Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Before You Begin Consider the following best practices before setting up your SCv2000/SCv2020 storage system. • Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iSCSI storage system. • Complete the Worksheet to Record System Information in this guide before configuring the storage system.
Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition.
Worksheet to Record System Information Use the following worksheet to record the information that is needed to install the SCv2000/SCv2020 storage system . Storage Center Information Gather and record the following information about the Storage Center network and the administrator user.
IPv4 address for storage controller module 1: port 1 ___ . ___ . ___ . ___ IPv4 address for storage controller module 2: port 1 ___ . ___ . ___ . ___ (Four port I/O card only) IPv4 address for storage controller module 1: port 3 ___ . ___ . ___ . ___ (Four port I/O card only) IPv4 address for storage controller module 2: port 3 ___ .
Table 6. Physical WWNs in Fault Domain 1 Physical WWN of storage controller 1: port 1 ________________ Physical WWN of storage controller 2: port 1 ________________ (Four port I/O card only) Physical WWN of storage controller 1: port 3 ________________ (Four port I/O card only) Physical WWN of storage controller 2: port 3 ________________ Table 7.
• The Dell Storage Center Dell Storage Client Administrator’s Guide describes how to use the Dell Storage Client to manage a Storage Center. Installation and Configuration Before you begin install.
Figure 2. Hole Locations in Rack 1. Middle hole of top 1U 2. Top hole of bottom 1U 3. Bottom hole of bottom 1U 6. Slide the storage system chassis onto the rails. Figure 3. Mount the SCv2000/SCv2020 Storage System Chassis 7. Secure the storage system chassis to the rack using the mounting screws within each chassis ear.
Figure 4. Front Bezel 2. Insert the left end of the bezel into the securing slot until the release latch snaps into place. 3. Secure the bezel with the keylock. Front-End Cabling Front-end cabling refers to the connections between the storage system and host servers.
3. Connect fault domain 2 to switch 2. a. Connect a cable from storage controller 1: port 2 to switch 2. b. Connect a cable from storage controller 2: port 2 to switch 2. c. (Four-port I/O card only) Connect a cable from storage controller 1: port 4 to switch 2.
a. Connect a SAS cable from storage controller 1: port 4 to server 4. b. Connect a SAS cable from storage controller 2: port 4 to server 4. Figure 6. Storage System Connected Directly to Host Servers 1. Server 1 2. Server 2 3. Server 3 4. Server 4 5. SCv2000/SCv2020 storage system 6.
Figure 7. Storage System Connected to a Management Network 1. Management network switch 2. SCv2000/SCv2020 storage system 3. Storage controller 1 4. Storage controller 2 Back-End Cabling An SCv2000/SCv2020 storage system can be deployed with or without SC100/SC120 expansion enclosures .
NOTE: In an SCv2000/SCv2020 storage system, the top storage controller is storage controller 1 and the bottom storage controller is storage controller 2.
Figure 10. Power Cables 3. Secure each power cable to the storage system chassis using the strain relief fasteners. 4. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
NOTE: To discover and configure a Storage Center, the software must be installed on a host server that is located on the same subnet as the storage system 3. Start the software by double-clicking the Enterprise Manager Client shortcut. The Dell Storage Client welcome screen appears.
Storage Connectivity Configurations Storage Center supports up to 168 drives in one redundant-path SAS chain • An SCv2000 supports up to 13 SC100 expansion enclosures or 6 SC120 expansion enclosures.
Power Supplies AC power supply (per power supply) Wattage 580 W (maximum wattage: 584 W) Voltage 100–240 VAC (7.6–3.0 A) Heat dissipation SCv2000 : 65 W at 230 VAC and 99 W at 115 VAC SCv2020 : 65.
Environmental Maximum vibration Operating 0.21 G at 5–500 Hz for 15 min Storage 1.04 G at 2–200 Hz for 15 min Maximum shock Operating Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- .
Een belangrijk punt na aankoop van elk apparaat Dell SCv2000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Dell SCv2000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Dell SCv2000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Dell SCv2000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Dell SCv2000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Dell SCv2000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Dell SCv2000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Dell SCv2000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.