Dell PowerEdge R920 System Owner's Manual Regulatory Model: E23S Series Regulatory Type: E23S001.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Contents 1 About Your System...................................................................................................................... 9 Front-Panel Features And Indicators ..................................................................
Using The Boot Manager Navigation Keys ...................................................................................................... 31 Boot Manager Screen ......................................................................................
Installing A 2.5 Inch Hard-Drive Blank ............................................................................................................. 56 Removing A Hot-Swap Hard Drive ....................................................................
Processors .............................................................................................................................................................. 83 Removing A Heat Sink Blank ...................................................
Troubleshooting A Serial I/O Device .................................................................................................................... 117 Troubleshooting A Wet System .................................................................
Documentation feedback ................................................................................................................................
1 About Your System Front-Panel Features And Indicators Figure 1. Front-Panel Features and Indicators Item Indicator, Button, or Connector Icon Description 1 Power-on indicator, power button The power-on indicator lights when the system power is on. The power button controls the power supply output to the system.
Item Indicator, Button, or Connector Icon Description Press to toggle the system ID on and off. If the system stops responding during POST, press and hold the system ID button for more than five seconds to enter BIOS progress mode. To reset iDRAC (if not disabled in F2 iDRAC setup), press and hold the button for more than 15 seconds.
• The LCD backlight remains off if LCD messaging is turned off through the iDRAC utility, the LCD panel, or other tools. Figure 2. LCD Panel Features Item Button Description 1 Left Moves the cursor back in one-step increments. 2 Select Selects the menu item highlighted by the cursor.
Option Description Set error Select SEL to display LCD error messages in a format that matches the IPMI description in the SEL. This is useful when trying to match an LCD message with an SEL entry. Select Simple to display LCD error messages in a simplified user-friendly description.
Drive-Status Indicator Pattern (RAID Only) Condition Blinks green two times per second Identifying drive or preparing for removal Off Drive ready for insertion or removal NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on.
State Name Slot/Device State Status LED (Green) Status LED (Amber) Device identify (blink) The device is identifying the slot location or is indicating the device has received a Prepare for Removal command from the host operating system.
Item Indicator, Button, or Connector Icon Description 4 Serial connector Allows you to connect a serial device to the system. 5 USB connectors (2) Allows you to connect USB devices to the system.
Indicator Indicator Code Link and activity indicators are off The NIC is not connected to the network. Link indicator is green The NIC is connected to a valid network at its maximum port speed (1 Gbps or 10 Gbps). Link indicator is amber The NIC is connected to a valid network at less than its maximum port speed.
Power Indicator Pattern Condition Not lit Power is not connected. Green The handle/LED indicator lights green indicating that a valid power source is connected to the power supply and that the power supply is operational. Flashing amber Indicates a problem with the power supply.
• For more information on the system and how-to videos, scan the Quick Resource Locator (QRL) available on your system. NOTE: Download the QRL application from your mobile platform to enable the application on your mobile device. • Always check for updates on dell.
2 Using The System Setup and Boot Manager System Setup enables you to manage your system hardware and specify BIOS-level options. The following keystrokes provide access to system features during startup: Keystroke Description <F2> Opens the System Setup page.
• UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI) specifications that overlays the system BIOS. You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup.
System Setup Options System Setup Main Screen NOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings. Menu Item Description System BIOS This option is used to view and configure BIOS settings. iDRAC Settings This option is used to view and configure iDRAC settings.
Menu Item Description System BIOS Version Displays the BIOS version installed on the system. System Service Tag Displays the system Service Tag. System Manufacturer Displays the name of the system manufacturer. System Manufacturer Contact Information Displays the contact information of the system manufacturer.
Menu Item Description Adjacent Cache Line Prefetch Allows you to optimize the system for applications that require high utilization of sequential memory access. By default, the Adjacent Cache Line Prefetch option is set to Enabled . You can disable this option for applications that require high utilization of random memory access.
Boot Settings Screen Menu Item Description Boot Mode Allows you to set the boot mode of the system. CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not installed in the same boot mode. If the operating system supports UEFI, you can set this option to UEFI.
Menu Item Description NOTE: This option is displayed only if IDSDM is installed on the system board. Integrated Network Card 1 Allows you to enable or disable the integrated network card 1. By default, the Integrated Network Card 1 option is set to Enabled .
