng Connector s Gagi ng Connec tors The g a g es a v ailable f r om Agilent T echnologies are intended f or preven ti ve maintenance and tr oub leshooting p urposes onl y . (See T abl e 6-1 o n pag e 6-2 fo r par t num be r inf or mation.
85054B 3-7 Use, Maintenance, and Care of t he Devices Gagi ng Connector s When to Gage C onnectors Gage a connec tor at the following times : • Prior to us ing a device f or the f irst time: rec ord the p in depth measur em ent so that i t can be compared with future r eadings .
3- 8 8 5054B Use, Maintenance, and Care of the D evi ces Gagi ng Connector s Gaging Procedures Gaging Male Type-N Connectors NO TE Always ho ld a connec tor gage by the g a ge barrel, b elow the d ial ind i cator . This g i ves the b est stabil i ty , and improv es measurement accuracy .
85054B 3-9 Use, Maintenance, and Care of t he Devices Gagi ng Connector s Fi gu re 3-3 Gaging Male Type-N Connectors.
3- 10 8 5054B Use, Maintenance, and Care of the D evi ces Gagi ng Connector s Gaging F emale Type-N Connectors NO TE Always ho ld a connec tor gage by the g a ge barrel, b elow the d ial ind i cator . This g i ves the b est stabil i ty , and improv es measurement accuracy .
85054B 3-1 1 Use, Maintenance, and Care of t he Devices Gagi ng Connector s Fi gu re 3-4 Gaging F emale Type-N Connectors.
3- 12 8 5054B Use, Maintenance, and Care of the D evi ces Gagi ng Connector s Gaging the Sliding Load Gage the s liding load before eac h use. If the sli d ing load pin depth is out of the ob served pin d ep th limits l isted in T able 2-2 on page 2-4 , refer t o “ Adjusti ng the Sliding Load Pin Depth” on page 3-13 .
85054B 3-13 Use, Maintenance, and Care of t he Devices Gagi ng Connector s NO TE W hen performing p i n depth measureme nts, use different or ientations of the gage within the connector .
3- 14 8 5054B Use, Maintenance, and Care of the D evi ces Gagi ng Connector s If the pin depth is outside t he o bs erved limits listed in T able 2- 2 on page 2 - 4 , use the fol lowing pr ocedur e t o reset i t. Alway s me asur e the sliding lo ad pin dept h b efore att achi ng it to any connector .
85054B 3-15 Use, Maintenance, and Care of t he Devices Gagi ng Connector s Fi gu re 3- 6 Ad just in g the Sliding Load Pin Depth.
3- 16 8 5054B Use, Maintenance, and Care of the D evi ces Connect ions Co nne c ti on s Good connecti ons requi re a ski lled op erator . The most com m on caus e of me asure me n t erro r is bad connections . T he foll ow ing procedure s illustr ate how to make g ood connecti ons.
85054B 3-17 Use, Maintenance, and Care of t he Devices Connections Using a torque wre nc h guarantees tha t the c onnec ti on is not too tight, prev entin g pos sible connector damage. It also guarantees that all connections are equally tight each time.
3- 18 8 5054B Use, Maintenance, and Care of the D evi ces Connect ions 3. Appl y do wnwa rd force perp endic ul ar t o the wrenc h handle . See Figu re 3-8 .
85054B 3-19 Use, Maintenance, and Care of t he Devices Connections 3. Relea s e press ure on the c enter conductor a nd mate the oute r conductor of the sliding load wit h the outer cond uctor o f the cabl e/test port connec tor . T orqu e the connection with a 3/4 inc h torque wrench to approximatel y 135 N-cm (12 i n- lb).
3- 20 8 5054B Use, Maintenance, and Care of the D evi ces Using the Sl iding Load Using th e Sliding Load When perfor m ing a sl i ding load ca libration, i t is recommended tha t the sli d ing r ing b e set at the m arked posi ti ons (ri ng s) along the s liding loa d body .
85054B 3-21 Use, Maintenance, and Care of t he Devices Using the Sl iding Load Figure 3-10 Using the S liding Load.
