Gebruiksaanwijzing /service van het product VSGF36NRA van de fabrikant Desa
Ga naar pagina of 40
For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
www .desatech.com 1 16746-01A 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier .
www .desatech.com 1 16746-01A 3 SAFETY INFORMA TION W ARNING: This product con- ta ins an d/o r gen er ate s c hem ical s known to the state of California to cause cancer or birth defects or other reproductive harm.
www .desatech.com 1 16746-01A 4 1. This appliance is only for use with the type of gas indica ted on the rating plate. Thi s appli ance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).
www .desatech.com 1 16746-01A 5 Optional Remote Control PRODUCT IDENTIFICA TION Figure 1 - Log Base Assembly (VSGF36NRA Shown) Log Set Base Assembly Front Burner Piezo Ignitor Rear Burner T op Louver .
www .desatech.com 1 16746-01A 6 LOCA TING FIREBO X PLANNING Plan where you will install the firebox. This will save time and money later when you install the firebox. Before installation, consider the following: 1. Where the firebox will be located.
www .desatech.com 1 16746-01A 7 AIR FOR COMB USTION AND VENTILA TION W ARNING: This firebox shall not be installed in a confined space or unusually tight con - struction unless provisions are provided for adequate combus- tion and ventilation air .
www .desatech.com 1 16746-01A 8 AIR FOR COMB USTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION Determining if Y ou Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
www .desatech.com 1 16746-01A 9 VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining un - confined space.
www .desatech.com 1 16746-01A 10 CAUTION: This fireplace cre- ates warm air currents. These currents move heat to wall sur - faces next to fireplace.
www .desatech.com 1 16746-01A 1 1 INST ALLA TION Continued Mantel Clearances for Built-In Installation If placing custom mantel abov e built-i n firebox, you mus t meet the minim um allow able clea ranc e betw een man tel shel f and top of firebox op enin g sh ow n in Fig ure 7.
www .desatech.com 1 16746-01A 12 Rough Opening Dimensions for Built-in Installation Front Width (Inside to Depth Model Inside) Height (Minimum) 36" 41 1 / 2 " 40 1 / 2 " 20 3 / 4 " 1. Fr am e in rou gh op en in g. The fire box fra mi ng sh oul d be co nst ruc ted of 2 x 4 lu mb er or hea vie r.
www .desatech.com 1 16746-01A 13 INST ALLA TION Continued INST ALLING FIREBOX USING OPTIONAL ACCESSORY MANTELS W ARN ING : A q ual ified s er vic e person must install firebox. Fol- low all local codes. This firebox may be installed using the corner or cab inet mant el with heart h base acces sori es again st a wall in your home.
www .desatech.com 1 16746-01A 14 INST ALLA TION Continued W ARNING: Never connect natural gas fireplace to private (non-utility) gas wells . This gas is commonly known as wellhead gas. Installation Items Needed Before installing fireplace, make sure you have the items listed below .
www .desatech.com 1 16746-01A 15 Note: If adding the G8007 series brick liner acces- sory , install it now . Follow instructions in G8007 accessory kit. CAUTION: Do not pick up log base assembly by burner . This could damage burner . Only handle base by grates.
www .desatech.com 1 16746-01A 16 CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections, inter nal and external to unit, for leaks after insta lling or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak.
www .desatech.com 1 16746-01A 17 INST ALLA TION Continued INST ALLING LOGS (MODELS VSGF36NT A, VSGF36PT A, VSGF36NRA AND VSGF36PRA) W ARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved wit h this hea ter may result in property damage or per son al i nju ry.
www .desatech.com 1 16746-01A 18 INST ALLA TION Continued INST ALLING FIREPLACE HOOD AND SCREEN 1. Loosen screws inside top edge of firebox. Slide notches in hood over screws and tighten screws (see Figure 25). 2. Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 26).
www .desatech.com 1 16746-01A 19 OPERA TING FIREPLACE THERMOST A T MODELS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a fire or explosion may result causing property damage, per - sonal injury or loss of life.
www .desatech.com 1 16746-01A 20 OPERA TING FIREPLACE Continued Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. T o light pilot with match, see Manual Lighting Procedure .
www .desatech.com 1 16746-01A 21 OPERA TING FIREPLACE Continued C. Use only your hand to push in or turn the gas contr ol knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier .
www .desatech.com 1 16746-01A 22 OPERA TING FIREPLACE Continued WA RN ING : Mak e su re t he se- l ec to r s wi tc h is i n t h e O FF p os it io n wh en yo u ar e a way fr om ho me fo r lo ng per iod s of ti me . He ate r wi ll c om e o n a u to ma ti ca ll y wi th s el e c- to r s wit ch in the ON po sit ion .
www .desatech.com 1 16746-01A 23 OPERA TING FIREPLACE Continued Figure 32 - Setting the Selector Switch, Control Knob and Flame Adjustment Knob for Hand-Held Remote Operation O F F P I L O T L O I H R.
