Gebruiksaanwijzing /service van het product A100 van de fabrikant Eagle Electronics
Ga naar pagina of 16
EA GLE I n s t a l l a t i o n, Op er a t i on an d M a in t en an c e I n s tru c ti o ns EA G L E M O D E L A 1 00 A N S I P U M P S Lubrication information is in Section III-A, Item 1b.
2 SECTION I—GENERAL Introduction ................................................................................................................................................................. 3 I-A Importance of Instructions .....................
3 Introduction This instruction manual is intended to assist those involved with the installation, operation and maintenance of Eagle Model A100 pumps. It is recommended that this manual be thoroughly reviewed prior to installing or performing any work on the pump or motor .
4 II-C. Lev eling and Gr outing of Baseplate Initial Alignment Chec k 1. Put the unit in place on wedges located at four points as shown in F ig . 2. Some long installations may require additional wedges near center of bedplate. 2. Adjust wedges to level unit (appro ximately), placing unit between ” and 1” above foundation.
5 PRIOR TO COUPLING DRIVER TO PUMP , ROT A TION OF DRIVER SHOULD BE CHECKED! Serious damage can result if pump is rotated in wrong direction. Once motor rotation is checked, connect coupling , following the manufacturer ’s instructions. If a coupling guard is furnished with the unit, ensure that it is securely fastened in place.
6 b. A high quality turbine type oil with rust and oxidation inhibitors should be used. Under normal operating conditions, an oil of 300 SSU viscosity at 100° F . (approximately SAE 20) should be used. Fill oiler bottle and replace in oiler housing .
7 SECTION V— DISA SSEMBL Y AND RE ASSEMBL Y V -A. Disassembly (refer to Sectional V iews in Part VI) 1. Prepare pump for disassembly as follows: a. Lock out power supply to motor . b. Shut off valves controlling flow to and from pump. c. Flush pump of all corrosive or toxic liquid, if required.
8 4. On S, M and L models, insert retaining ring (361A) into groove in bearing housing (134A). Flat side of retaining ring must be against bearing (112A). On X units, slide bearing end cover (109A) and gasket (360C) on shaft. Ensure the “top ” of end cover (109A) lines up with the “top ” of bearing housing (134A), check scribe marks.
9 13. Place casing gasket (351) against shoulder in casing . 14. Slide the pullout assembly into the casing (100). Drain slot in stuffing box cover (184) should line up with drain connection in casing. Install frame–to–casing bolts (370) and tighten evenly while rotating shaft (122) by hand.
10 101 106 1 12A 126 168A 261 332A 333A 351 360C 360D 412A 469D 496 1 1 set 1 1 1 1 1 1 1 1 1 1 1 1 Impeller Stuffing Box Packing (2) Ball Bearing-Outboard.
11 Mod el A 1 0 0 S, M, L Ass embl y Vie w of 8” P umps Only 100 239 105 106 412A 469D 101 351 122A 355 353 107 333A 370D 1 13A 496 361A 168A 123 210 261 126 370H 184 370 228A 1 12A 134A 332A 136 &a.
12 Mod el A 1 0 0 M, L 132 370 184 168A 360D 496 108 107 355 353 123 113A 228A 370C 134A 136 & 382 332A 112A 370D 361A 370E 370H 126 122A 210 333A 106 370F 131 239 105 469D 412A 106 101 351 100.
13 Mod el A 1 0 0 X 101 412A 469D 106 105 184 351 100 370H 239 355 107 370 370E 131 228A 370F 106 333A 469B 353 1 13A 168A 123 261 126 108 210 132 122A 360D 370D 371C 109A 332A 136 & 382 496A 134A.
14 Causes & Corrective Measures 1. Pump not primed or properly vented—check that casing and suction pipe are completely filled with liquid. 2. Speed too low—check whether motor wiring is correct and receives full voltage or turbine receives full steam pressure.
15 SEC T ION VII I — ORDERI NG SP ARE P ARTS VIII-B. Instr uctions for Ordering Spar e Par ts Repair orders will be handled with the minimum of delay if the following directions are followed: 1. Give model number , size of pump, and serial number . These can be obtained from the nameplate on the pump.
EA GLE EA GL E P UMP & C OM P RE SSO R L T D . 7025 - 5 Street S.E., Calgar y , AB T2H 2G2 Canada ANSI Centrifugal Pumps Multistage Horizontal Pumps V er tical Sump Pumps R otar y Scr ew Compr essor Air/Gas Dr yers www .
Een belangrijk punt na aankoop van elk apparaat Eagle Electronics A100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Eagle Electronics A100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Eagle Electronics A100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Eagle Electronics A100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Eagle Electronics A100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Eagle Electronics A100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Eagle Electronics A100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Eagle Electronics A100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.