E at o n ePDU D at a C e nt e r P r odu c t Cat alo g P ow er distribution solutions S w it c h N to E ato n ..
EA TON C ORPORA TION Enclosure Power Distribution Units 2.
T able of C ontent s eaton.com/epdu 1.800.356.5794 3 T able of contents Product Line Overview . ...........................................................................................................................................................
EA TON C ORPORA TION Enclosure Power Distribution Units 4 Broad product portfolio Eaton offers the largest selection of rack mounted power distribution units available on the market, we call these Eaton ® ePDUs ® . Our complete suite of products is designed specifically to help you meet rapidly escalating requirements.
C hoosing ePDU T echnolog ies Eaton ePDU catalog numbering system Eaton’ s smart style numbers help you understand our numbering system. Follow the example below to see what the letters and numbers mean within this ePDU catalog. Please note that this numbering scheme represents the majority of our part numbers, but not all.
ePDU T echnolog ies ePDU technologies Eaton’ s ePDU technologies satisfy the demand of every data center . Eaton ePDUs offer single and dual chassis, five technology options, the broadest power range in the market and the ability to manufacture custom ePDUs.
Under s t a ndi ng ePDU T echnolog ies eaton.com/epdu 1.800.356.5794 7 Basic (BA) – rugged construction and flexible mounting options (page 10) Designed for reliable and cost effective power distribution, Basic ePDUs have the form factor and receptacle choices to meet the needs of the demanding data center architect.
Under s t a ndi ng ePDU T echnolog ies EA TON C ORPORA TION Enclosure Power Distribution Units 8 Why monitor? The unique monitoring function of Eaton ePDUs allows you to remotely monitor the current draw of individual outlets or sections over a network.
ePDU Sof t w a re Opt ions eaton.com/epdu 1.800.356.5794 9 ePDU software management Eaton offers a number of software management tools for you based on the number of ePDUs you need to manage. Web Browser / E-mail Alerts Every network connected ePDU comes standard with built in web server and e-mail alert capability .
EA TON C ORPORA TION Enclosure Power Distribution Units 10 Basic ePDUs Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) ePBZ98 ePBZ98 5-15P 15A 1.44 BA 6 0U (18) 5-15R 48 x 1.5 x 1.
www .epdu.com 1.800.356.5794 11 Basic ePDUs ePBZ89 ePBZ93 PW314BA0U253 PW306BA0U246 PW105BA0U239 ePBZ97.
EA TON C ORPORA TION Enclosure Power Distribution Units 12 Basic ePDUs Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101BA1U140 T982A1-N-SS-009 5-15P (1) 15A 1.44 BA 9 1U (12) 5-15R 1.
www .epdu.com 1.800.356.5794 13 Basic ePDUs ePBZ99 ePBZ95 ePBZ94 ePBZ88 PW105BA1U163 Front view Rear view PW314BA1U193 Front view Rear view PW101BA1U140 Front view Rear view.
EA TON C ORPORA TION Enclosure Power Distribution Units 14 F le xPDUs a nd Hot S wa p Ma i ntena nc e Bypass Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) EFLX1500R-PDU1U 58015 5-15P None 1.
F le xPDUs a nd HotS wa p Ma i ntena nc e Bypass eaton.com/epdu 1.800.356.5794 15 EFLXI3000R-PDU1UIEC EFLX2000R-PDU1UL EFLX1500R-PDU1U FlexPDU mounted with 2U UPS EHBPL1500R-PDU1U.
Monito red ePDUs EA TON C ORPORA TION Enclosure Power Distribution Units 16 Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101MI0U233 V70NA1-N-SS-109 5-15P None 1.44 MI 9 0U (24) 5-15R 66 x 2.
eaton.com/epdu 1.800.356.5794 17 Monito red ePDUs PW105MI0U255 PW309MI0U248 PW309MI0U250 PW317MI0U222 PW306MI0U247 PW309MI0U256.
EA TON C ORPORA TION Enclosure Power Distribution Units 18 Monito red ePDUs Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101MI1U221 T982A1-N-SS-109 5-15P (1) 15A 1.44 MI 9 1U (12) 5-15R 1.
eaton.com/epdu 1.800.356.5794 19 Adv a nced Mo nitored ePDUs Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW105AM0U411 VPC3695-3794 L6-30P (2) 20A 5.76 AM 9 0U (14) C13, (2) C19 66 x 2.
S w itched ePDUs EA TON C ORPORA TION Enclosure Power Distribution Units 20 Switched ePDUs Eaton switched ePDU provides remote power monitoring of both voltage and current and provides outlet level control for on/off/reboot.
eaton.com/epdu 1.800.356.5794 21 S w itched ePDUs PW101SW0U224 PW103SW0U152 PW105SW0U154 PW309SW0U178 PW102SW0U150 PW103SW0U153.
EA TON C ORPORA TION Enclosure Power Distribution Units 22 Ea ton A uto mat ic T rans fer S witches Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PWA TSS515002 T2235-A1-NNB09S (2) 5-15P None 1.
Ea ton A uto mat ic T rans fer S witches eaton.com/epdu 1.800.356.5794 23 PWA TSS515002 Front view Rear view PWA TSL630006 Front view Rear view PWA TSL530007 Front view Rear view PWA TSSC20001 Front v.
EA TON C ORPORA TION Enclosure Power Distribution Units 24 Rack Power Module The Rack Power Module (RPM) delivers up to 36 kW (hard wire option required, BladeUPS connector limits to 12kW) of power to loads of various voltages, power cords and layouts.
General ePDU Environmental Specifications • Operating T emperature is 0 to 50˚ C • Storage T emperature is -40 to 70˚ C • Altitude Maximum 10,000 ft. • Relative Humidity is 95% max non-condensing The IEC Advantage: The IEC 60320 and IEC 60309 connectors described below are the most commonly specified.
P o we r Cables and Ac c esso r ies Optional Sensors SENSOR - T1-10 (1) T emperature Sensor , 10’ Cable SENSOR - T2-10 (2) T emperature Sensor , 10’ Cable each SENSOR - T1H1-10 (1) T emperature an.
Mounting Brackets Are Detachable With Several Mounting Options Shown Benefits of vertical mounts Eaton ePDUs can be mounted vertically , allowing you to save valuable space. Y ou can mount them vertically in rack side pockets, rear channels – or on a wall, which allows you to save traditional U space for IT equipment.
UNITED ST A TES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. T oll Free: 1.800.356.5794 eaton.com/epdu CANADA Ontario: 416.798.0112 T oll Free: 1.800.461.9166 LA TIN AMERICA South Cone: 54.11.4124.4000 Brazil: 55.11.3616.8500 Andean & Caribbean: 1.
Een belangrijk punt na aankoop van elk apparaat Eaton 010-0027 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Eaton 010-0027 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Eaton 010-0027 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Eaton 010-0027 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Eaton 010-0027 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Eaton 010-0027 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Eaton 010-0027 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Eaton 010-0027 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.