Gebruiksaanwijzing /service van het product GH series van de fabrikant Aiphone
Ga naar pagina of 47
- 1 - 1105 A GH SERIES Apar tment Inter com System INSTALLATION &OPERATION MANUAL.
- 2 - General Prohibitions General Precautions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water W ARNING (Negligence could result in death or serious injur y to people) 1. The unit must be installed and wired by a qualified technician.
- 3 - 1 SYSTEM CONFIGURA TIONS Standard System Configuration Diagram 6 Expanded System Configuration Diagram 8 W iring Distance 9 2 UNIT Unit (Entrance Station) 10 Combination Example for Entrance Sta.
- 4 - Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation 1P Entrance No . 2 to 5 T r unk line No . 3 to 6 Door release Entrance station Security guard station 1P(Audio) 1P(Video) 1P GH-BC GH-MK GH-VBC 1Px2 T r unk line No .
- 5 - Light Orange Orange White Blue GH-4Z B1 B2 R1 R2 B1 B2 R1 R2 B1 B2 R1 R2 B1 B2 R1 R2 B1 B2 R1 R2 OUT 3 OUT 4 B1 B2 R1 R2 B1 B2 R1 R2 OUT 1 LINE OUT LINE IN OUT 2 B A GH-4Z B A B A 1Px2 1Px2 1Px2 1Px2 1Px2 Doorbell Doorbell Divided cabling with GH-4Z T r unk line No .
- 6 - 1 SYSTEM CONFIGURA TIONS GH-D A + GH-SW GH-D A + GH-NS, GH-10K GH-V A + GH-D A + GH-SW GH-V A + GH-D A + GH-NS, GH-10K GH-BC GH-VBC 2 B A C 1 3 E D F 5 K J L 4 H G I 6 N M O 8 U T V 7 R Q P S Y X W Z 9 0 GH-MK Max.
- 7 - 1-1 Standard System Configuration Dia gram (1) Audio signal line (2) V ideo signal line (3) Power supply line a. Entrance station (For details, see 2-1 and 2-2) [1] V ideo/audio + digital name s.
- 8 - GH-V A + GH-D A + GH-NS, GH-10K GH-MK Max. 8 (3 per trunk) Max. 2 GH-V A GH-V A GH-1KD / GH-4Z a e 1-2 #2 #3 #4 #2 #3 #4 (1) (2) (3) :A :V :P 12 #1 #2 #1 #2 #3 #4 [1] a e a e f GH-BC GH-BC 2 B A.
- 9 - 1-2 Expanded System Configuration Diagram 1. Common trunk line #1, 2 2. Sub trunk line #1 - 4 Sub trunk line #2 - #4 are the same as #1. Maximum 125 units per sub trunk line. (1) Audio signal line (2) V ideo signal line (3) Power supply line a. Entrance station (For details, see 2-1 and 2-2) b .
- 10 - 2 UNIT 2-1 Unit (Entrance Station) [1] Speech module panel GH-DP [2] Speech module GH-D A [3] Camera module panel GF-VP [4] Camera module GH-V A [5] 1-call button panel GF-1P [6] 2-call button .
- 11 - 2-2 2-3 Combination Example for Entrance Station 1. Audio only . Direct selection (8 stations). 2. V ideo/audio. Direct selection (8 stations). 3.
- 12 - 2-5 Security Guard Station [1] Security guard station GH-MK [2] Mounting screws (enclosed with GH-MK) [3] RS-232C cable (enclosed with GH-MK) 2-4 Residential Station [1] Audio residential stati.
- 13 - Mounting the Entrance Station (1) [1] Back box [2] Joint pipe [3] Back box assembly dimensions [4] Special screwdri ver (enclosed with GH-BC) 1. Mounting the back box • Make a hole for the cable. • Use the joint pipe to assemble the back box.
- 14 - 3-2 3-3 Mounting the Entrance Station (3) 1. Example of interconnection of modules. 2. Use GF-C to connect to the name scrolling module. 3. T o position the speech module in the center row , run GF-C through the joint pipe in adv ance. Mounting the Entrance Station (2) 1.
- 15 - 3-4 Bus Control Unit and P ower Supply Adapter [1] Din rail (W -DIN11) [2] Screw hole [3] POWER switch [4] Power On LED (green) [5] Lock release lever [6] W all mounting screws (x2) 1. Mount GH-BC and GH-VBC to the Din rail. Click unit into place.