Menu Item Description Redirection After Boot Allows you to enable or disable to the BIOS console redirection when the operating system is loaded. By default, the Redirection After Boot option is set to Enabled . System Profile Settings Screen Menu Item Description System Profile Allows you to set the system profile.
System Security Screen Menu Item Description Intel AES-NI The Intel AES-NI option improves the speed of applications by performing encryption and decryption using the Advanced Encryption Standard Instruction Set and is set to Enabled by default. System Password Allows you to set the system password.
Miscellaneous Settings Menu Item Description System Time Allows you to set the time on the system. System Date Allows you to set the date on the system. Asset Tag Displays the asset tag and allows you to modify it for security and tracking purposes. Keyboard NumLock Allows you to set whether the system boots with the NumLock enabled or disabled.
To assign a system and/or setup password: 1. To enter System Setup, press <F2> immediately after a power-on or reboot. 2. In the System Setup Main Menu , select System BIOS and press <Enter>. The System BIOS screen is displayed. 3. In the System BIOS screen, select System Security and press <Enter>.
Using Your System Password To Secure Your System NOTE: If you have assigned a setup password, the system accepts your setup password as an alternate system password. 1. Turn on or reboot your system. 2. Type your password and press <Enter>. When Password Status is Locked , type the password and press <Enter> when prompted at reboot.
Using The Boot Manager Navigation Keys Key Description Up arrow Moves to the previous field. Down arrow Moves to the next field. <Enter> Allows you to type in a value in the selected field (if applicable) or follow the link in the field. Spacebar Expands or collapses a drop-down list, if applicable.
Menu Item Description Add Boot Option Adds a new boot option. Delete Boot Option Deletes an existing boot option. Boot From File Sets a one-time boot option not included in the boot option list. Embedded System Management The Dell Lifecycle Controller provides advanced embedded systems management throughout the server’s lifecycle.
3 Installing System Components Recommended Tools You may need the following items to perform the procedures in this section: • Key to the system keylock • #2 Phillips screwdriver • 10 in-lb.
Figure 9. Removing and Installing the Front Bezel 1. release latch 2. front bezel 3. locking hooks Installing The Front Bezel 1. Hook the right end of the bezel onto the chassis. 2. Fit the free end of the bezel onto the chassis. 3. Secure the bezel with the keylock.
Opening The System NOTE: It is recommended that you always use a static mat and static strap while working on components inside the system. 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 2. Rotate the latch release lock counter clockwise to the unlocked position.
Inside The System CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Chassis Intrusion Switch CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Figure 12. Removing and Installing the Chassis Intrusion Switch 1. chassis intrusion switch 2. NDC riser (riser 1) 3. chassis intrusion switch cable Cable Management Tray The cable management tray is located above the processor heat sinks.
Figure 13. Removing and Installing the Cable Management Tray 1. cable tray slot (4) 2. cable tray hook (4) 3. cable tray cover 4. cable tray cover release tab 5. cables (routed) Installing The Cable Management Tray 1. Position the cable management tray above the processor heat sinks.
Memory bus operating frequency can be 1066 MT/s, 1333 MT/s, and 1600 MT/s depending on: • DIMM type (RDIMM and LRDIMM) • DIMM configuration (number of ranks) • Maximum frequency of the DIMMs •.
Figure 14. Memory Socket Locations Memory channels are organized as follows: Processor 1 channel 0: slots A1, A5, and A9 channel 1: slots A2, A6, and A10 channel 2: slots A3, A7, and A11 channel 3: sl.
channel 2: slots E3, E7, and E11 channel 3: slots E4, E8, and E12 channel 0: slots F1, F5, and F9 channel 1: slots F2, F6, and F10 channel 2: slots F3, F7, and F11 channel 3: slots F4, F8, and F12 Pro.
DIMM Type DIMMs Populated/ Channel (DPC) DIMM Size Operating Frequency (in MT/s) Maximum DIMM Rank/ Channel DDR3 (1.5 V) DDR3 (1.35 V) 2 32 GB / 64 GB 1600 1333 Quad rank physical 3 32 GB / 64 GB 1333.
• Memory modules must be identical in size, speed, and technology. • DIMMs installed in memory sockets with white release tabs must be identical and similar rule applies for sockets with black and green release tabs. This ensures that identical DIMMs are installed in matched pairs - for example, A1 with A2, A3 with A4, A5 with A6, and so on.
