Gebruiksaanwijzing /service van het product E4400-90326 van de fabrikant Agilent Technologies
Ga naar pagina of 31
Quick Start Guide Agilent T echnologies ESG F amily Signal Generators P art No. E4400-90326 Printed in USA October 2000 Supersedes April 2000 © Copyright 1999, 2000 Agilent T echnologies Serial Number Prefixes: (Affix Label Here) qsg.
Quick Start Guide iii Contents 1. Getting Started The Signal Generator at a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Creating an FM Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Start Guide 1- 1 ESG Famil y Signal Generators 1 Getting Started This chapter will help you learn how to do the following with your signal generator: • create an FM signal • generate step and list sweeps • use the save and recall functions • set up a digital modulation in GSM format (Option UN8 only) qsg.
1- 2 Quick Start Guide Getting Star ted ESG Famil y Signal Generators The Signal Generator at a Glance The Signal Generator at a Glance Refer to the figure and descriptions below as you use the procedures in this chapter . F or detailed front and rear panel information, refer to Chapter 2, “Exploring the User Interface.
Quick Start Guide 1- 3 ESG Famil y Signal Generators Getting Star ted Creating an FM Signal Creating an FM Signal This procedure will show you how to configure the signal generator to output a frequency-modulated signal with the following characteristics: • carrier frequency set to 104.
1- 4 Quick Start Guide Getting Star ted ESG Famil y Signal Generators Creating an FM Signal Setting the FM Deviation Setting the FM Rate Turning On F requency Modulation The signal generator is now configured to output a 0 dBm, frequency-modulated carrier at 104.
Quick Start Guide 1- 5 ESG Famil y Signal Generators Getting Star ted Creating a Step Sweep and a List Sweep Creating a Step Sweep and a List Sweep This section will show you two wa ys to set up the signal generator to sweep a defined set of points .
1- 6 Quick Start Guide Getting Star ted ESG Famil y Signal Generators Creating a Step Sweep and a List Sweep Turning On Continuous Step Sweep 8. Press the Ampl Stop softkey . Enter 0 using the numeric keypad and press the dBm softkey . This sets the new po wer lev el f or the end of the step sweep to 0 dBm.
Quick Start Guide 1- 7 ESG Famil y Signal Generators Getting Star ted Creating a Step Sweep and a List Sweep Configuring a List Sweep Using Step Sweep Data 1. Press the Sweep T ype List Step softkey . This toggles the Sweep T ype List Step softk ey from Step to List .
1- 8 Quick Start Guide Getting Star ted ESG Famil y Signal Generators Creating a Step Sweep and a List Sweep Turning On List Sweep for a Single Sweep 1. Press Return . This mov es the softkey men u up one lev el. Notice that the Sweep softke y is still set to sweep both frequency and amplitude data.
Quick Start Guide 1- 9 ESG Famil y Signal Generators Getting Star ted Saving and Recalling an Instrument State Saving and Recalling an Instrument State Using this procedure, you will learn how to save instrument settings to a memory register and to recall the settings .
1- 10 Quick Start Guide Getting Star ted ESG Famil y Signal Generators Saving and Recalling an Instrument State Saving an Instrument State Recalling an Instrument State 1. Press Save followed by the Select Seq softkey . The sequence number becomes the activ e function.
Quick Start Guide 1- 11 ESG Famil y Signal Generators Getting Star ted Setting Up a Digital Modulation in the GSM Format Setting Up a Digital Modulation in the GSM F ormat NO TE Y ou must have an ESG-D or ESG-DP Series Signal Generator with Option UN8 to perform this procedure.
1- 12 Quick Start Guide Getting Star ted ESG Famil y Signal Generators Setting Up a Digital Modulation in the GSM Format Selecting the Data F ormat Setting Up Timeslot 0 1. Press Mode . Then press the following softkeys: Real Time I/Q Baseband (if it appears) > TDMA > GSM .
Quick Start Guide 1- 13 ESG Famil y Signal Generators Getting Star ted Setting Up a Digital Modulation in the GSM Format Setting Up Timeslot 7 6. Press the FIX4 softkey . This changes the transmitted data to a fix ed 4-bit repeating sequence. The def ault 4-bit repeating sequence of 0000 is shown in the activ e entr y area of the display .
1- 14 Quick Start Guide Getting Star ted ESG Famil y Signal Generators Setting Up a Digital Modulation in the GSM Format Turning On the GSM F ormat and the Modulation The signal generator is now configured to burst two uplink timeslots with a − 5.0 dBm, GMSK digitally modulated carrier at 891 MHz.
