Gebruiksaanwijzing /service van het product CP2E van de fabrikant Crestron electronic
Ga naar pagina of 40
.
This document was prepared and written by th e Technical Docum entation department at: Crestron Electronics, Inc. 15 Volvo D rive Rockleigh, NJ 076 47 1-888-CRESTRON.
Crestron CP2/CP2E 2-Series Integrated Control Processor Contents 2-Series Integrated Control Processor: CP2/CP2E 1 Introduc tion ................................................................................................................... ......
.
Crestron CP2/CP2E 2-Series Integrated Control Processor 2-Series Integrated Control Processor: CP2/CP2E Introduction Features and Functions Crestron’s CP2 and CP2E 2-Series Integrated Con trol Proce.
2-Series Integrated Control Processor Crestron CP2/CP2E bit Motorola ColdFire processor. The 2-Series operating system is vastly upgraded from Crest ron’s X-gene ration pro ducts, yet compatible with existing Crestron software and programm ing.
Crestron CP2/CP2E 2-Series Integrated Control Processor Physical Description The CP2/CP2E integrated control systems are housed in black enclos ures with labeling on t he front an d rear panels . The front panels of b oth units i nclude standar d LEDs and two reset buttons.
2-Series Integrated Control Processor Crestron CP2/CP2E Controls and Indicators The CP2/CP2E front panel indicators a nd controls a re described bel ow. PWR (Power) This LED illuminates when the unit is co nnected to and receives 24VDC power from an AC power pack or the C resnet NET connector.
Crestron CP2/CP2E 2-Series Integrated Control Processor NOTE: The orientation of this connector is “upside down” co mpared to other Crestron networ k devices (e.g., CNX-BI PAD8, CNX-RMCLV). Be sure the mating Cresnet cable connector is pr operly aligned before attempting to insert it, to avoid damage to the CP2/C P2E unit .
2-Series Integrated Control Processor Crestron CP2/CP2E COM Pinout to RS-485 Bus COM ( DB9) CO NNECT O R RS-485 BUS T ie Pins 1 & 9 - T ie Pins 4 & 6 + Pin 5 G INFRARED – SERIAL OU TPUT A B C D E F G H S G S G S G S G INFRA RED - SERIAL OUTPUT S G S G S G S G These connectors provi de eight serial outp uts for IR or serial int erface.
Crestron CP2/CP2E 2-Series Integrated Control Processor 24VDC, 2.0A (Power Supply) 24VDC 2.0A This male connector can be used to supply 24 VDC power to the CP2/CP2E from an AC power pac k purchased se parately. (Re fer to O ptional Powe r Supply on page 1 3).
2-Series Integrated Control Processor Crestron CP2/CP2E series control engine. Non-vo latile memory c ontains information that is retained after loss of electrical power. Volatile memory is lost after a power failure. Refer to the lists below for a breakdown of memory usage for program-related information stored in the unit.
Crestron CP2/CP2E 2-Series Integrated Control Processor DRAM DRAM is use d by the ope rating system for dynam ic storage of variables, si gnals and other const ructs use d at runti me. The actua l amount of DR AM used at a ny given time depends on the particular program that is running , i.
2-Series Integrated Control Processor Crestron CP2/CP2E Ear Attachment for Rack Mounting (CP2E shown in illustration) 1. Using a Phillips screwdriver, remove and retain the three side screws closest to the fr ont panel.
Crestron CP2/CP2E 2-Series Integrated Control Processor 5. Secure the wires connected to the te rm inal block with a ti e wrap around the bussing stri p to provi de strain reli ef. Network Wiring NOTE: When making wire connections, refer to the latest revision of the Cresnet Network Inte rconnect Dra wing (Doc.
2-Series Integrated Control Processor Crestron CP2/CP2E Wire Gauge Values RESISTANCE (R) WIRE GAUGE 4 16 6 18 10 20 15 22 13 Doubled CAT 5 8.7 Tripled CAT5 NOTE: When dais y-chaining Cresnet unit s, stri p the ends of the wires carefully to avoid nicking the condu ctors.
Crestron CP2/CP2E 2-Series Integrated Control Processor Optional Power Supply The units ca n be powe red through t he NET netw ork conne ctor, or by an optional AC power p ack (pur chased separa tely).
2-Series Integrated Control Processor Crestron CP2/CP2E Slot 1: C2Net-Device The C2Net-De vice slot ena bles the CP2 an d CP2E to c ontrol up t o 252 Cr esnet devices. Each Cresnet de vice is assigned a unique identifier called a Net ID, which is a hexadecim al value rangi ng from 03 to FE.
Crestron CP2/CP2E 2-Series Integrated Control Processor Slot 3: C2I-IO8 The CP2 and C P2E pro vide eight I/O ports c alled Ve rsiports, eac h of whi ch can function as a digital i nput, a di gital out put, or an a nalog in put. Each Versi port has a correspondin g pullup resistor.
2-Series Integrated Control Processor Crestron CP2/CP2E Driving the correspondi ng <pu-disabl e> signal hi gh can modi fy this beha vior. This i s not recommended, though , since it will cause the output pin to float when < o > goes low. Example 1 (rec ommended): The < pu-disable1 > signal is driven low or left undefined.