NOTE: DIMMs populated must be identical for each riser. In the mirroring mode, only one of the two CPUs is populated. NOTE: 64GB LRDIMMs are supported by the system.
Memory Mode System Capacity (in GB) DIMM Size (in GB) Number of DIMMs DIMM Slot Population for CPU 1 ( Riser A and B) 128 16 8 X X X X 96 16 6 X X X 128 16 8 X X X X 192 32 6 X X X 256 32 8 X X X X 19.
Removing A Memory-Riser Blank CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Installing A Memory-Riser Blank CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Figure 16. Removing and Installing the Memory Riser 1. memory riser handle 2. memory riser handle lock 3. memory riser guide Installing A Memory Riser 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
6. Press the handle down by pushing on the blue touch points and sliding the handle lock until it clicks into the locked position. NOTE: If the memory riser is not aligned with the riser guide, the memory riser will not slide smoothly into the slot.
Figure 17. Opening and Closing the Memory Riser 1. memory riser release tabs 2. memory riser cover 3. memory riser handle 5. Locate the appropriate memory-module socket(s). 6. To release the memory-module blank from the socket, simultaneously press the ejectors on both ends of the memory module socket.
Figure 18. Ejecting The Memory Module 1. memory module 2. memory-module socket ejectors (2) 3. memory-module socket 7. If a memory module or a memory-module blank is installed in the socket, remove it. NOTE: Retain the removed memory-module blank(s) for future use.
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets. 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
13. Reconnect the system to its electrical outlet and turn on the system, including any attached peripherals. 14. Press <F2> to enter the System Setup, and check the memory settings. The system should have already changed the value to reflect the newly installed memory.
Figure 21. Removing and Installing the Memory Riser and Fan Cage 1. memory riser and fan cage handle 2. fan cage 3. memory riser and fan cage back handle 4.
6. Install cooling fans. 7. Close the system. 8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Hard Drives All hard drives connect to the system board through the hard-drive backplane. Hard drives are supplied in hot- swappable hard-drive carriers that fit in the hard-drive slots.
Removing A Hot-Swap Hard Drive CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation supplied with your operating system. 1. From the management software, prepare the hard drive for removal.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation supplied with your operating system. CAUTION: When a replacement hot-swappable hard drive is installed and the system is powered on, the hard drive automatically begins to rebuild.
Installing A Hard Drive Into A Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Figure 25. Removing and Installing the Optical Drive 1. ejector-handle button 2. optical drive sled 3. ejector handle Installing The Optical Drive CAUTION: Many repairs may only be done by a certified service technician.
WARNING: Do not place any physical obstructions in the front or rear of the chassis. This may cause a decrease in airflow, resulting in an over-heating condition. Removing A Cooling Fan WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric shock.
Installing A Cooling Fan CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Figure 27. Removing and Installing the Fan Tray 1. fan tray connector 2. fan tray Installing The Fan tray 1. Align the fan tray with the connector and the screw holes on the system board. 2. Lower the fan tray and ensure that the fan tray connector engages with the connector on the system board.
Replacing The Internal USB Key CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Expansion Card Installation Guidelines Your system supports third Generation 10 PCIe expansion card slots that include one dedicated slot for PERC 9 storage card and one dedicated riser-slot for Network Daughter Card (NDC). Slot 1 connector functions as an x8 connector and can be extended as two x4 slots when the left I/O riser is installed.
Table 4. Expansion Card Installation Order Card Priority Card Type Form Factor Slot Priority (Two Processors) Slot Priority (Four Processors) Max Allowed 1 Internal Storage (Integrated Slot) Full Heig.
To remove the left expansion card riser blank: 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2. Open the system. 3. Slide the left riser blank to the left pressing on the metal tab. 4.
3. Align the left riser blank with the corresponding slot on the back of the chassis. 4. Press down and slide the blank to the right to lock it in place and replace the PCI retention rocker. Removing The Right Expansion Card Riser Blank CAUTION: Many repairs may only be done by a certified service technician.
Figure 30. Removing and Installing Expansion-Card Risers 2 and 3 Cage 1. expansion-card riser 2 cage 2. expansion-card riser handle 3. expansion-card riser 3 cage 4.
