3M Pers onal Safet y Di vision 3M TM EVM Series Environmental Monitor EVM Series Quick Start Guide.
EVM and User Interface Display Backlight Particulate pump Left arrow key Run/Stop key Indicators Softkey menus Up arrow key Altf key Enter key Right arrow key Down arrow key On/Off and Esc key T urning On/Off and Navigating 1. Press key power on. (Following a splash/welcome screen, the Start screen will appear .
Overview of running measurements Quick Help List: typical gas, particulates,or air quality measuring overview 1. T urn the EVM on and check the battery power . 2. Reset/Clear memory , if necessary ( StartFile System menu). • This will clear out data history before your logging begins to ensure you havesufcientmemoryspace.
Particulate Zero Calibration Priortocalibrating,ensuretheimpactorsarewell-greasedwithanappliedthin-lmofsilicone grease. (Please see “Impactor Care” on page 10 or EVM series user manual.) 1. Attach the Zero/HEP A lterandtubingintotheturret.
Volatile Or ganic Compounds (VOCs) VOCs, air pollution with carbon-containing chemicals, are measured using a Photoionization detector 10.6eV . The EVM is equipped to notify you when maintenance and cleaning is required for the PID sensor .
T oxic Gases The following toxic gases table displays a quick overview of the ranges and the gases needed to perform zero and span calibrations. T ype of Gas Range Res. Zero cal gas Span cal gas Carbon Monoxide (CO) 0 -1000 ppm 1 ppm nitrogen/pure air CO Chlorine (CL 2 ) 0.
T oxic and Carbon Dioxide Span Calibration T operformaspancalibrationwithaspecictoxicgas,pleasereferencethetoxicgas table. For the CO 2 span calibration, the range (or span) should be a sizeable fraction of the selected full scale range of the gas.
T emperature and Relative Humidity Logging/Viewing T emperature and/or Rela tive Humidity The T emperature and Relative Humidity readings are viewable in either the T emp-RH measurement screen or in the Composite screen.
Air Velocity T o view air velocity measurements, perform or verify the following: 1. The air velocity probe is enabled in SetupAUXAir V elocity screen. 2. Connect the air velocity probe and attachment to the EVM unit to the auxiliary Air probe inlet. (See Air Probe inlets diagram in previous section, “Particulate Air Flow”.
Maintenance/Cleaning Sensors Locations The gas sensors are inserted, factory calibrated, and ready for usage upon delivery . (The diagram below is based on the EVM-7 model.) Occasionally , you may have to care for the sensors which will require removing and inserting.
Working with 3M TM Detection Management Softw are DMS Communicating 1. When the EVM is On , plug the USB cable into the EVM and plug the opposite end to the USB port of your computer .
Personal Safety Division 3M Detection Solutions ISO 9001 Registered Company ISO 17025 Accredited Calibration Lab 1060 Corporate Center Drive Oconomowoc, WI 53066 Customer Service: 262-567 -9157 T oll Free: 800-245-0779 ww w.3M.com/detection 3M i s a tr ade ma rk o f 3M C om pany, used under license in Canada.
Een belangrijk punt na aankoop van elk apparaat 3M 3MTM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen 3M 3MTM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens 3M 3MTM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding 3M 3MTM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over 3M 3MTM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van 3M 3MTM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de 3M 3MTM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met 3M 3MTM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.