A TM M ultimode Fiber Transceivers for SONET OC-3/SDH STM-1 in Low Cost 1x9 P ackage Style T echnical Data Features • Full Compliance with ATM Forum UNI SONET OC-3 Multimode Fiber Physical Layer Spe.
2 design complies with the maximum height allowed for the duplex SC connector over the entire length of the package. The optical subassemblies utilize a high volume assembly process together with low cost lens elements which result in a cost effective building block.
3 DATA OUT SIGNAL DETECT OUT DATA IN ELECTRICAL SUBASSEMBLY QUANTIZER IC DRIVER IC TOP VIEW PIN PHOTODIODE DUPLEX ST RECEPTACLE OPTICAL SUBASSEMBLIES LED PREAMP IC DIFFERENTIAL SINGLE-ENDED DIFFERENTIAL Figure 2. Package Outline Drawing. Figure 1a.
4 Figure 3. Pin Out Diagram. 25.4 (1.000) MAX. 24.8 (0.976) 42 (1.654) MAX. 5.99 (0.236) 12.7 (0.500) 12.0 (0.471) MAX. 0.5 (0.020) 3.3 ± 0.38 (0.130) (± 0.015) + 0.08 - 0.05 + 0.003 - 0.002 + 0.25 - 0.05 + 0.010 - 0.
5 Agilent LED technology has produced 800 nm LED and 1300 nm LED devices with lower aging characteristics than normally associated with these technolo- gies in the industry. The industry convention is 3 dB aging for 800 nm and 1.5 dB aging for 1300 nm LEDs.
6 Figure 5. Transceiver Relative Optical Power Budget at Constant BER vs. Signaling Rate. Figure 6. Bit Error Rate vs. Relative Receiver Input Optical Power. illustrates the typical trade-off between link BER and the receivers input optical power level.
7 NO INTERNAL CONNECTION NO INTERNAL CONNECTION HFBR-520X TOP VIEW V EE RD RD SD V CC V CC TD TD V EE 123456789 C1 C2 L1 L2 R2 R3 R1 R4 C5 C3 C4 R9 R10 V CC FILTER AT V CC PINS TRANSCEIVE.
8 Board Layout - Art W ork The Applications Engineering group is developing Gerber file art work for a multilayer printed circuit board layout incorporating the recommendations above.
9 Electromagnetic Interference (EMI) Most equipment designs utilizing these high speed transceivers from Agilent will be required to meet the requirements of FCC in the United States, CENELEC EN55022 (CISPR 22) in Europe and VCCI in Japan.
10 Figure 10. Relative Input Optical Power vs. Eye Sampling Time Position. Figure 9. Transmitter Output Optical Spectral Width (FWHM) vs. Transmitter Output Optical Center Wavelength and Rise/Fall Times.
11 Transceiver Reliability and Performance Qualification Data The 1 x 9 transceivers have passed Agilent reliability and performance qualification testing and are undergoing ongoing quality monitoring. Details are available from your Agilent sales representative.
12 HFBR-5203, -5204, and -5205 Series Recommended Operating Conditions Parameter Symbol Min. Typ. Max. Unit Reference Ambient Operating Temperature T A 07 0 ° C Supply Voltage V CC 4.75 5.25 V Data Input Voltage - Low V IL - V CC -1.810 -1.475 V Data Input Voltage - High V IH - V CC -1.
13 HFBR-5203, -5204 and -5205 Series Transmitter Electrical Characteristics (T A = 0 ° C to 70 ° C, V CC = 4.75 V to 5.25 V) Parameter Symbol Min. Typ.
14 Agilent offers two such compatible duplex Push-Pull ST connectored jumper cable assemblies to assist you in your evaluation of these products. These cables may be purchased from Agilent with the following part numbers. 1. HFBR-XXX001 A duplex cable 1 meter long assembled with 62.
15 HFBR-5203/-5203T Receiver Optical and Electrical Characteristics (T A = 0 ° C to 70 ° C, V CC = 4.75 V to 5.25 V) Parameter Symbol Min. Typ. Max. Unit Reference Input Optical Power P IN Min. (W) -26 dBm avg. Note 16 Minimum at Window Edge Output Optical Power P IN Min.
16 HFBR-5204/-5204T Receiver Optical and Electrical Characteristics (T A = 0 ° C to 70 ° C, V CC = 4.75 V to 5.25 V) Parameter Symbol Min. Typ. Max. Unit Reference Input Optical Power P IN Min. (W) -29 dBm avg. Note 16 Minimum at Window Edge Figure 10 Input Optical Power P IN Min.
17 HFBR-5205/-5205T Transmitter Optical Characteristics (T A = 0 ° C to 70 ° C, V CC = 4.75 V to 5.25 V) Parameter Symbol Min. Typ. Max. Unit Reference Output Optical Power BOL P O -19 -14 dBm avg. Note 9 62.5/125 µ m, NA = 0.275 Fiber EOL -20 Output Optical Power BOL P O -22.
18 HFBR-5205/-5205T Receiver Optical and Electrical Characteristics (T A = 0 ° C to 70 ° C, V CC = 4.75 V to 5.25 V) Parameter Symbol Min. Typ. Max. Unit Reference Input Optical Power P IN Min. (W) -30 dBm avg. Note 16 Minimum at Window Edge Figure 10 Input Optical Power P IN Min.
19 expressed as a percentage. With the transmitter driven by a 25 MBd (12.5 MHz square-wave) input signal, the average optical power is measured. The data “1” peak power is then calculated by adding 3dB to the measured average optical power.
www.semiconductor.agilent.com Data subject to change. Copyright © 1999 Agilent Technologies, Inc. Obsoletes 5963-5774E (2/95) 5965-9729E (11/99).
Een belangrijk punt na aankoop van elk apparaat Agilent Technologies HFBR 5203 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Agilent Technologies HFBR 5203 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Agilent Technologies HFBR 5203 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Agilent Technologies HFBR 5203 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Agilent Technologies HFBR 5203 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Agilent Technologies HFBR 5203 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Agilent Technologies HFBR 5203 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Agilent Technologies HFBR 5203 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.