Operating Instructions & Parts Manual 3VG79B Dayton Portable For ced Air Heater Description Dayton Model 3VG79B is a 200,000 Btu/Hr heater . This heater uses only Kerosene or No.
Dayton Operating Instructions and Parts Manual 2 Dayton Portable For ced Air Heater ® 3VG79B Figure 2 - Model 3VG79B Product Identification Thermostat Knob General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference.
Dayton Operating Instructions and Parts Manual 3 Model 3VG79B Version B - For Reduction G016.J ® Carbon monoxide poisoning may lead to death! Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 4 Dayton Portable For ced Air Heater ® 3VG79B Fuels Use only Kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
Dayton Operating Instructions and Parts Manual 5 Model 3VG79B Version B - For Reduction G016.J ® 4. Place handles on top of fuel tank flange. Insert scr ews through handles, fuel tank flange, and wheel support frame. Attach nut finger tight after inserting each screw .
Dayton Operating Instructions and Parts Manual 6 Dayton Portable For ced Air Heater ® 3VG79B 7. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds). 8. Replace fan guard and upper shell. AIR OUTPUT , AIR INT AKE, AND LINT FIL TERS 1.
Dayton Operating Instructions and Parts Manual 7 Model 3VG79B Version B - For Reduction G016.J ® Maintenance (Continued) Side Cover Bushing, Lower Fuel Line, and Fuel Filter Figure 10 - Fuel Filter Removal Fuel V alve Fitting 4. Disconnect red and white wir es fr om fuel valve (See Figure 11).
Dayton Operating Instructions and Parts Manual 8 Dayton Portable For ced Air Heater ® 3VG79B Maintenance (Continued) Figure 13 - Ignitor Replacement Combustion Chamber Photocell Bracket Ignitor Ignitor Screw Nozzle Adapter Bracket Nozzle Adapter Bracket Opening Ignitor Element Washer NOZZLE ASSEMBL Y 1.
Dayton Operating Instructions and Parts Manual 9 Model 3VG79B Version B - For Reduction G016.J ® Sandpaper Figure 18 - Sanding Rotor Maintenance (Continued) STORING, TRANSPORTING, OR SHIP- PING NOTE: If shipping, transport companies requir e fuel tanks to be empty .
Dayton Operating Instructions and Parts Manual 10 Dayton Portable For ced Air Heater ® 3VG79B For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 11 Model 3VG79B Version B - For Reduction G016.J ® Ref. Part 2E510D 2E511D No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 12 Dayton Portable For ced Air Heater ® 3VG79B Figure 23 - Replacement Parts Illustration Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 13 Model 3VG79B Version B - For Reduction G016.J ® Ref. Part No. Description Number Qty . Ref. Part No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable For ced Air Heater ® 3VG79B Replacement Parts List for Handle and Wheel Group Ref. Part No.
Dayton Operating Instructions and Parts Manual 15 Model 3VG79B Version B - For Reduction G016.J ® 1. No power to heater 2. Thermostat setting to low 3. Bad electrical connection between motor and ignition control assembly or ignition control assembly and power cor d 4.
Dayton Operating Instructions and Parts Manual 16 Dayton Portable For ced Air Heater ® 3VG79B Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. 107326-01 Rev . D 12/00 Version B - For Reduction G016.J ® NOT A UPC LIMITED WARRANTY DA YTON ONE-YEAR LIMITED WARRANTY .
Een belangrijk punt na aankoop van elk apparaat Dayton 3VG79B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dayton 3VG79B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dayton 3VG79B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dayton 3VG79B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dayton 3VG79B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dayton 3VG79B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dayton 3VG79B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dayton 3VG79B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.