Figure 31. Removing and Installing the Expansion-Card (half-length) from the Expansion-Card Riser 2 1. expansion-card connector on the riser 2. expansion-card (half-length) 3.
Figure 32. Removing and Installing the Expansion-Card (full-length) from the Expansion-Card Riser 2 1. expansion-card connector on the riser 2. expansion-card (full-length) 3.
Figure 33. Removing The Metal Brackets To Install The Full-Length Expansion Cards 1. memory riser and fan cage 2. left metal bracket 3. right metal bracket Figure 34. Removing and Installing the Expansion-Card from the Expansion-Card Riser 3 1. expansion-card riser cage 2.
Installing An Expansion Card Into The Expansion-Card Riser 2 and 3 CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
6. Press and slide out the NDC riser panel latch. The NDC riser panel is unlocked. 7. Hold the NDC riser and carefully remove it from the connector on the system board. Figure 35. Removing and Installing the NDC Riser 1. NDC 2. PCI retention rocker 3.
5. Close the system. 6. If applicable, reconnect the external cables to the IO card. 7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Figure 36. Removing and Installing the Network Daughter Card 1. NDC panel 2. I/O riser card 3. NDC connector on the I/O riser card 4. screw (2) 5. network daughter card Installing The Network Daughter Card CAUTION: Many repairs may only be done by a certified service technician.
Replacing An SD vFlash Card 1. Locate the vFlash media slot on the system. 2. To remove the SD vFlash card, push inward on the card to release it, and pull the card from the card slot. Figure 37. Removing and Installing the SD vFlash Card 1. SD vFlash card 2.
Figure 38. Removing and Installing the Internal Dual SD Module 1. connector on the I/O card 2. internal dual SD module 3. blue pull tab Installing The Internal Dual SD Module CAUTION: Many repairs may only be done by a certified service technician.
Removing An Internal SD Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Installing An Internal SD Card CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
9. Close the system. 10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. Figure 40. Removing and Installing the Integrated Storage Controller Card 1. SAS cable connector 2. storage controller card battery 3.
7. Close the clamp. 8. Install the NDC riser. 9. If applicable, reinstall the left expansion card riser. 10. Close the system. 11. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. RAID Battery Removing a RAID Battery CAUTION: Many repairs may only be done by a certified service technician.
Installing The RAID Battery CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
5. Press the heat sink release tabs located at the back of the blank. 6. Lift the heat sink blank out of the system. Figure 42. Removing and Installing the Heat Sink Blank 1. heat sink blank 2. processor blank Installing A Heat Sink Blank CAUTION: Many repairs may only be done by a certified service technician.
Removing A Processor CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Figure 43. Removing and Installing the Processor Heat Sink 1. heat sink 2. retention screws (4) 3. retention sockets (4) 4. processor CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up suddenly if not firmly grasped.
Figure 44. Processor Shield Opening and Closing Lever Sequence 1. processor socket-release lever 2. close-lock symbol 3. processor 4. processor socket-release lever 5. open-lock symbol 14. Rotate the processor shield upward and out of the way. CAUTION: The socket pins are fragile and can be permanently damaged.
Figure 45. Removing and Installing a Processor 1. processor socket-release lever 2. processor 3. processor shield 4. processor socket-release lever 5. notches in processor 6. socket keys 7. pin 1 indicator 8. ZIF socket NOTE: After removing the processor, place it in an antistatic container for reuse, return, or temporary storage.
NOTE: If you are installing two processors, they must be installed in socket CPU1 and CPU2. 1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
Your system supports Up to four 750 W, 1100 W, and 1600 W (when available) AC power supply modules Or Up to four 1100 W DC power supply modules NOTE: You can install only one 1600 W power supply on each side of the system. When two identical power supplies are installed, the power supply configuration is redundant (1 + 1).
Figure 46. Removing and Installing an AC Power Supply 1. connector 2. power supply 3. release latch 4. power supply handle Installing An AC Power Supply CAUTION: Many repairs may only be done by a certified service technician.
Wiring Instructions For A DC Power Supply Your system supports up to two –(48–60) V DC power supplies (when available). WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds.
3. Connect the safety ground wire to the grounding post on the back of the system using a #6-32 nut equipped with a locking washer. Figure 47. Assembling and Connecting the Safety Ground Wire 1. safety ground wire 2. grounding post 3. locking washer 4.