- 16 - 3-5 3-6 Residential Station [1] Mounting scre ws (x2) [2] Mounting bracket [3] 1-gang box or round back box [4] T erminal block (GH-1AD, GH-1KD) 1. Mount the mounting bracket on the 1-gang box. 2. Connect the wiring to the terminal block. 3. Mount the station unit to the mounting bracket.
- 17 - Security Guard Station (Desk-top Mounting Using the GFW -S Stand) [1] Screws enclosed with GFW -S (x4) [2] Tie wrap enclosed with GFW -S 1. Separate the mounting bracket and the protecti ve co ver from the back of the unit. 2. Mount the mounting bracket to GFW -S as shown in the drawing.
- 18 - 4 WIRING IN1 IN2 IN3 IN4 IN5 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 + – GH-VBC IN1 IN2 IN3 IN4 IN5 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 A1 A2.
- 19 - 4-1 4-2 Standard System (1) [1] Entrance Station [2] Door release timer (set to "M" at time of shipment) • Set the duration for the door release function when the door release button is pressed. [0.5] - [20]: 0.5 secs - 20 secs [20] - [M]: Activ ates while the b utton is pressed.
- 20 - SW1 A B IN OUT R1 R2 R1 R2 C 0.65 10 9 CE K KE Do not remove the wires (For end users) 4-3 [2] [1] [5] GH-1KD GH-1KD GH-4Z GH-4Z d GH-VBC GH-BC b SW1 B A SW1 B A SW1 B A SW1 B A 1P NP 1P NP 1P .
- 21 - 4-3 Standard System (2) Homerun Wiring [1] 4-way video junction unit GH-4Z • For the terminating GH-4Z (maximum of 6 units per trunk), set the setting switch to "A". [2] Residential station GH-1KD, GH-1AD, GH-1MD • For GH-1KD and GH-1AD, set the setting switch to "A".
- 22 - GH-VBX A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 B1 B2 B1 B2 B1 B2 B1 CN2 B2 COMMON1 COMMON2 SUB1 SUB2 IN1 IN2 IN3 IN4 IN5 OUT1 OUT2 OUT3 O.
- 23 - 4-4 Expanded System 1. Common trunk line: maximum of 2 trunk lines 2. Sub trunk line: maximum of 4 trunk lines Maximum of 125 units (maximum of 48 units for standard system) • The wiring of the sub trunk line is the same as the standard system.
- 24 - 6-1 Entrance Station 1. Digital name scrolling entrance station • Camera module GH-V A [1] Camera • Speech module GH-D A [2] Speaker [3] In Use LED [4] Microphone • Digital name scrolling.
- 25 - 6-2 Residential station (GH-1MD) [1] V ideo monitor 4 inch black and white CR T [2] Microphone [3] Speaker [4] Light button / Security guard station call b utton [5] Door release / Monitor butt.
- 26 - 8-1 Adjusting the Camera Angle 1. V iew from the initial camera position 2. Changing the camera angle • Remov e the rubber cap. Mov e the lev er to the desired position.
- 27 - 8-3 Making Adjustments with the Mounting Gauge [1] Mounting gauge • T o mount multiple rows of panels, apply the mounting gauge to the mounting bracket. While using the mounting gauge to make adjustments, tighten the scre ws. ∗ There is a mounting gauge for the built-in back box of GF-2B and GF-3B.
- 28 - Setting up the System 1. Make sure that all units are installed and wired properly . T urn on the power switch to GH-BC. When the system includes GH- NS, program the resident information (names and room numbers) in adv ance. (For details, see 8-5) 2.
- 29 - 8-5 Programming (GH-NS) a. Programming with a PC • Y ou can use a PC to enter data and write in or change resident names. • Use the connection cable that comes with GH-NS to connect your PC to GH-NS. • In your PC, install the setup tool program from the CD that comes with the GH-BC.
- 30 - 8-6 4 5 6 1 2 3 7 8 ENGLISH FRANCAIS DEUTSCH ESPANOL NEDERLANDS SELECT LANGUAGE ENGLISH Y OUR OPERA TION DISPLA Y MENU Menu 2 SELECT LANGUAGE DECIDE & BA CK FORW ARD Scroll BACKW ARD DECIDE & NEXT Max. 20 (01)~(20) programmab le ACCESS CODE ACCESS CODE (01) ID 01 (4-digit) ACCESS CODE (02) 8910 Enter a code.
- 31 - 8-6 Program Mode (GH-NS) 1. Menu 1: Select language Choose language to be displayed on GH-NS. 2. Menu 2: Change ID code Enter new ID code starting with " ∗ ", then 4-digit number . (Example: ∗ 1234) 3. Menu 3: Set access code Enter new 4-digit Access Code.
