Dell PowerVault MD3660i Series Storage Arrays Deployment Guide.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Contents Notes, Cautions, and Warnings ...................................................................................................2 1 Introduction ................................................................................................
Using A DHCP server ........................................................................................................................................27 Using A Static IP Address ..................................................................
For Windows Server 2008 GUI Version ............................................................................................................ 42 For Windows Server 2008 Core Version ..................................................................
6.
1 Introduction This guide provides information about deploying Dell PowerVault MD3660i storage arrays. The deployment process includes: • Hardware installation • Modular Disk Storage Manager (MD S.
One or more host servers attached to the storage array can access the data on the storage array. You can also establish multiple physical paths between the host(s) and the storage array so that loss of any single path (for example, through failure of a host server port) does not result in loss of access to data on the storage array.
2 Hardware Installation Before using this guide, ensure that you review the instructions in the: • Getting Started Guide —The Getting Started Guide that shipped with the storage array, provides information to configure the initial setup of the system.
Redundant And Non-Redundant Configurations Non-redundant configurations are configurations that provide only a single data path from a host to the storage array.
Figure 1. Four Hosts in a Dual-Controller Configuration In the following figure, up to two servers are directly attached to the RAID controller modules. If the host server has a second Ethernet connection to the array, it can be attached to the iSCSI ports on the array's second controller.
Figure 2. Two Hosts Connected to Two Controllers In the following figure, up to two cluster nodes are directly attached to two RAID controller modules. Since each cluster node has redundant paths, loss of a single path still allows access to the storage array through the alternate path.
Figure 3. Two Cluster Nodes Connected to Two Controllers 13.
Network-Attached Configurations You can also cable the host servers to the RAID controller module iSCSI ports through industry-standard 10 Gbps or 1 Gbps Ethernet switches. An iSCSI configuration that uses Ethernet switches is frequently referred to as an IP SAN.
Figure 4. 64 Servers Connected to Two Controllers The following figure shows up to 64 stand-alone servers attached (using multiple sessions) to a dual RAID controller configuration through a network using a 1 Gbps to 10 Gbps aggregation scheme. The NICs on the servers are 1 Gbps NICs and the uplink ports on the 1 Gbps switches are 10 Gbps.
network allow two separate physical paths for each host, which ensures full redundancy if one of the paths fails. It is recommended you use two switches for more redundancy.
Cabling PowerVault MD3060e Expansion Enclosures You can expand the capacity of your PowerVault MD3660i Series storage array by adding PowerVault MD3060e expansion enclosures. You can expand the physical disk pool to a maximum of 120 (or 180, if enabled using Premium Feature activation) physical disks using a maximum of two expansion enclosures.
15. After the PowerVault MD3060e Series expansion enclosure is configured as an expansion enclosure of the storage array, restore the data that was backed up in step 1.
3 Installing MD Storage Manager The PowerVault MD Series resource media contains software and drivers for both Linux and Microsoft Windows operating systems. The root of the media contains a readme.txt file covering changes to the software, updates, fixes, patches, and other important data applicable to both Linux and Windows operating systems.
Graphical Installation (Recommended) The MD Storage Manager configures, manages, and monitors the storage array. To install the MD storage manager: 1. Insert the PowerVault MD Series resource media. Depending on your operating system, the installer may launch automatically.
Silent Installation Silent Installation On Windows To run silent installation on a Windows system: 1. Copy the custom_silent.properties file in the /windows folder of the installation media or image to a writable location on the host server. 2. Modify the custom_silent.
22.
4 Post Installation Tasks Before using the storage array for the first time, complete a number of initial configuration tasks in the order shown. These tasks are performed using the MD Storage Manager.
iSCSI Configuration Worksheet The IPv4 Settings — Worksheet and IPv6 Settings — Worksheet helps you plan your configuration. Recording host server and storage array IP addresses at a single location enables you to configure your setup faster and more efficiently.
Storage Array Configuration Before a host iSCSI initiator and an iSCSI-based storage array can communicate, they must be configured with information such as which IP addresses and authentication method to use.
• For redundancy in a dual controller (duplex) configuration, ensure each host network interface is configured to connect to both storage array controllers. • For optimal load balancing, ensure each host network interface that is used for iSCSI traffic is configured to connect to each storage array controller.
5 Guidelines For Configuring Your Network For iSCSI This section provides general guidelines for setting up your network environment and IP addresses for use with the iSCSI ports on your host server and storage array.
3. Restart network services using the following command: /etc/init.d/network restart Using A DNS Server If you are using static IP addressing: 1. In the Control Panel , select Network connections or Network and Sharing Center and then click Manage network connections .
NETWORKING=yes HOSTNAME=mymachine.mycompany.com 2. Edit the configuration file for the connection you want to configure, either /etc/sysconfig/network-scripts/ifcfg-ethX (for Red Hat Enterprise Linux) or /etc/sysconfig/network/ifcfg-eth-id-XX:XX:XX:XX:XX (for SUSE Enterprise Linux).
30.
6 Uninstalling MD Storage Manager Uninstalling MD Storage Manager From Windows Uninstall MD Storage Manager From Microsoft Windows Operating Systems Other Than Microsoft Windows Server 2008 Use the Ch.
Uninstalling MD Storage Manager From Linux By default, PowerVault MD Storage Manager is installed in the /opt/dell/mdstoragemanager directory. If another directory was used during installation, navigate to that directory before beginning the uninstallation procedure.