Figure 48. Assembling the DC Input Power Wires 1. DC power socket 2. rubber cap 3. captive screws (2) 4. DC power connector 5. wire –48 V 6. wire RTN 7. grounding wire Removing A DC Power Supply WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds.
Figure 49. Removing and Installing a DC Power Supply 1. connector 2. power supply 3. power supply status indicator 4. release latch 5. power supply handle Installing A DC Power Supply WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds.
Removing The Power Supply Blank CAUTION: To ensure proper system cooling, the power supply blank must be installed in the second power supply bay in a non-redundant configuration. Remove the power supply blank only if you are installing a second power supply.
Removing The Power Supply Bay CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
3. power supply bay (left) 4. power supply bay (right) 5. finger grips on the power supply bay Installing The Power Supply Bay 1. Position the power supply bay to the side of the chassis. 2. Align four slots on the power supply bay with the hooks on the side wall of the chassis.
Figure 52. Removing and Installing the Power Distribution Board 1. screw (3) 2. power distribution board 3. power supply bay (left) 4. power supply bay (right) Installing The Power Distribution Board CAUTION: Many repairs may only be done by a certified service technician.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty.
• 2.5 inch (x24) SAS/SATA backplane • 2.5 inch (x16) SAS/SATA backplane and 2.5 inch (x8) Dell PowerEdge Express Flash (PCIe SSD) backplane Removing The Hard-Drive Backplane CAUTION: Many repairs may only be done by a certified service technician.
Figure 54. Removing and Installing the 2.5 Inch (x4) SAS/SATA Backplane 1. release tab 2. system board miscellaneous signal cable 3. SAS connector 4. hard drive connector 5. backplane hook (4) 6. backplane power cable Figure 55. 2.5 Inch (x4) SAS/SATA Backplane—Front view 1.
Figure 56. 2.5 Inch (x4) SAS/SATA Backplane—Back view 1. backplane power cable 2. system board miscellaneous signal cable Figure 57. Removing and Installing the 2.5 Inch (x24) SAS/SATA Backplane 1. release tab (2) 2. backplane jumper connector 3. backplane jumper connector for the expander daughter card 4.
Figure 58. 2.5 Inch (x24) SAS/SATA Backplane—Front view 1. jumper connector 2. hard drive connector 3. SAS connector 4. hard drive connector 5. backplane loops 6. backplane hook (8) 7. backplane jumper connector Figure 59. 2.5 Inch (x24) SAS/SATA Backplane—Back view 1.
Figure 60. Removing and Installing the 2.5 Inch (x16) SAS/SATA and (x8) PCIe SSD Backplane 1. release tab (2) 2. backplane jumper connector 3. system board miscellaneous signal cable 4. primary PCIe SSD extender mini-SAS HD connector (4) 5. SAS connector 6.
5. backplane hook (8) 6. jumper connector to the expander daughter card Figure 62. Cabling—2.5 Inch (x4) SAS/SATA Backplane with PERC 9 1. SAS cable connector on the integrated storage controller card 2. integrated storage controller card (PERC 9) 3.
Figure 63. Cabling—2.5 Inch (x24) SAS/SATA Backplane with PERC 9 1. SAS (A&B) cable connector on the integrated storage controller card 2. integrated storage controller card (PERC 9) 3. system board 4. cable management tray 5. x24 hard drive backplane 6.
Figure 64. Cabling—2.5 Inch (x16) SAS/SATA and (x8) PCIe SSD Backplane (left and right side) 1. SAS (A&B) cable connector on the integrated storage controller card 2. integrated storage controller card 3. system board 4. cable management tray 5.
Figure 65. Cabling— x24 Backplane With Dual PERC And Dual SAS Expander Cards 1. SAS cable connector on the primary integrated storage controller card 2. integrated storage controller card (primary card) 3. integrated storage controller card (secondary card) 4.
Installing The Hard-Drive Backplane CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
6. Pull and remove the SAS expander daughter card sled out of the system chassis. Figure 66. Removing and Installing the SAS Expander Daughter Card 1. SAS expander daughter card sled 2. release tab (2) Installing The SAS Expander Daughter Card 1. Press the two release tabs inwards to release the lock.
NOTE: Note the routing of the cables on the side of the system as you remove them from the control panel board. You must route these cables properly when you replace them inside the shim stock pieces to prevent them from being pinched or crimped.