3- 22 8 5054B Use, Maintenance, and Care of the D evi ces Handli ng and Stor age Ha ndling and S tor a ge • Install the protective end c a ps and st or e the ca l ibration devic es in the foam-lined storage c a se when not i n use. • Never stor e connectors lo ose in a b ox, desk, or bench dra w er .
4-1 4 P erf orm anc e V er ific at ion.
4- 2 8 5054B P erformance V erification Int roductio n In troduct i on The perfor mance of your cali bra tio n kit c an on ly be verif ied b y retur ning the kit to Agilent T echnol ogies for recertifi c ation.
85054B 4-3 P erformance V erification Recer ti f ication Rec ert ification The foll ow ing will b e provided with a recertif ied kit: • a new calibrati on stic ker affixed to the case • a cert i f.
4- 4 8 5054B P erformance V erification Recertification.
5-1 5 T roub leshoot ing.
5- 2 85054B T roub leshooting T roubl eshooting Pr ocess Tr ou blesh oot ing Pr oc ess If y ou suspect a b ad calibr a tion, or if your netwo r k analyzer d oes not p a ss perf or mance verif i cation, follow the ste p s in Figu re 5-1 .
85054B 5-3 T roubleshooting Returning a Kit o r Device to Agilent Ret u rning a K it or Device t o Agilent If y our kit or d evice requir es service, contact Agilent T echnologies f or informati on on where to s end it. See Table 5 -1 for contact i nformation.
5- 4 85054B T roub leshooting Returni ng a Kit or Device t o Agilent.
6-1 6 R eplacea ble P arts.
6- 2 85054B Replaceab le P ar ts Int roductio n In troduct i on T able 6-1 list s the replac em ent part number s for item s included in the 85054B cali b ration kit and Fi gur e 6-1 illustrates each of t hes e it em s.
85054B 6-3 Replaceable Parts Intr oduction 20 Dis k hold er 1 5180- 8491 Gages 21 Screw-on N Gage 1 85054 -80011 22 Type-N gage set (includ es item s list ed bel ow) 1 85054 -60049 23 Type - N gage (f.
6- 4 85054B Replaceab le P ar ts Int roductio n Ta b l e 6 - 2 Replaceable P arts—Items Not Included in the Calibration Kit Ite m No. Description Qty Agilent Pa rt Numbe r Wren che s 1 1/2 in and 9/.
85054B 6-5 Replaceable Parts Intr oduction Figur e 6-1 Repl aceab le P a rts for the 850 54B C alibration Kit.
6- 6 85054B Replaceab le P ar ts Int roductio n Figure 6-2 M ore Rep lace able P a r ts for t he 8 5054B C alib ration K it.
85054B A-1 A S tand ard D efini tio ns.
A-2 85054B Standard De f initions V ersi on Changes V ersion C hanges Class a ss ignments and s tandard defini tions may c hange as more ac c urate model a nd cali b ration methods are developed. T he disk shipp ed with the kit w ill conta in the most recent v ersion.
85054B A-3 Standard Definitions Standar d Class Assignments Stan dard Clas s Assign men ts Class assig nm ent organizes c alibration s tandards i nto a format c om pa tible wit h the error models used in the measurement calibrati on.
A-4 85054B Standard De f initions Standar d Class Assignments T ab le A-2 S tandard Class Assignments for the 8 72 x Serie s N etwork Analyzer Calibration Kit L abel: [N 50 Ω ] Class A B C D E F G S.
85054B A-5 Standard Definitions Standar d Class Assignments IMPORT ANT The foll ow ing calibra tions are only s upported by c ertain PNA analy zers. See your PNA se r ies network analy zer embedded he l p system. Notes: 1. I f you are performing a TRL calibration: •S 21 T a nd S 12 T must be de fi n ed as thru stand ard s.
A-6 85054B Standard De f initions Standar d Class Assignments 4. S 11 B a n d S 11 C must be defined as the same standard . 5. S 22 B a n d S 22 C must be defined as the same standard . F or a dditional i nformation on pe r forming TRL, TRM, a nd LRM calibrati ons, r efer to your PNA series network a naly zer embedded help system.
