Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan 3SB64417-5A 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B, 2AMX40G2V1B, 2AMX50G2V1B, 2AMX40F2V1B, 2AMX50F2V1B, 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B 2MXS40H2V1B, 2MXS50H2V1B, 2MKS40H2V1B, 2MKS50H2V1B D AIKIN INDUSTRIES, L TD.
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan D AIKIN INDUSTRIES, L TD. EN60335-2-40, DAIKIN.TCF .015 P6/07-2012 DEKRA Certification B.
3SB65451-4.fm Page 2 Thursd ay, October 27, 2011 4:49 PM.
1 ■ English Safety Precautions • The precautions descri bed herein are classified as W ARN ING and CAUTION. They both contain important informa - tion regarding safety . Be sure to observe all precau tions without fail. • Meaning of W ARNING and CAUTION no tices W ARN ING .
■ English 2 Accessories Accessories supplied wit h the outdoor unit: Precautions for Selecting the Location 1) Choose a place soli d enough to bear th e weight and vibratio n of the uni t, where the operation noi se will not be ampli fied.
3 ■ English Indoor/Outdoor Unit Installation Drawings For installation of the indoor units, refer to the insta llation manual which was provided with the units.
■ English 4 Installation • Install the unit horizontally . • The unit may be installed directly on a concrete verandah or a solid place if drai nage is good. • If the vibration may possibly be transmitted to the bu ilding, use a vibration-pr oof rubbe r (field supply).
5 ■ English Outdoor Unit Installation Guideline • Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airflow , follow the instal lation guidelines be low . • For any of the below installation pattern s, the wall height on the exhaust side should be 120 0mm or less.
■ English 6 Refrigerant Piping W ork 1. Installing outdoor unit 1) When installing the outdoor unit, refer to “Precautions for Se lecting the Location” on page 2 and the “Indoor/Outdoor Unit Installation Drawings” on p age 3. 2) If drain work is ne cessary , follow the procedures below .
7 ■ English Refrigerant Piping W ork 4. Purging air and ch ecking gas leakage WARNING • Do not mix any substance other tha n the specifie d refrigerant (R410A) into the refrigera tion cycle. • When refrigerant gas leaks occur , ventilate the room as soon and as much as possible.
■ English 8 5. Refilling the refrigerant Check the type of refrigerant to be used on the machine nameplate. Precautions when adding R410 A Fill from th e gas pipe i n liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, p reventing normal operatio n.
9 ■ English Refrigerant Piping W ork Precautions for Laying Refrigerant Piping • Cautions on pipe handling 1) Protect the open end of the pipe against du st and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending.
■ English 10 Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap s on the liquid an d the gas stop valves at the pipes for rooms A and B. 2) Run the unit on forced cooling.
11 ■ English Wir ing WARNING • Do not use tapped wire s, stranded wires ( CAUTION 1)), extension co rds, or starburst co nnections, as they may cau se over- heating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the produc t.
■ English 12 Maximum Power Input Limitation Setting WARNING Always shut off the power supply breaker before starting. • The Maximum Power Input Limitation needs to be set when the unit is installed. • This function limi ts the power input of the unit to 1700W .
13 ■ English ECONO Mode Prohibition Setting WARNING Always shut off the power supply breaker before starting. • This setting disables the inp ut control signal from the remote controller . • Use this setting when you wish to block receptio n of input controls (cooling/heating) from indoor unit remote co ntrollers.
■ English 14 T rial Operation and T esting • Before starting the test run, measure the voltag e at the primary side of the safety breaker . • Check that all liquid and gas stop valves are fully open. • Check that pipi ng and wiring all match. 1.
(1210) HT 3P210724-1F M07B062F Two-dimensio nal bar code is a code for manufact uring. 00_CV_3P210724-1F.fm Page 2 Tu esday, October 30, 2012 10: 36 AM.
Een belangrijk punt na aankoop van elk apparaat Daikin 2AMX50G3V1B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Daikin 2AMX50G3V1B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Daikin 2AMX50G3V1B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Daikin 2AMX50G3V1B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Daikin 2AMX50G3V1B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Daikin 2AMX50G3V1B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Daikin 2AMX50G3V1B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Daikin 2AMX50G3V1B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.