www .desatech.com 1 16746-01A 24 OPERA TING FIREPLACE Continued 2. The receiver continuously receives signals from the hand-held remote to control the roo m tempera ture . If the hand-held remot e is misplaced, obstructed or for any r eason cannot transmi t to the receiv er , the rec eiver will shut off the fireplace after 8 minutes.
www .desatech.com 1 16746-01A 25 CLEANING AND MAINTENANCE W ARNING: T urn off fireplace and let cool before cleaning. CAUTION: Y ou must keep control areas, burner and cir- culating air passageways of fireplace clean. I nspect these areas of fireplace before each use.
www .desatech.com 1 16746-01A 26 WIRING DIAGRAM Not e: For prope r operat ion of optio nal acce ssor ies , the wires from the thermopile to the control must be connected exactly as shown. Thermopile SPECIFICA TIONS Models VSGF36NT A and VSGF36NRA Btu (V ariable) 33,000/21,500 T ype Gas Natural Gas Ignition Piezo Pressure Manifold 3.
www .desatech.com 1 16746-01A 27 POSSIBLE CAUSE 1 . Ignitor electrode not con - nected to ignitor cable 2. Ignitor cable pinched or wet 3. Piezo ignitor nut is loose 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong 1.
www .desatech.com 1 16746-01A 28 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Co nt rol k nob n o t fu ll y pr es se d in 2. Control knob not pressed in long enough 3. Equipment shutoff valve not fully open 4. Pilot flame not touching ther - mocouple, which allows ther - mocouple to cool, causing pilot flame to go out.
www .desatech.com 1 16746-01A 29 POSSIBLE CAUSE 1. Not enough air 2. Gas regulator defective 3. Residues from manufacturing processes and logs curing 1. Not enough combustion/ven - tilation air 1. Turning control knob to HI position when burners are cold 2.
www .desatech.com 1 16746-01A 30 POSSIBLE CAUSE 1. Heater burning vapors from pa in t, ha ir sp ra y , g lues , cl ea ne rs , ch em ic al s, ne w car pe t, et c. (S ee IM PO R T ANT s ta te men t a bo ve ) 2. Low fuel supply (propane/LP only) 3. G a s l e a k .
www .desatech.com 1 16746-01A 31 ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Purcha se these firebox accessorie s from your local dealer . If they can not supply these accessories, call DESA ʼ s Sales Department at 1-866-672-6040 for information.
www .desatech.com 1 16746-01A 32 ILL USTRA TED P ARTS BREAKDOWN MODELS VSGF36PT A, VSGF36NT A L PG 19 21 22 23 24 17 14 14 16 13 12 27 28 29 2 1 1 5 4 3 7 9 10 10 8 6 1 18 20 26 16 15 25.
www .desatech.com 1 16746-01A 33 P ARTS LIST This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY P ART NUMBER NO. VSGF36PT A VSGF36NT A DESCRIPTION QTY .
www .desatech.com 1 16746-01A 34 ILL USTRA TED P ARTS BREAKDOWN MODELS VSGF36PRA, VSGF36NRA L PG 25 19 21 17 14 14 16 13 12 30 31 32 2 1 1 5 4 3 7 9 10 10 8 6 1 18 24 26 27 20 22 23 29 16 15 28.
www .desatech.com 1 16746-01A 35 P ARTS LIST This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY P ART NUMBER NO. VSGF36PRA VSGF36NRA DESCRIPTION QTY .
www .desatech.com 1 16746-01A 36 ILL USTRA TED P ARTS BREAKDOWN MODELS VSGF36PT A, VSGF36NT A, VSGF36PRA AND VSGF36NRA 1 4 8 7 6 27 9 10 28 29 30 1 1 12 22 18 25 26 20 17 21 19 16 15 13 5 2 3 14 23 24.
www .desatech.com 1 16746-01A 37 KEY P ART NO. NUMBER DESCRIPTION QTY . 1 1 13190-01CK Screen 2 2 1 16865-01CK Bottom Louver Assembly 1 3 ** Face W eldment 1 4 101355-03CK Hood 1 5 1 16864-01CK Louver.
www .desatech.com 1 16746-01A 38 _____________________________________________________ ______________________________________________________ ______________________________________________________ ___.
www .desatech.com 1 16746-01A 39 _____________________________________________________ ______________________________________________________ ______________________________________________________ ___.
LIMITED WARRANTY VENT -FREE GAS FIREPLACE SY STEM DESA Heating Products warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Een belangrijk punt na aankoop van elk apparaat Desa VSGF36NRA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Desa VSGF36NRA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Desa VSGF36NRA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Desa VSGF36NRA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Desa VSGF36NRA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Desa VSGF36NRA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Desa VSGF36NRA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Desa VSGF36NRA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.