85054B A-7 Standard Definitions Standar d Class Assignments Blank F orms The standard cl ass assignments may be changed to meet your speci fic requirements . Ta b l e A-4 throug h A-6 are provi d ed t o record the modi f ied standar d class a ssignments .
A-8 85054B Standard De f initions Standar d Class Assignments T ab le A-5 Blank F orm for the 872 x Seri e s of Network Analyz e rs Cali b ration K it Lab el: ___ _______ _______ Class A B C D E F G S.
85054B A-9 Standard Definitions Standar d Class Assignments IMPORT ANT The foll ow ing calibra tions are only s upported by c ertain PNA analy zers. See your PNA se r ies network analy zer embedded he l p system. Notes: 1. I f you are performing a TRL calibration: •S 21 T a nd S 12 T must be de fi n ed as thru stand ard s.
A-10 85054B Standard De f initions Standar d Class Assignments 4. S 11 B a n d S 11 C must be defined as the same standard . 5. S 22 B a n d S 22 C must be defined as the same standard . F or a dditional i nformation on pe r forming TRL, TRM, a nd LRM calibrati ons, r efer to your PNA series network a naly zer embedded help system.
85054B A-11 Standard Definitions Nominal Standar d Definitions Nominal Standard Definitions Standard d efinit ions provide the constants nee d ed to mathemati c ally model the electrica l characte r istics ( delay , attenua ti on, and i mpedance) of ea ch cali b ration standa r d.
A-12 85054B Standard De f initions Nominal Standar d Definit ions T able A-7 Standard Definitions for t h e 8510 Network Analyzer Sy s tem Z 0 a = 50.0 Ω Disk File Nam e : CK_NTYPB2 Calib ration K it Lab el: TYPE N B.
85054B A-13 Standard Definitions Nominal Standar d Definitions T able A-8 S tandard Definitions for the 872 x S e ries Network Analyzer Sys te m Z 0 a = 50.
A-14 85054B Standard De f initions Nominal Standar d Definit ions T able A-9 Standard Definitions for t h e PNA Series Network Analyzer Sy s tem Z 0 a = 50.
85054B A-15 Standard Definitions Nominal Standar d Definitions Blank F orms The standard d efinitions m ay be c ha nged to m eet your specif ic requirement s.
A-16 85054B Standard De f initions Nominal Standar d Definit ions T ab le A- 11 Blan k F or m fo r the 872 x S eries of Network Analyzers Sy s tem Z 0 a = 50.
85054B A-17 Standard Definitions Nominal Standar d Definitions T able A-12 Blank F orm for the PNA Series of Ne t work Analyzers Sys te m Z 0 a = _______________ Calibrati on Kit Label: __ ______ ____.
A-18 85054B Standard De f initions Nominal Standar d Definit ions.
Index 85054B Index-1 A adapt ers , 1-3 part numbers , 6-6 Agilent T echnologie s contact ing , 5- 3 alcohol isopropyl as cl eaning solvent , 3-4 altitud e , 2-2 assist ance contact ing agilent , 5-3 B.
Inde x-2 85054B Index mas ter , 3-8 , 3- 10 , 6-6 readin g , 3- 7 zeroing , 3-8 , 3- 10 gage mast er part numbe rs , 6-6 using , 3-8 , 3-10 gaging fem ale connect ors , 3-10 male co nnector s , 3-8 pr.
Index 85054B Index-3 supplies cleaning , 1-3 sys te m im peda nce , A-11 T tag se rvic e , 4-3 , 5- 3 temp erature cali bration , 2-2 devi ce , 2-2 error -correct ed temper ature range , 2-2 measu r e.
Een belangrijk punt na aankoop van elk apparaat Agilent Technologies 85054-90049 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Agilent Technologies 85054-90049 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Agilent Technologies 85054-90049 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Agilent Technologies 85054-90049 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Agilent Technologies 85054-90049 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Agilent Technologies 85054-90049 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Agilent Technologies 85054-90049 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Agilent Technologies 85054-90049 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.