Crestron CP2/CP2E 2-Series Integrated Control Processor A voltage source is pl aced on Ve rsiport 1 a nd < MinChange1 > is set t o 10 via an Analog Initialize symbol. The value of < i1 > will not be propag ated until it changes by at least 10.
2-Series Integrated Control Processor Crestron CP2/CP2E 3. When all t he IP IDs and ass ociated IP ad dresses have been adde d to the IP Table, click Send IP Table to Contr ol System .
Crestron CP2/CP2E 2-Series Integrated Control Processor If the program contains S IMPL+ or User modules , the conversion might generate error messages. This is because m odules and programs often c ontain symbols with “ambiguous” s ignals. F or exam pl e, the inputs of the Serial to Analog sym bol can be defined as eith er analog or serial.
2-Series Integrated Control Processor Crestron CP2/CP2E Module Header Information After you convert each module in a prog ram, you can convert the program as described pre viously: dra g the CP2 or CP2E ont o the exis ting cont rol syst em in System Views and click Yes to confirm the re placement.
Crestron CP2/CP2E 2-Series Integrated Control Processor • Hardware ha ndshaking (R TS/CTS) e nabled. • Software ha ndshaki ng (XON/ XOFF) not e nabled. “Port Settings” dialog box: Default PC se ttings for RS-232 co mmunication with the CP2/CP2E.
2-Series Integrated Control Processor Crestron CP2/CP2E use a CAT5 cr ossover cabl e to connect th e two LAN ports directly, without using a hub. Once the cable connections are made, ope n the Crest ron Viewpo rt and clic k Setup | Communication Settings on the m enu to di splay the “Po rt Settings” di alog bo x.
Crestron CP2/CP2E 2-Series Integrated Control Processor some ma y be internal (e. g., for a m odem). Cons ult the m anufacture r’s documentation for fur ther information about th e COM ports on your PC. 3. Check the ERR LED indicat or on the f ront panel of the CP 2/CP2E.
2-Series Integrated Control Processor Crestron CP2/CP2E Compiling and Uploading a Program to the Control System After you have completed your SI MPL Windows program you must compile and upload the program to the control system.
Crestron CP2/CP2E 2-Series Integrated Control Processor Another way to verify t hat the program has been tra nsferred successfully is to select Report Program Information on the View port Functions menu. Prog ram information is also disp layed in the View port console whenever power is removed and re-applied to the CP2/CP2E.
2-Series Integrated Control Processor Crestron CP2/CP2E Uploading Touchpanel Pr ojects via the CP2/CP2E You can use a connection t o the CP2 or CP2E to upload Visi onTools Pro- e projects to any Cresnet touchpa nel. Com piled projects f or TPS pane ls are contai ned in V TZ files; project s for all othe r touchpa nels are cont ained in HEX files.
Crestron CP2/CP2E 2-Series Integrated Control Processor 3. After the transfer is complete, the CP2/CP2E will automatically reboot. To confirm the tr ansfer , click Diagnostics | Check Ops Version . The Viewport c onsole sho uld disp lay the new .c uz versi on num ber.
2-Series Integrated Control Processor Crestron CP2/CP2E Troubleshooting The table belo w and on t he next page provides cor rective action fo r possible trouble situations. If further assistance is requi red, please contact a Crestron cust omer service representative.
Crestron CP2/CP2E 2-Series Integrated Control Processor Battery Replacement A Lithium battery is used to power the system clock within the CP2/CP2E. Under normal conditions, it will last for approximately 10 years. In the event that the clock fails, only an authorized technician sh ould replace it.
2-Series Integrated Control Processor Crestron CP2/CP2E Passthrough Mode Dialog Box The PC will now be communicating directly with th e device. To exit Passthr ough mode, simply cl ick Functions | Exit Passthr ough Mode . A system reboot will also exit Passthrough mode.
Crestron CP2/CP2E 2-Series Integrated Control Processor Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information or have questions , please take a dvantage of.
2-Series Integrated Control Processor Crestron CP2/CP2E Software License Agreement This License Agreement (“Agree ment”) is a legal contract betw een you (either an individual or a single business entit y) and Crestron Electronics, Inc.
Crestron CP2/CP2E 2-Series Integrated Control Processor If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully.
2-Series Integrated Control Processor Crestron CP2/CP2E Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchan dise may be retur ned for cr edit, exchan ge, or service without prior authorization from CR ESTRON.
Crestron CP2/CP2E 2-Series Integrated Control Processor This page intentionally left blank . Operations Guide - DOC. 5980 2-Series Integrated Control Processo r: CP2/CP2E • 35.
Crestron Electronics, Inc. Operations Guide – DOC. 5980 15 Volvo Drive Rockleigh, NJ 07647 02.02 Tel: 888.CRESTRON Fax: 201.767.7576 Specifications subject to www.
Een belangrijk punt na aankoop van elk apparaat Crestron electronic CP2E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Crestron electronic CP2E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Crestron electronic CP2E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Crestron electronic CP2E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Crestron electronic CP2E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Crestron electronic CP2E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Crestron electronic CP2E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Crestron electronic CP2E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.