DA T ASHEET DS_S48SA1R812_06 012006 Delta Electronics, Inc. Delphi Series S48SA, 33W Family DC/DC Power Modules: 48V in, 1.8V/12A out The Delphi Series S48SA, surface mountable, 48V input, single output, isolated DC/DC converter is the latest offeri ng from a world leader in power system and technology and manu facturing – Delta Electronics, Inc.
DS_S48SA1R812_06012 006 TECHNICAL SPECIFICATIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal Vou t unless otherwise noted.) PARAMETER NOTES and CONDITIONS S48SA1R812NRFA Min.
DS_S48SA1R812_06012 006 ELECTRICAL CHARACTERISTICS CURVES 55 60 65 70 75 80 85 90 95 12 345 67 89 1 0 1 1 1 2 O U TPU T C U R R E N T (A ) E FFICIE NCY ( % ) 36Vin 48Vin 75Vin 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 123456 789 1 0 1 1 1 2 O UT PUT CU RRE NT (A ) P O WE R DIS S IP A TIO N ( W) 36Vin 48Vin 75Vin Figure 1: Efficiency vs.
DS_S48SA1R812_06012 006 4 ELECTRICAL CHARACTERISTICS CURVES Figure5 : Turn-on transie nt at zero load current (1 ms/div). Top Trace: Vout (500mV/div); Bottom Trace: ON/OFF Control (5V/div). Figure 6: Output voltage response to step-change in load current (50%-75% of Io, max; di/dt = 0.
DS_S48SA1R812_06012 006 ELECTRICAL CHARACTERISTICS CURVES Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 9 : Input Reflected Ripple Current, i s , at full rated output current and nominal i nput voltage with 12 µ H source impedance and 33 µ F electrolytic capacito r (2 mA/div).
DS_S48SA1R812_06012 006 This power module is not internally fused. To a chieve optimum safety and system protection, an input line fuse is highly recommended. T he safety agencies require a normal-blow fuse with 3A maximum rating to be installed in the ungrounded le ad.
DS_S48SA1R812_06012 006 Vo(+) Vi(+) Vo(-) Sense(-) Sense(+) Vi(-) ON/OFF Figure 13: Remote on/off implementation Remote Sense (Optional) Remote sense compensates for voltage drop s on the output by sensing the actual output voltage at the p oint of load.
DS_S48SA1R812_06012 006 [] ΚΩ − ∆ = − 104 % Vo up − ∆ + 1089 %) 100 ( 8 . 23 Vo Ex. When trim-up +10% (1.8V X 1.1 = 1.98V) Rtrim [] ΚΩ = − = − 9 .
DS_S48SA1R812_06012 006 9 THERMAL CONSIDERATIONS Thermal management is an im porta nt part of the system design. To ensure proper, reliable operation, sufficie nt cooling of the power module is neede d over the entire temperature range of the modul e.
DS_S48SA1R812_06012 006 10 PICK AND PLACE LOCATION SURFAC E-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD).
DS_S48SA1R812_06012 006 Temp . Time 150 ℃ 200 ℃ 100~140 sec. T ime Limited 9 0 sec. above 217 ℃ 217 ℃ Preheat time Ramp up max. 3 ℃ /sec. Ramp down max. 4 ℃ /s ec. Peak Tem p . 240 ~ 245 ℃ 25 ℃ Note: The temperature refers to the pin of S48SA, measured on the pin +Vout joint.
DS_S48SA1R812_06012 006 MECHANICAL DRAWING SMD Through-Hole Pin No. Name Function 1 +Vout Positive output voltage 2 -Vout Negative output voltage 6 Trim Output voltage trim 8 ON/OFF ON/OFF logic 11 -V.
DS_S48SA1R812_06012 006 14 PART NUMBERING SYSTEM S 48 S A 1R8 12 N R F A* Form Factor Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Type Option Code S- Small Power 48V S- Single A- Advanced 1R2-1.2V 1R5-1.
Een belangrijk punt na aankoop van elk apparaat Delta Electronics Series S48SA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Delta Electronics Series S48SA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Delta Electronics Series S48SA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Delta Electronics Series S48SA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Delta Electronics Series S48SA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Delta Electronics Series S48SA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Delta Electronics Series S48SA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Delta Electronics Series S48SA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.