Nailer/Stapler Operation Manual MG-NS2X4A 7/16/99 This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. PLEASE READ THIS MANUAL. DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 Specifications MODEL NO.
PAGE 2 Page Tool Specifications ................................................................ Front Cover Table of Contents ................................................................................... 2 Limited Warranty .....................
PAGE 3 All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user).
PAGE 4 HAZARD TO LOOK FOR Compressed Gas Excessive Operating Pressure Unsuitable Cleaning Solvents WHAT COULD HAPPEN Oxygen will react with oil in tool caus- ing an explosion. Flammable gases will ignite from sparking and cause the tool to explode, resulting in serious injury or death.
PAGE 5 Risk of head injury. WHAT COULD HAPPEN Metal fragments, fasteners, or other material could be projected against head or into eyes resulting in serious injury or property damage. Contin- ued exposure to an operating tool can result in permanent hearing dam- age.
PAGE 6 Risk from flying objects. WHAT COULD HAPPEN Fasteners could ricochet or be propelled causing serious injury or property damage. When working along edges or next to voids in work surface, the co.
PAGE 7 Do not store the tool in cold weather. Frost or ice can form on the operating valves or mechanisms and the tool may not operate correctly. In cold weather operation (near or below freezing), DO NOT USE a permanent antifreeze such as ethylene glycol for a cold weather lubricant.
PAGE 8 Always connect the Female Quick Cou- pler to the air hose. Never connect the Female Quick Coupler to the tool. Never carry the tool by the hose or pull the hose to move the tool or a com- pressor. Keep hoses away from heat, oil, and sharp edges.
PAGE 9 NAILER FEMALE QUICK COUPLER MALE QUICK CONNECTOR OILER FILTER RECOMMENDED HOOK-UP The following illustration shows the proper hook-up which will help prolong the life of the Tool.
PAGE 10 OPERATING A CONTACT TRIP TOOL: 1. Requires finger to be off the trigger and the nose of the Tool to be placed on the work surface. 2. The contact trip safety mechanism is then depressed against the work surface and the trigger pulled to drive a fastener.
PAGE 11 Handle the tool carefully. Respect the tool as a working implement and always as- sume the tool contains fasteners: a. Never use the tool as a toy and engage in horseplay. b. Never aim or point the tool at any- one. The tool may contain fasteners.
PAGE 12 4. Push release button (if equipped) and slide feeder shoe forward. Protect your eyes and ears. Wear Z87 safety glasses with side shields. Wear hearing protection. Employers and users are responsible for ensuring the user or anyone near the tool uses the prescribed safety equipment.
PAGE 13 Disconnect tool from air compressor before adjusting, clearing jams, servicing, relocating and during non-operation. FASTENER JAMMED IN FASTENER DISCHARGE AREA: 1. Disconnect tool from air hose. 2. NF2502X4, NB1252X4, NB2002X4, NBSNC2X4 Release the magazine latch to open the magazine.
PAGE 14 FASTENER JAM INSIDE MAGAZINE : 1. Disconnect tool from air hose. 2. NF2502X4, NB1252X4, NB2002X4, NBSNC2X4 Release the magazine latch to open the magazine. Feeder Magazine Latch SNC1002x4 Pull feeder shoe back into "locked" position.
PAGE 15 PROBLEM Air leaking at trigger valve area. Air leaking through the exhaust deflector. Tool fails to drive fastener. Tool runs slow or has loss of power. SOLUTION Seals must be replaced & operation of Contact trip must be checked. On the NBSNC2x4 contact *AWSC for correct part.
PAGE 16 SOLUTION Replace feed pawl. Contact an *AWSC Replace feed pawl spring. Fasteners recommended for tool must be used. Replace with undamaged fasteners. Set platform to correct height. Adjust air pressur e to the correct PSI for that particular model nailer/stapler .
PAGE 17 NF2502X4 1/4" NPT INLET PLUG (AC100) FINISH NAIL FASTENERS 6 & 7MM COMBINATION CRESCENT WRENCH 3 4 5mm ALLEN WRENCHES FINISH NAILER LUBRICATING OIL SAFETY GLASSES 1 1 / 2 ” 1 ” 1 .
PAGE 18 SNC1002X4 NARROW CROWN STAPLE FASTENER 1/4" NPT INLET PLUG (AC100) LUBRICATING OIL NARROW CROWN STAPLER 3 & 4 ALLEN WRENCHES SAFETY GLASSES Tool 2X4 Part Number Description Qty per Bo.
PAGE 19 NB2002X4 LUBRICATING OIL 1/4" NPT INLET Plug (AC100) BRAD NAILER BRAD NAIL FASTENERS 4 3 ALLEN WRENCHES 5/8" SAFETY GLASSES Tool 2X4 Part Number Description Qty per Box Steel Driver .
PAGE 20 NB1252X4 LUBRICATING OIL 1/4" NPT INLET PLUG (AC100) BRAD NAIL FASTENERS BRAD NAILER 4MM 3MM ALLEN WRENCHES SAFETY GLASSES Tool 2X4 Part Number Description Qty per Box Steel Driver Series.
PAGE 21 NBSNC2X4 2X4 SIGNATURE SAFETY GLASSES LUBRICATING OIL 4MM 3MM ALLEN WRENCHES COMBINATION BRAD NAILER/ NARROW CROWN STAPLER NARROW CROWN STAPLE & BRAD NAIL FASTENERS 1/2" 3/4" 1&q.
PAGE 22 REP AIR KITS A V AILABLE K-0521 T op Repair Kit K-0522 Bottom Repair Kit NF2502X4 K-1664 Driver Blade Kit K-0523 T rigger Repair Kit SNC1002X4 and NB1252X4 K-0525 T op Repair Kit K-0526 Bottom.
PAGE 23 REP AIR KITS A V AILABLE K-0517 T op Repair Kit K-0518 Bottom Repair Kit NB2002X4 K-1850 Driver Blade Kit K-0519 T rigger Repair Kit NBSNC2X4 B340-06 T op Repair Kit B232-23 Bottom Repair Kit .
Nailer/Stapler Operation Manual Call our T oll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service Center for ordering r epair parts and for warranty repairs.
Een belangrijk punt na aankoop van elk apparaat DeVillbiss Air Power Company 2by4 Contractor Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen DeVillbiss Air Power Company 2by4 Contractor Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens DeVillbiss Air Power Company 2by4 Contractor Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding DeVillbiss Air Power Company 2by4 Contractor Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over DeVillbiss Air Power Company 2by4 Contractor Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van DeVillbiss Air Power Company 2by4 Contractor Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de DeVillbiss Air Power Company 2by4 Contractor Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met DeVillbiss Air Power Company 2by4 Contractor Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.