4. Close the system. 5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. System Board Removing The System Board CAUTION: Many repairs may only be done by a certified service technician.
Figure 68. Removing and Installing the System Board 1. release pin 2. system board Installing The System Board CAUTION: Many repairs may only be done by a certified service technician.
j. cooling fans (6) k. cable management tray l. SAS backplane m. internal USB key (if installed) n. optical drive 5. Reconnect the cables to the system board, hard-drive backplane, control panel board, and the optical drive cable (if applicable).
4 Troubleshooting Your System Safety First—For You And Your System CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
6. If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to the system. 7. Power down all attached USB devices and disconnect them from the system. 8. Reboot the system and, if your keyboard is functioning, enter the System Setup.
• Memory riser and fan cage • Processor(s) and heat sink(s) 4. Let the system dry thoroughly for at least 24 hours. 5. Reinstall the components you removed in step 3. 6. Close the system. 7. Turn on the system and attached peripherals. If the system does not start properly, see Getting Help .
Troubleshooting The System Battery CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
• The expansion card installation guidelines have not been followed. Troubleshooting Cooling Fans CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
14. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module with a known good memory module. 15.
CAUTION: If the Internal SD Card Redundancy option is set to Mirror Mode in the Integrated Devices screen of the System Setup, you must follow the instructions in step 4 through step 7 to avoid loss of data. NOTE: When an SD card failure occurs, the internal dual SD module controller notifies the system.
a. Restart the system and press <F10> during system startup to run the Lifecycle Controller, and then run the Hardware Configuration wizard to check the RAID configuration. See the Lifecycle Controller documentation or online help for information on RAID configuration.
Troubleshooting Expansion Cards CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
10. Open the system. 11. Remove the memory risers, cooling fans, and memory riser and fan cage. 12. If your system has four processors, remove all processors except for processor 1 and processor 2. 13. Install the memory riser and fan cage, cooling fans and memory risers.
5 Using System Diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss.
Menu Description System Health Provides the current overview of the system performance. Event Log Displays a time-stamped log of the results of all tests run on the system.
6 Jumpers And Connectors System Board Jumper Settings For information on resetting the password jumper to disable a password, see Disabling A Forgotten Password. Table 5. System Board Jumper Settings Jumper Setting Description PWRD_EN (default) The password feature is enabled (pins 4–6).
System Board Connectors Figure 69. System Board Jumpers and Connectors Item Connector Description 1 J_VIDEO VGA connector 2 JA_IDRAC_RG45 IDRAC connector 3 INT_STORAGE/ J_PERC Integrated storage contr.
Item Connector Description 7 J_PCIE_SLOT9 Right I/O Riser Connector (Optional) 8 USB1/USB2 J_USB USB connector 9 J_SERIAL Serial connector 10 JA_CYC System Identification connector 11 W_CYC_ID System .
Figure 70. Expander Daughter Card board Jumpers and Connectors (Unified Mode) Item Connector Description 1 J_SAS_A1 SAS A1 connector 2 J_SAS_A SAS A connector 3 J_XCEDE_SAS1 SAS 1 connector 4 J_XCEDE_SAS2 SAS 2 connector 5 J_SAS_B SAS B connector 6 J_SAS_B1 SAS B1 connector Figure 71.
Item Connector Description 1 J_SAS_A SAS A connector 2 J_XCEDE_SAS1 SAS 1 connector 3 J_XCEDE_SAS2 SAS 2 connector 4 J_SAS_B SAS B connector 5 J_SAS_A SAS A connector 6 J_XCEDE_SAS1 SAS 1 connector 7 .
7 Technical Specifications Processor Processor type Two or Four Intel Xeon Processor E7-8800/4800/2800 v2 product family Power AC Power Supply (per power supply) Wattage 750 W, 1100 W, or 1600 W (when available) NOTE: Your system supports a maximum of two 1600 W power supplies.
Expansion Bus (Slot 2/2) One full-height, half-length x4 link (Slot 3) One full-height, half-length x8 link (Slot 4) One full-height, full-length x16 link NOTE: To use slots 6 through 10, all four processors must be installed.
Drives • 3Gb/s and 6Gb/s on SATA drives. NOTE: With single Unified mode daughter card and PERC 9 card the hard-drives are located in hard-drive slots 0 through 24 (bay 1).
