Delphi Series S48SP , 35W 1x1 Brick DC/DC Power Modules: 48V in, 3.3V/10A out The Delphi Series S48SP , 1x1 Brick, 48V input, single output, isolated DC/DC converters a re the latest of fering from a world leader in p ower systems technology and manufacturi ng ― Delt a Electronics, Inc.
DS_S48SP3R310_05222008 2 TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V ou t unless otherwise no ted.) PA R A M E T E R NOTES and CONDITIONS S48SP3R310 (St andard) Min.
DS_S48SP3R310_05222008 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Ef ficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C Figure 2: Power dissipation vs. load current for min imum, nominal, and max imum input voltage at 25°C.
DS_S48SP3R310_05222008 4 ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient at full rated loa d current (5 ms/div ). Vin=48V . T op T race: V out, 1. 0V/div; Bottom T race: ON/OFF input, 2V/div Figure 5: T urn-on transient at zero load current (5 ms/div).
DS_S48SP3R310_05222008 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (75%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF tantalum cap acitor and 1 µF ceramic capacitor . T op T race: Vout (100mV/div , 50us/div ) , Bottom T race: Iout (2A/div).
DS_S48SP3R310_05222008 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at nominal input voltage an d rated load current (20 mA/div.
DS_S48SP3R310_05222008 7 The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
DS_S48SP3R310_05222008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload.
DS_S48SP3R310_05222008 9 FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment To increase or decrea se the output voltage set poi nt, the modules may be connected wit h an external resistor between the TRIM pin and either the Vo (+) or Vo(-). The TRIM pin should be left open if this feature is not used.
DS_S48SP3R310_05222008 10 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_S48SP3R310_05222008 11 PICK AND PLACE LOCA TION SURF ACE-MOUNT T APE & REEL RECOMMENDED P AD LA YOUT (SMD).
DS_S48SP3R310_05222008 12 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T i me ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
DS_S48SP3R310_05222008 13 MECHANICAL DRA WING Surface-mount module Through-Hole module Pin No. Name Function 1 2 3 4 5 6 +Vin -Vin ON/OFF (Optional) -V out TRIM (Optional) +V out Positive input voltag.
DS_S48SP3R310_05222008 14 P ART NUMBERING SYSTEM S 48 S P 3R3 10 N R F B Product Ty p e Input V olt age Number of Output s Product Series Output Vo l t a g e Output Current ON/OFF Logic Pin Length/T ype Option Co de S - Small Power 48- 36V~75V S - Single 1x1, 10A 3R3 - 3.
Een belangrijk punt na aankoop van elk apparaat Delta Electronics Series S48SP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Delta Electronics Series S48SP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Delta Electronics Series S48SP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Delta Electronics Series S48SP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Delta Electronics Series S48SP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Delta Electronics Series S48SP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Delta Electronics Series S48SP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Delta Electronics Series S48SP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.