- 32 - 9 SETTING UP (SECURITY GU ARD ST A TION) GH-MK Enter Program Mode Select Menu & Quit 2 B A C 1 3 E D F 5 K J L 4 H G I 6 N M O 8 U T V 7 R Q P S Y X W Z 9 0 2 B A C 1 3 E D F 5 K J L 4 H G .
- 33 - 9-1 Programming (GH-MK) • Make sure that all units are installed and wired properly . T urn on the po wer switch to GH-BC. Program the resident information (names and room numbers) in advance. a. Programming with a PC • Y ou can use a PC to enter data and write in or change resident names.
- 34 - 4 1 2 3 ENGLISH FRANCAIS DEUTSCH ESPANOL NEDERLANDS SELECT LANGUAGE ENGLISH Y OUR OPERA TION DISPLA Y MENU Menu 2 SELECT LANGUAGE DECIDE & BA CK FORW ARD Scroll BACKW ARD DECIDE & NEXT .
- 35 - 9-2 Program Mode (GH-MK) 1. Menu 1: Select language Choose language to be displayed on GH-MK. 2. Menu 2: Change ID code Enter new ID code starting with " ∗ ", then 4-digit number . (Example: ∗ 1234) 3. Menu 3: Write in resident information Register room #s and resident names.
- 36 - 10 OPERA TIONS (ENTRANCE ST A TION) 10-1 Calling a Residential Station 1. Direct Selection GH-SW • Press the call button for the residence that you w ant to call. Y ou will hear a lo w-volume call tone from the entrance station. 2. Digital name scrolling GH-NS • Display the resident name you want to call and press the call button.
- 37 - 10-2 10-3 Calling the Security Guard Station Press the call button once. Y ou will hear a lo w-volume call tone from the entrance station. Door Release 1. Enter the access code. (8-6, Menu 3) 2. The door release function will activ ate at the entrance station.
- 38 - 11-1 11-2 Responding to a Call 1. When the call is from an entrance station or security guard station, the call tone will ring at the residential station for approximately 10 seconds. An image will be displayed on monitor residential station. 2.
- 39 - 11-3 11-4 Door Release 1. Press the door release button while in communication. 2. The door release function will acti vate on the entrance station that is in communication. ∗ Depending on the electric door release system that you use, the door release may be activ e only while the door release b utton is pressed.
- 40 - 11-5 11-6 Calling the Security Guard Station Press the light/security guard station call button on the residential station. Y ou will hear a lo w-volume call tone. When the system is being used for communication, an in-use tone will be heard at the residential station.
- 41 - 11-7 Emergency Alarm 1. Press and lock the emergenc y alarm switch (or when there is a wire disconnection). 2. An alarm will sound from the residential station. 3. When there is a call from the security guard station, the alarm will change to a standard call tone and sound for approximately 45 seconds.
- 42 - 12-1 12-2 Responding to a Call from an Entrance Station 1. When a call is recei ved from an entrance station, a call tone will sound for approximately 10 seconds at the security guard station and the entrance station number will be displayed. Lift the handset and respond.
- 43 - 12-3 12-4 Calling a Entrance Station 1. Lift the handset and press the ∗ button and 1 b utton. 2. Use the 10 key to select the desired entrance station. 3. Press the call button to communicate with the entrance station. If the corresponding entrance station does not exist, "DENIED" will be displayed.
- 44 - 12-6 12-5 Calling Another Security Guard Station Lift the handset and press the " ∗ " button and "1" b utton. Press the "0" button, the security guard station ID (1 -4) b utton and then the call button. Y ou will hear a lo w-volume call tone from the handset.
- 45 - 12-8 12-7 Call T ransfer Function While in standby mode, press " ∗ ", "1" and " ∗ " on a security guard station to display "RECEPTION MODE". In this mode, you can intercept a call from an entrance to a tenant, and transfer the calls directly to the security guard station.
- 46 - T echnical precautions • Operating temperature: Entrance Station: -10 - 60 ° C Residential Station: 0 - 40 ° C Security Guard Station: 0 - 40 ° C Control Unit: 0 - 40 ° C • Mounting loc.
- 47 - Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after deliv ery to the ultimate user and will repair free of charge or replace at no charge, should it become defecti ve upon which e xamination shall disclose to be defectiv e and under warranty .
Een belangrijk punt na aankoop van elk apparaat Aiphone GH series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Aiphone GH series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Aiphone GH series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Aiphone GH series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Aiphone GH series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Aiphone GH series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Aiphone GH series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Aiphone GH series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.