Connectors NOTE: The card slot is available for use only if the iDRAC7 Enterprise license is installed on your system. Internal USB One 4-pin, USB 2.0-compliant Internal Dual SD Module Two optional flash memory card slots with the internal SD module NOTE: One card slot is dedicated for redundancy.
NOTE: Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data centers. NOTE: For additional information about environmental measurements for specific system configurations, see dell.
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution.
8 System Messages LCD Messages NOTE: Applicable only if your system has an LCD display. The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings, see the systems management software documentation.
Error Code Message Information AMP0302 Message The system board < name > current is greater than the upper warning threshold. Details System board < name > current is outside of the optimum range. Action 1. Review system power policy. 2. Check system logs for power related failures.
Error Code Message Information ASR0003 Message The watchdog timer power cycled the system. Details The operating system or an application failed to communicate within the time-out period. The system was power-cycled. Action Check the operating system, application, hardware, and system event log for exception events.
Error Code Message Information Action Review the technical specifications for supported processor types. CPU0010 Message CPU < number > is throttled. Details The CPU is throttled due to thermal or power conditions. Action Review system logs for power or thermal exceptions.
Error Code Message Information 2. Turn off the system and remove input power for one minute. 3. Ensure the processor is seated correctly. 4. Reapply input power and turn on the system. 5. If the issue persists, see Getting Help . CPU0702 Message CPU bus parity error detected.
Error Code Message Information 5. If the issue persists, see Getting Help . FAN0000 Message Fan < number > RPM is less than the lower warning threshold. Details Fan operating speed is out of range. Action Remove and reinstall the fan. If the issue persists, see Getting Help .
Error Code Message Information Action Check if the cable is present, then reinstall or reconnect. MEM0000 Message Persistent correctable memory errors detected on a memory device at location(s) < location >. Details This is an early indicator of a possible future uncorrectable error.
Error Code Message Information LCD Message Memory mirror lost on < location >. Power cycle system. Details The memory may not be seated correctly, misconfigured, or has failed. Action Check the memory configuration. Re-seat the memory modules. If the issue persists, see Getting Help .
Error Code Message Information Action Cycle input power, update component drivers, if device is removable, reinstall the device. PCI1320 Message A bus fatal error was detected on a component at bus < bus >device< device >function < func >.
Error Code Message Information LCD Message Drive < number > removed from disk drive bay < bay >. Check drive. Details The controller detected that the drive was removed. Action Verify drive installation. Re-seat the failed drive. If the issue persists, see Getting Help .
Error Code Message Information PSU0006 Message Power supply < number > type mismatch. LCD Message Power supply < number > is incorrectly configured. Check PSU. Details Power supplies should be of the same input type and power rating. Action Install matched power supplies and review proper configuration in this manual.
Error Code Message Information PSU0034 Message An under voltage fault detected on power supply < number >. LCD Message An under voltage fault detected on PSU < number >. Check power source. Details This failure may be the result of an electrical issue with cables or subsystem components in the system.
Error Code Message Information PSU1201 Message Power supply redundancy is lost. Details The power supply tries to operate in a degraded state. System Performance and power redundancy may be degraded or lost. Action Check input power. Reinstall the power supply.
Error Code Message Information Details An error was reported during a SD card read or write. Action Reseat the flash media. If the problem persists, see Getting Help . RFM1014 Message Removable Flash Media < name > is write protected. LCD Message Removable Flash Media < name > is write protected.
Error Code Message Information SEC0031 Message The chassis is open while the power is on. LCD Message Intrusion detected. Check chassis cover. Details The chassis is open. System performance may be degraded, and security may be compromised. Action Close the chassis.
Error Code Message Information Action Re-configure system to the minimum supported configuration. If issues persists, contact support. TMP0118 Message The system inlet temperature is less than the lower warning threshold. LCD Message System inlet temperature is outside of range.
Error Code Message Information Action 1. Review system logs for power supply exceptions. 2. Re-configure the system to minimum configuration, inspect and reinstall system cables.
9 Getting help Contacting Dell Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog.
Documentation feedback If you have feedback for this document, write to documentation_feedback@dell.com . Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit to send your feedback.
Een belangrijk punt na aankoop van elk apparaat Dell E23S Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dell E23S Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dell E23S Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dell E23S Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dell E23S Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dell E23S Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dell E23S Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dell E23S Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.