7 Appendix — Manual Configuration Of iSCSI The following sections contain step-by-step instructions for configuring iSCSI on your storage array. However, before beginning, it is important to understand where each of these steps occur in relation to your host server or storage array environment.
You can discover the storage array either automatically or manually. Automatic Storage Array Discovery 1. Launch MD Storage Manager . If this is the first storage array to be set up, the Add New Storage Array window is displayed. 2. Select Automatic and click OK .
Task Purpose degrades or fails, or an adverse environmental condition occurs. Configure a storage array To create virtual disks and map them to hosts. Step 2: Configure The iSCSI Ports On The Storage Array By default, the iSCSI ports on the storage array are set to the following IPv4 settings: Controller 0, Port 0: IP: 192.
3. Under Target Portals , click Add and enter the IP address or DNS name of the iSCSI port on the storage array. 4. If the iSCSI storage array uses a custom TCP port, change the Port number. The default is 3260. 5. Click Advanced and set the following values on the General tab: – Local Adapter — Must be set to Microsoft iSCSI Initiator.
d) Save and close the /etc/iscsi/iscsid.conf file. 5. From the console, restart the iSCSI service with the following command: service iscsi start 6. Verify that the iSCSI service is running during boot using the following command from the console: chkconfig iscsi on 7.
Mutual CHAP In addition to setting up target CHAP, you can set up mutual CHAP in which both the storage array and the iSCSI initiator authenticate each other. To set up mutual CHAP, configure the iSCSI initiator with a CHAP secret that the storage array must send to the host sever in order to establish a connection.
CHAP Setting Description CHAP If CHAP is selected and None is deselected, the storage array requires CHAP authentication before allowing access. 2. To configure a CHAP secret, select CHAP and select CHAP Secret . 3. Enter the Target CHAP Secret (or Generate Random Secret ).
The iSCSI port you configured on the storage array during target discovery disappears. 6. Under Target Portals , click Add and re-enter the IP address or DNS name of the iSCSI port on the storage array (removed above).
3. If you are using Mutual CHAP authentication, you can set the user name and password for CHAP authentication of the target(s) by the initiator by editing the following lines: node.session.auth.username_in=<iscsi_target_username> node.session.auth.
Step 7: Connect To The Target Storage Array From The Host Server For Windows Server 2008 GUI Version 1. Click Start → Program → Microsoft iSCSI Initiator or Start → All Programs → Administrative Tools → iSCSI Initiator. 2. Click the Targets tab.
TCP_Port_Number_Of_Target_Portal * * * Login_Flags * * * * * Username Password Authtype * Mapping_Count where – <Target_Name> is the target name as displayed in the target list. Use the iscsicli ListTargets command to display the target list. – <Report_To_PNP > is T, which exposes the LUN to the operating system as a storage device.
Step 8: (Optional) Set Up In-Band Management Out-of-band management (see Step 1: Discover the Storage Array (Out-of-band Management Only) ) is the recommended method for managing the storage array. However, to optionally set up in-band management, use the steps shown below.
8 Appendix — Using Internet Storage Naming Service Internet Storage Naming Service (iSNS) server, supported only on Microsoft Windows iSCSI environments, eliminates the need to manually configure each individual storage array with a specific list of initiators and target IP addresses.
46.
9 Appendix — Load Balancing Windows Load Balance Policy Multi-path drivers select the I/O path to a virtual disk through a specific RAID controller module. When the multi-path driver receives a new I/O, the driver tries to find a path to the current RAID controller module that owns the virtual disk.
The Computer Management window is displayed. 2. Click Device Manager to show the list of devices attached to the host. 3. Right-click the multi-path disk device for which you want to set load balance policies, then select Properties . 4. From the MPIO tab, select the load balance policy you want to set for this disk device.
Figure 6. Initiator Configuration Two sessions with one TCP connection are configured from the host to each controller (one session per port), for a total of four sessions. The multi-path failover driver balances I/O access across the sessions to the ports on the same controller.
50.
10 Appendix — Stopping And Starting iSCSI Services In Linux To manually stop the iSCSI services in Linux, certain steps must be followed to maintain parallel processing between the storage array and the host server. 1. Stop all I/O. 2. Unmount all correlated file systems.
52.
11 IPv4 Settings — Worksheet NOTE : If you need additional space for more than one host server, use an additional sheet. Static IP address (host server) Subnet (should be different for each NIC) Default gateway iSCSI port 1 ___ . ___ . ___ . ___ ___ .
Static IP address (host server) Subnet Default gateway iSCSI port 1, In 0 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ iSCSI port 1, In 1 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ Management port cntrl 1 ___ .
12 IPv6 Settings — Worksheet NOTE : If you need additional space for more than one host server, use an additional sheet. Host iSCSI port 1 Host iSCSI port 2 Link local IP address ___ . ___ . ___ . ___ Link local IP address ___ . ___ . ___ . ___ Routable IP address ___ .
Router IP address ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ iSCSI controller 0, In 1 IP address FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ Routable IP address 1 ____ : ____ : __.
Een belangrijk punt na aankoop van elk apparaat Dell MD3660I (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dell MD3660I heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dell MD3660I vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dell MD3660I leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dell MD3660I krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dell MD3660I bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dell MD3660I kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dell MD3660I . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.