Quick Start Guide 2- 1 ESG Famil y Signal Generators 2 Exploring the User Interface This chapter provides you with an overview of your signal generator’ s user interfaces: • front panel hardkeys and connectors • display fields and annotations • rear panel connectors qsg.
2- 2 Quick Start Guide Exploring the User Interface ESG Famil y Signal Generators Front P anel F ront P anel The following pages describe the numbered items shown in the figure below .
Quick Start Guide 2- 3 ESG Famil y Signal Generators Exploring the User Interface Front P anel 1. EXT 1 INPUT This female BNC input connector accepts a 1-V pk signal for FM, Φ M, and AM. 2. EXT 2 INPUT This female BNC input connector accepts a 1-V pk signal for FM, Φ M, AM, and pulse modulation.
2- 4 Quick Start Guide Exploring the User Interface ESG Famil y Signal Generators Front P anel 11. Return The Return key cancels the current active function and moves you from your current softkey menu to the softkey menu that precedes it.
Quick Start Guide 2- 5 ESG Famil y Signal Generators Exploring the User Interface Front P anel 21. Display The LCD displa y provides information on the current instrument state such as modulation status , frequency and amplitude settings, status indicators , and error messages.
2- 6 Quick Start Guide Exploring the User Interface ESG Famil y Signal Generators Front P anel 30. Recall This hardkey lets you restore any instrument state that you previously saved in a memory register . Y ou can save up to 100 different instrument states in a combination of 100 memory registers and 10 register sequences.
Quick Start Guide 2- 7 ESG Famil y Signal Generators Exploring the User Interface Display Display The following pages describe the numbered items shown in the figure below . 1. Frequency Area The current CW frequency setting is shown in this portion of the display .
2- 8 Quick Start Guide Exploring the User Interface ESG Famil y Signal Generators Display 4. Error Messages Area Abbreviated error messages are reported in this space. When multiple error messages occur , only the most recent message remains displayed.
Quick Start Guide 2- 9 ESG Famil y Signal Generators Exploring the User Interface Display ENVLP This annunciator appears if the burst envelope modulation is turned on. This annunciator is present only on ESG-D and ESG-DP Series Signal Generators. ERR This annunciator appears when an error message is placed in the error queue.
2- 10 Quick Start Guide Exploring the User Interface ESG Famil y Signal Generators Display RF OFF This annunciator toggles between RF OFF and RF ON and is alwa ys visible in the display . This annunciator indicates whether the RF signal is present at the RF OUTPUT connector .
Quick Start Guide 2- 11 ESG Famil y Signal Generators Exploring the User Interface Rear Panel Rear P anel The following pages describe the numbered items shown in the figure below . 1. AC P ower Receptacle The power cord receptacle accepts a three-pronged cable that is shipped with the instrument.
2- 12 Quick Start Guide Exploring the User Interface ESG Famil y Signal Generators Rear Panel 4. AUXILIARY INTERFACE This male DB-9 connector is an RS-232 serial port that can be used for controlling the signal generator remotely . It is functionally equivalent to the GPIB connector .
Quick Start Guide 2- 13 ESG Famil y Signal Generators Exploring the User Interface Rear Panel 12. P A TTERN TRIG IN This input can accept either a TTL/CMOS low to TTL/CMOS high or TTL/CMOS high to TTL/CMOS low edge trigger .
2- 14 Quick Start Guide Exploring the User Interface ESG Famil y Signal Generators Rear Panel 18. BASEBAND GEN REF IN With Option UN8 enabled, the B ASEBAND GEN REF IN connector accepts a 0 to +20 dBm sinewa ve or TTL squarewave signal from an external 13-MHz timebase reference.
Quick Start Guide 2- 15 ESG Famil y Signal Generators Exploring the User Interface Rear Panel 26. BER DA T A IN Use this connector to input the data streams for the bit-error -rate measurements . This female BNC connector is present only on instruments with Option UN7.
Een belangrijk punt na aankoop van elk apparaat Agilent Technologies E4400-90326 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Agilent Technologies E4400-90326 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Agilent Technologies E4400-90326 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Agilent Technologies E4400-90326 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Agilent Technologies E4400-90326 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Agilent Technologies E4400-90326 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Agilent Technologies E4400-90326 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Agilent Technologies E4400-90326 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.