Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, and keep it in a safe place for future reference. Also read the SETTING MANUAL and OPERA TION MANUAL on the bundled CD-ROM.
2 CONTENTS PRECAUTIONS ................................ 3 W ARNING ....................................... 3 CAUTION ........................................ 3 GENERAL PRECAUTIONS ............ 3 Notes on using this system .......... 4 Notices ........
3 PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to W ater General Precautions W ARNING Negligence could result in death or serious injury . 1. Do not dismantle or alter the unit. Fire or electric shock could result.
4 SYSTEM CONFIGURA TIONS The IS system is a commercial and security video intercom system especially designed for applications in facilities such as of fi ce buildings, factories, schools, hospitals, and prisons.
5 System con fi guration examples ■ Standard (IP) system The following is an example of standard (IP) system for controlling security and communication for facilities. A site must be con fi gured with an IP-based system. • A standard (IP) system can consist of local systems and IP units.
6 CONNECTIONS System connection diagram The following is an example of standard (IP) system connection diagram. Refer to page 9 to 26 for details about each unit connection.
7 IP IP IS-IPC* 1 IS-RCU IS-RS IS-IPMV IS-IPDV /IS-IPDVF IP PT IS-SS IP PS-2420/D/UL/S* 2 PS-2420/D/UL/S* 2 IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S PoE PoE AC transformer Maximum number of each unit connectable to a "local system" and a site of "standard (IP) system" Category Model name T ype Max.
8 Cables Cables and connectors are not included with the products. Refer to page 9 to 26 for details about each unit connection. Notes on cables Pair4 Pair3 12345678 12345678 Pair2 Pair1 T568A Pair4 Pair2 Pair3 Pair1 T568B How to connect or disconnect stranded wires.
9 UNIT DET AILS Control unit common information The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS- * RCU) and IP control unit (IS-IPC).
10 Central control unit ( IS-CCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Central control unit (IS-CCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max.
11 ■ Connections 1CX1 1CX2 M1 M2 1MX1 1MX2 1MX3 2MX1 2MX2 2MX3 M3 M4 D1 D2 IP1 LAN IP2 IP3 D3 D4 2CX1 2CX2 3CX1 3CX2 4CX1 4CX2 P1 P2 P3 P4 L1 L2 L3 L4 L5 L6 L7 L8 S1 E S2 E S3 E S4 E IS-RCU MASTER S.
12 Add-on control unit ( IS-SCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Add-on control unit (IS-SCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.
13 ■ Connections M1 M2 M3 M4 M5 M6 M7 M8 D1 D2 MX1 MX3 ID 1 2 MX2 D3 D4 D5 D6 D7 D8 P1 P2 P3 P4 L1 L2 L3 L4 MASTER ST ATION IS-CCU DC48V VIDEO/AUDIO DOOR/SUB ST ATION P A OUTPUT (600 Ω ) VIDEO OUTPUT CONT ACT OUTPUT (AC/DC24V 0.
14 Room sub control unit ( IS-RCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Room sub control unit (IS-RCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max.
15 ■ Connections C1 C2 CX1/IP1 ID 1 2 3 4 CX2/IP2 C3 C4 C5 C6 C7 C8 C9 C10 C1 1 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 C30 P1 P2 P3 P4 L1 L2 L3 L4 IS-CCU/ IS-IPC DC48V AUDIO DOOR/SUB ST ATION P A OUTPUT (600 Ω ) CONT ACT OUTPUT (AC/DC24V 0.
16 IP control unit ( IS-IPC ) IP : This unit is needed to connect a local system to a standard (IP) system. ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations IP control unit (IS-IPC) Power source 48V DC (supplied from the power supply unit) Current consumption Max.
17 ■ Connections IP1 IP2 IP3 LAN IS-RCU IS-CCU DC48V ETHERNET CO TELEPHONE 10m (33') 10m (33') 15m (50') 2C IP1 IP2 IP3 φ 0.8-1.2mm (20-16 AWG) IP1 IP2 IP3 IS-RCU IS-CCU CA T5e/6 (x3.
18 Color monitor master station (IS-MV) For the part names and their functions, see the OPERA TION MANUAL. * ■ Accessories ・ Mounting bracket × 1 ・ Name card × 1 ・ Desktop stand × 1 ・ Scr.
19 When mounting on a desktop stand 30 r 45 r 60 r ■ Connections M V V A A VIDEO OUTPUT AUDIO OUTPUT M1 M4 CA T5e/6 Coax 2C M1 M8 CA T5e/6 P NP NTSC NO TES: Do not use the unoccupied terminals and ports for other purposes.
20 V andal-resistant video door station (IS-DV , IS-DVF), V andal-resistant audio door station (IS-SS) ■ Accessories ・ Screw (for wall-mounting) × 4 (IS-DV only) ・ Special screwdriver × 1 ・ .
21 ■ Mounting IS-DV (surface-mount) ABCDEFG IS-DVF ( fl ush-mount), IS-SS ( fl ush-mount) e.g.) IS-DVF Special screwdriver (included) Loosen T ighten V andal-resistant front panel 81 mm (3-1/4'') 194 mm (7-1 1/16'') W ater escape holes Do not block the holes.
22 ■ Connections (IS-DV and IS-DVF) D NO COM NC PT 300m (980') D1 D4 CA T5e/6 300m (980') D1 D8 CA T5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.
23 ■ Connections (IS-SS) D NC COM NO PT 300m (980') D1 D4 CA T5e/6 300m (980') D1 D8 CA T5e/6 300m (980') C1 C30 CA T5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.
24 Room sub station (IS-RS) ■ Accessories ・ Mounting bracket × 1 ・ Screw (for gang box) × 2 ・ Screw (for wall-mounting) × 2 ・ China RoHS paper × 1 ・ Tie-wrap × 1 ■ Mounting <Back wiring> <Surface wiring> When a 1-gang box is not mounted, the cable and wires can be routed to the top of the unit.
25 ■ Connections C SP SP S SE NO COM P AGING CONT ACT IN CONT ACT OUT 150m (490') D1 D4 CA T5e/6 150m (490') D1 D8 CA T5e/6 150m (490') C1 C30 CA T5e/6 2C 2C P NP 2C φ 0.65-1.2mm (22-16 AWG) 15m (50') φ 0.65-1.2mm (22-16 AWG) 15m (50') φ 0.
26 Power supply unit (IS-PU-UL and IS-PU-S) ■ Accessories ・ AC cord × 1 (included in the package of this power supply unit) ・ Precaution & mounting instruction sheet (paper) × 1 ・ China .
27 TECHNICAL DA T A AND PRECAUTIONS T echnical data Operating temperature: • Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC), Master station (IS-MV), Room sub station (IS-RS), Power supply unit (IS-PU.
AIPHONE CO., LTD., NAGOYA, JAPAN AIPHONE CORPORATION, BELLEVUE, WA, USA AIPHONE S.A.S., LISSES-EVRY, FRANCE http://www.aiphone.net/ W ARRANTY Aiphone warrants its products to be free from defects of m.
Een belangrijk punt na aankoop van elk apparaat Aiphone 834168 C P0811JZ (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Aiphone 834168 C P0811JZ heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Aiphone 834168 C P0811JZ vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Aiphone 834168 C P0811JZ leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Aiphone 834168 C P0811JZ krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Aiphone 834168 C P0811JZ bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Aiphone 834168 C P0811JZ kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Aiphone 834168 C P0811JZ . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.